V-Sorb 2800P BET surface area and micropore analyzer
V-Sorb 2800P BET surface area and micropore analyzer
V-Sorb 2800P BET surface area and micropore analyzer

V-Sorb 2800P BET surface area and micropore analyzer

USD $10000 - $30000 /Set

Min.Order:1 Set

Supply Ability:
30 Set / Sets per Month
Port:
Shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
1 days

Quick Details View All >

Brand Name:
Gold APP Instruments
Place of Origin:
China
Model Number:
V-Sorb 2800P

Gold APP Instruments Corporation Limited

Business license
Business Type: Manufacturer
Beijing China
Main Products: BET surface area analyzer ,pore size distribution analyzer ,helium density analyzer ,high pressure volumetric analyzer ,physisorption analyzer ,gas adsorption analyzer

Product Details

 

V-Sorb 2800P BET surface area and micropore analyzer introduction

 

V-Sorb 2800P BET surface area and micropore analyzer uses static volumetric adsorption principle, be designed with 2 analysis stations and 2 pretreatment stations. The pretreatment stations and analysis stations are separated, can work simultaneously and independently. All setting can be done through software interface, easy understanding operations can make all learners to fully master it within 1 days. This model mainly be used for research work like for universities and institutes, can be used for determine nanomaterials surface area, mesopore and micropore data.

 


V-Sorb 2800P BET surface area and micropore analyzer specifications

 

1.     Analysis Ability: volumetric adsorption/ desorption isotherms, BET (Brunauer-Emmett-Teller) surface area, Langmuir surface area, average particle diameter estimation, t-plot external surface area, BJH (Barrett-Joyner-Halenda) total pore volume and pore size distribution, t-plot, MP, HK (Horvath-Kawazoe), SF (Saito-Foley), DA (Dubinin-Astakhov), DR (Dubinin-Radushkevich) micropore etc.

2.     Measuring Ranges: 0.01 m2/g (by nitrogen)/ 0.0005m2/g (by krypton) to no known upper limit (specific surface area); 0.35 to 500nm (pore size)

3.     Accuracy: repeatability errors within 1%

4.     Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control system, greatly reduce the dead volume; enhance pore size distribution analysis resolution

5.     Coolant Level Prober: V-Sorb original coolant level control system with temperature probe, ensure the coolant level unchanged when compares with sample cells

6.     Sample Pretreatment: the pretreatment be controlled by software, has a start time preset function can realize unattended operation at night, much improve working efficiency

7.     Sample Stations: 2 analyzing and 2 pretreatment/degassing stations work simultaneously and independently

8.     Pressure Transducer: branded pressure transducers supports low P/Po point determination, 1000 and 1Torr dual transducers

9.     Partial Pressure: P/Po controllable accuracy range is 5x10-6 - 0.998

10.  Ultimate Vacuum: 4x10-2Pa (3x10-4Torr)

11.  Vacuum Pump: built-in vacuum pump be controlled by software can auto control pump start/stop  

12.  Adsorbate Gas: high purity N2, Ar, Kr, CO, CO2 etc. non-corrosive gases area optional

13.  Data Reduction: Windows-based software, perfect versatility, produced full featured and multi-model reports

 

 

V-Sorb 2800P BET surface area and micropore analyzer technical features

 

A: Vacuum System

1.     Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.

2.     Modularity design can configure as customer requests, also be benefit for future upgrading and maintenance.

 

 

B: Control System

1.     Industry used programmable solenoid valve system, strong anti-interference ability, convenient for installation and uninstallation.

2.     Separated analysis and pretreatment manifolds can prevent foreign matter to contaminate analysis manifolds during sample pretreatment.

 

C. Measures for Improving Accuracy

1.     Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).

2.     1Torr and 1000Torr dual pressure transducers, sectional measurement in pressure range can reduce errors in low vacuum, 1Torr pressure transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%).

3.     Unique monolithic manifolds system, decrease connecting points and reduce leak rate apparently.

4.     Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume.

 

 

 

Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.


Contact Supplier

Mr. Andy manager Chat Now
Mobile
86-18201085158
Skype
Gold-APP-Instruments
Address
haidian Beijing
Whatsapp
0086-18201085158

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Measuring & Analysing Instrument Stocks
Categories