Product Description
FC51 Frequency Converter
Specification
Mains supply (L1, L2, L3) | ||
Supply voltage | 1 x 200–240 V ±10%, 3 x 200–240 V ±10% 3 x 380–480 V ±10% | |
Supply frequency | 50/60 Hz | |
Displacement Power Factor (cos φ) near unity | (> 0.98) | |
Switching on input supply L1, L2, L3 | 1–2 times/min. | |
Output data (U, V, W) | ||
Output voltage | 0–100% of supply voltage | |
Output frequency | 0–200 Hz (VVC+ mode) 0–400 Hz (U/f mode) | |
Switching on output | Unlimited | |
Ramp times | 0.05–3600 sec | |
Digital inputs | ||
Programmable inputs | 5 | |
Logic | PNP or NPN | |
Voltage level | 0–24 V | |
Maximum voltage on input | 28 V DC | |
Input Resistance, Ri | Approx. 4 k | |
Pulse inputs | ||
Programmable pulse inputs | 1 | |
Voltage level | 0–24 V DC (PNP positive logic) | |
Pulse input accuracy (0,1–110 kHz) | Max. error: 0.1% of full scale | |
Pulse input frequency | 20–5000 Hz | |
Analog input | ||
Analog inputs | 2 | |
Modes | 1 current/1 voltage or current | |
Voltage level | 0 – 10 V (scaleable) | |
Current level | 0/4 – 20 mA (scaleable) | |
Analog output | ||
Programmable analog outputs | 1 | |
Current range at analog output | 0/4–20 mA | |
Max. load to common at analog output | 500 | |
Accuracy on analog output | Max. error: 1% of full scale | |
On-board power supply | ||
Output voltage | 10.5 ± 0.5 V, 24 ± 0.5 V | |
Max. load (10 V) | 25 mA | |
Max. load (24 V) | 100 mA | |
Relay outputs | ||
Programmable relay outputs | 1 | |
Max. terminal load | 240 V AC, 2 A | |
Fieldbus communication | FC Protocol, Modbus RTU | |
Cable lengths | ||
Max. motor cable length, screened (shielded) | 15 m | |
Max. motor cable length, unscreened (unshielded) | 50 m | |
Surroundings/ External | ||
Enclosure | IP 20 | |
Vibration test | 0.7 g | |
Max. relative humidity | 5%–95% (IEC 721-3-3; Class 3K3 (non-condensing) during operation | |
Aggressive environment | (IEC 721-3-3), coated class 3C3 | |
Ambient temperature | Max. 50° C | |
24-hour average | Max. 40° C | |
Approvals | CE | |
Protection and features | ||
• Electronic thermal motor protection against overload | ||
• Temperature monitoring of the heat sink protects the drive from overheating | ||
• The drive is protected against short-circuits on motor terminals U, V, W | ||
• The drive is protected against earth fault on motor terminals U, V, W |
Packing & Delivery
FAQ
Q: Do you support customized manufacturing?
A: Yes,we can customized manufacturing according to customer's requirment. We support to OEM your own company display interface and logo.
Q: How long is your delivery time?
A: Generally it is 3-5 days if the goods are in stock. or it is 5-10 days if the goods are not in stock, it is according to
quantity.10-20 days if customized manufacturing.
Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample with sample price.
Q: What is your terms of payment ?
A: Payment<=2000USD, 100% in advance. Payment>=1000USD, 70% T/T in advance ,balance before shippment. If you have another question, pls feel free to contact us as below
A: Yes,we can customized manufacturing according to customer's requirment. We support to OEM your own company display interface and logo.
Q: How long is your delivery time?
A: Generally it is 3-5 days if the goods are in stock. or it is 5-10 days if the goods are not in stock, it is according to
quantity.10-20 days if customized manufacturing.
Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample with sample price.
Q: What is your terms of payment ?
A: Payment<=2000USD, 100% in advance. Payment>=1000USD, 70% T/T in advance ,balance before shippment. If you have another question, pls feel free to contact us as below