High teperature high frequency dynamic/static pressure transducer, MEMS pressure sensor P81
USD $200 - $500 /Piece
Min.Order:1 Piece
Industrial OEM Microfused pressure transducer, high stability low cost pressure transmitter P76
PE General Purpose dynamic pressure sensor for high frequency P90:
130℃ Bioreactor Medical steam sterilizer Application high temperature pressure transducer
Non-corrosive Radar level meter 120/80GHz RL805 for Corrosive applications
Non-corrosive Radar level meter 120G/80GHz RL807 for Food and Medical applications
SensStar deign and provide P81 series pressure transducer, P81 high frequency response pressure sensor utilizes the excellent elastic mechanical properties of silicon, adopts micromachining technology, flush packaging structure, and integrated silicon diaphragm sensing element. Its effective size is small, its dynamic frequency response is extremely high (up to 1MHz), and it can obtain broadband response as low as zero frequency and as high as close to natural frequency, and it has rise time as low as microseconds, Its comprehensive performance is better than that of piezoelectric dynamic pressure sensor. This series of products are suitable for military engineering, chemical explosion test, petroleum exploration and logging, materials, mechanics, civil engineering, geotechnical mechanics, trauma medicine, hydraulic power mechanical test and other scientific tests and modern instruments, and are the first choice for dynamic pressure waveform measurement. Its performance index has reached the international advanced level, which can completely replace the similar foreign products. Optional pen style shock wave pressure sensor.
-MEMS pressure sensitive devices based on SOI
-Flush package, good dynamic characteristics
-Wide range of pressure measurement
-Good long-term stability
Dynamic Frequency response | up to 1MHz, 10KHz , 50KHz,100KHz,200KHz available | |||||
measure medium | Various liquids or gases compatible with silicon, stainless steel and glass | |||||
Pressure Range | 0~10KPa……60MPa | |||||
Nonlinearity | 0.05%FS | 0.15%FS | 0.3%FS | 0.5%FS | ||
Hysteresis, Repeatability | 0.03%FS | 0.1%FS | 0.2%FS | 0.3%FS | ||
Accuracy | 0.1%FS | 0.2%FS | 0.5%FS | 1%FS | ||
Applied Pressure (proof) | ≥200%FS | |||||
Long term stability | better than 0.2%FS/Year | |||||
Electrical | ||||||
Full scale output | 80mV±20mV | |||||
Zero output | ≤±2mV | |||||
Power supply | 1.5mA,5mA or 9V | |||||
Connect | M20, 1/4NPT, Self locking structure | |||||
insulation resistance | 100MΩ(50VDC) | |||||
Environmental | ||||||
zero temperature | 0.03%FS/℃ (typical) | |||||
Sensitivity temperature coefficient | 0.03%FS/℃ (typical) | |||||
Compensation temperature | 0~70℃ | -25~50℃ | 25~125℃ | 25~175℃ | ||
Storage | -40℃~125℃ | |||||
Humidity | 0%~85% RH | |||||
Structure | ||||||
Pressure Connect | M20×1.5,M12×1,others | |||||
Materials | 1Cr18Ni9TI | |||||
Weight | <150g |