TT and TN system distribution lines type A leakage current operated protective residual relay monitors
Negotiable
Min.Order:1
Type | Function | Installation |
ASJ10-LD1C | AC-type residual current measurement; Alarm prompt of current crossing line; Rated residual operating current can be measured; Limit non-driving time can be set; Two sets of relay output; With local and remote “test” and “reset” functions. | (DIN 35mm) |
ASJ10-LD1A | A-type residual current measurement; Current percentage light column display; Rated residual operating current can be measured; Limit non-driving time can be set; Two sets of relay output (settable)note 1; With local and remote “test” and “reset” functions. | |
ASJ10L-LD1A note2 | A-type residual current measurement; Rated residual operating current can be measured; Limit non-driving time can be set; Two sets of relay output (settable); Transformer breakage alarm can be set; Pre-alarm value can be set; Return value can be set. With on-site display, remote "test", "reset" LCD display, 25 event records. | |
ASJ20-LD1C | AC-type residual current measurement; Alarm prompt of current crossing line; Rated residual operating current can be measured; Limit non-driving time can be set; Two sets of relay output; With local and remote “test” and “reset” functions. | (48*48) |
ASJ20-LD1A | A-type residual current measurement; Current percentage light column display; Rated residual operating current can be measured; Limit non-driving time can be set; Two sets of relay output (settable)note 1; With local and remote “test” and “reset” functions. |
Technical Parameter | Indicator | ||||
AC type | A type | ||||
Power supply | Voltage range | AC110V、AC220V (±10%) | AC/DC85~265V | ||
Power dissipation | ≤5W | ||||
Input | Rated residual operating current I△n | 0.03、0.1、0.3、0.5(A) | 0.03、0.05、0.1、0.3、0.5、1、3、5、10、30(A)note 3 | ||
Limit non-driving time △t | 0.1、0.5(s) | 0、0.06、0.1、0.2、0.3、0.5、0.8、1、4、10(s)note 4 | |||
Rated residual non-operating current I△no | 50%I△n | 50%I△n | |||
Performance characteristics | Sinusoidal AC | Sinusoidal AC and pulsating DC | |||
Frequency | 50Hz±5Hz | 50Hz±5Hz | |||
Operating range | -20% ~ -10%I△n | -20% ~ -10%I△n | |||
Output | Output mode | One is normally open and another is for transformation | One is normally closed or open, and another is for transformation | ||
Contact capacity | 5A 250VAC 5A 30VDC | AL1:8A 250VAC; 5A 30VDC AL2:6A 250VAC; 5A 30VDC | |||
Reset mode | Local reset or remote reset | Local reset, remote reset or automatic reset | |||
Installation and use environment | Temperature | Run temperature:-20℃ ~ +55℃,Storage temperature:-30℃ ~ +70℃ | |||
Humidity | ≤95%RH,no condensation, and no corrosive gas places | ||||
Elevation | ≤2000m | ||||
Class of pollution | Grade three | ||||
Installation category | Type Ⅲ |