SIEMENS QRA53.G27  UV flame detector

SIEMENS QRA53.G27 UV flame detector

USD $1 - $635 /Piece

Min.Order:1 Piece

Supply Ability:
1 Piece / Pieces per Month
Payment Terms:
T/T

Quick Details View All >

Brand Name:
SIEMENS
Place of Origin:
Germany
Model Number:
QRA53.G27

Shanghai Pingkai Automation Equipment Co., Ltd

Business license
Business Type: Trading Company
Huzhou Zhejiang China
Main Products: PLC , frequency converter ,combustion controller ,actuator , touch screen ,Cable ,IPC ,numerical control ,Switch ,soft starter ,Full-digital DC speed regulating device

Product Details

Siemens flame detector


Siemens original stock, infrared photoelectric eye QRI2 detects infrared, used to detect yellow flames, that is, to detect infrared in flames, and can be used for fuel flame safety detection. QRI2A2.B180B is used in conjunction with Siemens program controllers for large burners, and can operate continuously or intermittently.


Infrared flame detection.


QRI2B2.B180B Siemens Flame Detector


Flame signal amplifier.


There are two types of detection: frontal detection and side detection.


Automatic inspection function.


Not limited by the load of the burner.


Not limited by operating mode.


Installation, assembly, and service work must be completed by professional personnel


Before making any circuit changes within the connection area of the detector, isolate the equipment from the main power supply (all two levels disconnected).


Provide appropriate protection for connecting terminals to ensure they are not exposed to the hazards of electric shock. Check and confirm that the wiring is connected correctly.


Check and confirm that the wiring is connected correctly. Halogen lamps, welding equipment, special lighting fixtures, or ignition sparks may generate sufficient radiation to ignite the UV unit of the detector. X-rays and gamma rays can also cause erroneous flame signals.


Falling or hitting can affect safety functions. Such detector units cannot operate, even if their appearance appears to be damaged at all.


The ultraviolet flame detector is designed for Siemens burner control device to monitor oil gas flame and ignition spark. In order to ensure the free operation of the burner, these detectors continuously monitor the intensity of UV radiation from the burner flame during each half cycle, providing signal current for the control system.


The UV unit of the detector is located behind the rotating baffle at the front end of the detector tube, which is connected to the casing through a flange. Quartz glass windows protect pipes and blinds from dust entry. A hard shell accommodates a stepper motor that drives the shutter and electronic devices that control the shutter.


High sensitivity, the shell is made of die-cast aluminum. The UV flame detector is designed for use in Siemens burner controllers for monitoring gas or oil flames.


Flame protection devices, approved for continuous operation, are used to monitor oil and gas flames in applications with ionization probes and photocell detectors RAR9.


Use UV flame detector QRA2/QRA2M/QRA4/QRA4M/QRA10/QRA10M intermittent operation mode for flame protection.


UV flame detector, normal sensitivity, with flange/clamp UV flame detector is designed for Siemens burner controller, for monitoring gas or oil flame.


Installation precautions


Always run the high-voltage ignition cables separately, while observing the possible distance between the detector and other cables from the electrical connection of the flame detector. It is important to achieve actual non-interference and lossless signal transmission:


• Do not run the detector cable together with other cables - the line capacitance reduces the size of the flame signal - use a separate cable


Observe the allowable length of the detector cable (see Using Burner Control)


The connecting wire must pass through the protective tube (made of plastic or grounded metal)




Shanghai Pingkai Automation Equipment Co., Ltd. is specialized in the sales of industrial control automation products, system integration, electrical equipment sales, and electromechanical equipment sales.


Siemens Programmable Controller S7-200CN ET-200 S7-200 S7-300 S7-400 S7-1200 S7-1500 smartS7-200


Siemens touch screen OP77-TP series MP277 MP377 TD200-TD400C


Siemens Communication Accessories DP Cable Ethernet Cable DP Connector Communication Card


Siemens motor V60-V80 servo motor 1FT servo motor Bede motor 1FK motor


Siemens frequency converter V10 series MM440 series G110 series G120 series


Siemens CNC system 810D system 840D system 808D 8404DSL


Siemens frequency converter series: MM420, MM430, MM440, G110, G120. MIDASTER series


Siemens fully digital DC speed control device 6RA23, 6RA24, 6RA28, 6RA70, 6SE70 series


Siemens actuators, burners, controllers, electric eyes, flame detectors, modules, operation panels, etc


Siemens SQN, SQM, AGG, LFL, LME, LMV, QRA, SKP, VGD, VGF, VRD and other series products




LAE10- Flame control device, liquid fuel with RAR, AC230V


LFS1.21A2- LFS1.21A2 Flame Control Device


LFS1.21A2- LFS1.21A2 Flame Control Device


QRA2- UV flame detector, normal sensitivity, without flange/fixture


QRA2M-UV flame detector, high sensitivity, no flange/clamp


QRA4. U - UV flame detector, for pipeline installation, normal sensitivity (United States)


QRA10.C-UV flame detector, normal sensitivity, shell made of die cast aluminum


QRA10M. C-UV flame detector, high sensitivity, shell made of die-cast aluminum


QRA53. E17- UV flame detector, continuous operation, normal sensitivity, 125mm, AC110V


QRA53. E27- UV flame detector, continuous operation, normal sensitivity, 125mm, AC230V


QRA53. G27- UV flame detector, continuous operation, normal sensitivity, 125mm, AC230V


QRA55.E17- UV flame detector, continuous operation, normal sensitivity, 69mm, AC110V


QRA55.E27- UV flame detector, continuous operation, normal sensitivity, 69mm, AC230V


QRA55.E27 - UV flame detector, continuous operation, normal sensitivity, 69mm, AC230V


QRA73.A17- UV flame detector, normal sensitivity, detector tube length 125mm, AC120V


QRA73.A27- External flame detector, normal sensitivity, detector tube length 125mm, AC230V


QRA75.A27- UV flame detector, normal sensitivity, detector tube length 69mm, AC230V


QRA75.A17- UV flame detector, normal sensitivity, detector tube length 69mm, AC120V


QRI2A2.B180B - Infrared flame detector, front, cable 180cm, peeling+ferrule


QRB1A-A070B70A2 Photoresistive Flame Detector, Normal, Shell 50mm, Cable 70cm, Stripping 70mm


QRI2B2.B180B-Infrared Flame Detector, Horizontal, Cable 180cm, Stripping+Bushing



Contact Supplier

Mr. Ms. Cai manager Chat Now
Telephone
86-136-17190750
Mobile
86-13617190750
Address
Wuxing District Huzhou,Zhejiang

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~