CF1900/CF1200 Cross Fluted Film Fill Media For Cooling tower Replacement Fill Patterns in fill
CF1900/CF1200 Cross Fluted Film Fill Media For Cooling tower Replacement Fill Patterns in fill
CF1900/CF1200 Cross Fluted Film Fill Media For Cooling tower Replacement Fill Patterns in fill
CF1900/CF1200 Cross Fluted Film Fill Media For Cooling tower Replacement Fill Patterns in fill
CF1900/CF1200 Cross Fluted Film Fill Media For Cooling tower Replacement Fill Patterns in fill

CF1900/CF1200 Cross Fluted Film Fill Media For Cooling tower Replacement Fill Patterns in fill

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Hebei Lanyu Rubber & Plastic Products Co., Ltd.

Business Type: Distributor/Wholesaler
Main Products: , , ,

Product Details

Product Description

CF1900/CF1200 Cross Fluted Film Fill Media For Cooling tower Replacement Fill Patterns in fill

If you’ve never worked in a cooling tower you might be tempted to think that the heart of a water cooling tower is the water. While the purpose of a cooling tower revolves around water, the true heart of any cooling tower is the fill.
Fill, or wet deck or surface, is a medium used in cooling towers to increase the surface area of the tower. Increased surface area allows for maximum contact between the air and the water, which allows for greater evaporation rates.
Splash vs.
Film Fill
There are two basic types of fill: splash fill and film fill. Splash fill is designed to interrupt the water and cause, as the
name suggests, splashing. Film fill, on the other hand, is made up of sheets of material that the water travels across. Pieces of fill are assembled together to create larger blocks which, in turn, are used to create various thickness and heights to suit the particular cooling tower they will be used for.
OW cooling tower fill belong to counter flow cooling tower fill, it is glued together to be a block which is full of the middle bottom in tower. The thickness are 0.28mm 0.38mm; the width are 150mm,305mm,610mm; the length are 1200mm,1800mm,2000mm,2400mm;
The pitch distance are 12mm,15mm,19mm and 25mm.The pitch 12mm 19mm is normal size. The cooling tower fill is also called CF1900,CF1200. It means the Trickling Filter Media will be glue to be a block which size is 305x305x1200mm. The honeycomb is in the vertical direction to make sure the cool air meet the hot water directly.
Name
OW cooling tower fill PVC cooling tower filler plastic sheet for cooling tower
Material
PVC, PP
Nomal Size
305mmx305mmx1200mm,150*305*1200mm,610*305*1200mm
Fluted size
12mm,19mm
Shaping mode
Plastic extrusion mould
Sheet thickness
0.28-0.37MM ,also can be customized
Packing Details
In bundle, wooden pallet or as requested
Sample Time
1-2days
Production Date
Within 20days
Flutes
Patterns in fill, usually ridges or wrinkles, are called channels or flutes. Flutes are, typically, designed so that they force the water to take the longest route along them possible. Smaller flutes are more cost effective because they allow for more capacity per cubic foot. Larger flutes, however, are good for dirty water applications (like steel mills) because larger flutes become clogged less often than smaller flutes in these types of applications. Larger flutes sacrifice efficiency, but they allow dirtier water to be processed. In extremely dirty applications bar type fill is used. Bar type fill allows for much larger debris to be passed through the cooling tower because the fill takes the form of splash bars throughout the tower. Although this is the least effective fill, bar type fill allows dirty water to be processed and is easier to clean.
Advantages of Film Fill
We can’t speak for all cooling tower fill, but our fill offers a number of advantages including:
* Sturdy PVC construction
* Highly efficient
* Self-extinguishing for excellent fire rating
* Easy, quick installation
* UV-protected
Detail of cooling tower fill PVC cooling tower filler plastic sheet for cooling tower fill

610mm 19pitch width OW cooling tower fill/ film fill packing

915mm 19pitch width OW cooling tower fill/ film fill packing
We have different series and many designs for your options. If you need sample for reference, we can arrange for you.We can also customize the design, if you can offer us a sample or drawing, we can build new mol

The block picture of OW cooling tower fill/ film fill packing
FOQ
Q: Are you trading company or manufacturer ?
A: We are manufacturer with our own factory.

Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. Or it is 15-20 days if the goods are not in stock, it is according to
quantity.

Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge. And the freight cost will on the buyer's side.

Q: What is your terms of payment ?
A: Payment<=USD1000, 100% in advance. Payment>=USD1000, 30% T/T in advance ,balance before shipment.