TIME 2190 with A/B scan Ultrasonic Thickness Gauge
Negotiable
Min.Order:1
TIME 2190 with A/B scan Ultrasonic Thickness Gauge
1.Product description
TIME®2190 is the latest high-end ultrasonic thickness gauge developed by TIME Group Inc. It adopts pulse refection principle, that is, the transducer sends ultrasonic pulses to travel through the test object and receives the reflection pulse from the backwall of the object. TIME2190 can nondestructively monitor the thickness of almost any material like metals, plastics, composites, fiberglass, ceramics, and glass with A scan/B scan. It is used to test the wall thickness and corrosion of various kinds of plates, pipes, boilers, vessels across industries like metallurgy, shipbuilding, machinery, chemical, aerospace, power, automotive, oil and gas, manufacturing and others.
2.Features
A-scan waveform can be displayed for echo analysis and measurement of complex workpiece; Compatible with many types of transducers, both single and dual element transducers; Users can set blanks to shield aftershocks or clutter;
Echo-echo measures the true metal thickness with ignoring the thickness of coating layer.
Thru-coat technology measures metal and nonmetallic coating thickness. Signal auto-amplification function (centered display of the detected echo); Adjustable voltage variable pulse width square wave pulse generator;
Single value B-scan display function;
Users can turn on fast measurement mode up to 20 times per second;
Standard Delivery |
|
Optional Accessory |
Main unit |
1 |
Communication cable |
5MHz dual crystal probe |
1 |
Standard test block |
Couplant |
1 |
1MHz single crystal probe |
|
|
TSTU32 Probe |
|
|
5MHz single crystal probe |
|
|
15MHz single crystal probe |
3.Specification:
Measuring range |
0.25~500mm |
Display resolution |
0.001 mm, 0.01 mm or 0.1 mm |
Sound velocity range |
508 m/s~18699m/s |
Repeatability |
5M probe and above: 0.03mm |
Display screen |
Color TFT LCD, 320x240 pixels |
Gain range |
0-99dB, 1dB step |
Pulse Generator |
Adjustable Square Wave Pulse Generator |
Emission voltage |
60V, 110V, 150V, 200V optional |
Emission pulse width |
varies with transducer frequency |
Frequency range |
0.5 Mhz~20Mhz |
Measurement rate |
standard (4Hz), fast (20Hz) |
Transducer settings |
10 sets of fixed setting and 22 sets of custom setting |
Data Storage |
500 data files, each capable of storing 1000 measurements and waveforms |
Interface |
USB |
Power |
three AA battery or NiMH batteries |
Working temperature |
0~40℃ |
Weight (g) |
360g |
Dimension |
187mm×87 mm×43 mm |
4.Transducer Measurement Range:
Transducer Type |
Measuring Range (steel) |
Indication Error |
Using Mode |
5MHz dual element narrow pulse transducer |
1.2~225.0mm |
H<10mm, ±0.05mm; |
Standard |
5MHz single element contact transducer |
5.0~225.00mm |
H<10mm, ±0.05 mm; |
Standard |
TSTU32 2MHz Double element transducer |
3.0~300.00mm |
H<10mm, ±0.1 mm; |
Standard |
1MHz single element contact transducer |
10.~500.00mm |
H<10mm, ±0.1 mm; |
Standard |
15MHz Single element delay block transducer: |
3.0mm~20.0mm |
H<10mm, ±0.05 mm; |
Interface-echo |