Hangzhou huite Technology FBUS FBMGS5100 Industrial grade RS232 / 485 / 422 to Ethernet, TCP to RTU, MODBUS gateway, wide voltage 12-48v, power supply
CNY 500 - 530 /Piece
Min.Order:1000 Pieces
hangzhou huite Technology CO.Ltd
Hangzhou huite Technology FBUS Industrial RS-422 / 485 to Ethernet module
Hangzhou huite Technology FBUS NE-FBPORT2110S Industrial RS-232 to Ethernet module
Hangzhou huite Technology FBUS NE-FBPORT2100T Industrial RS-232 to Ethernet module
Hangzhou huite Technology FBUS NE-FBPORT2110A Industrial RS-422 / 485 to Ethernet module
Hangzhou huite Technology FBUS NE-FBPORT2120A Industrial RS-422 / 485 to Ethernet module
Modbus is one of the most commonly used protocols in the field of industrial automation. It supports the traditional RS-232 / 422 / 485 serial port equipment and the newly developed network equipment. Fbmgs5100 is a standard model of 1-way MODBUS gateway device, with 1 RS-232 / 422 / 485 serial port. The serial port working mode can be set freely. It supports the access of 16 TCP clients and the connection of 32 TCP servers. It can complete the protocol conversion from Modbus TCP to Modbus RTU / ASCII.
characteristic:
Integrated Modbus TCP and Modbus RTU / ASCII network
Each serial slave port supports up to 31 Modbus RTU / ASCII slave devices
The gateway device can connect up to 32 Modbus TCP servers (slave)
Support 10 / 100M network adaptation and DHCP
The serial port can be set to RS-232, RS-422 or RS-485 mode
Up to 16 Modbus TCP clients (Master) are allowed to connect to the gateway device
The baud rate of the serial port is up to 921.6kbps
The path can be automatically selected from the ID table
Ethernet interface
Rate: 10 / 100 Mbps, adaptive MDI / mdix
Interface: RJ45 8-pin
Protection: built in 1.5kV electromagnetic isolation
serial interface
Serial port type: male DB9
Serial port signal: RS-232: TXD, RXD, RTs, CTS, DTR, DSR, DCD, GND
RS-422:Tx+、Tx-、Rx+、Rx-、GND
RS-485 (2-wire):Data+、Data-、GND
RS-485 (4-wire):Tx+、Tx-、Rx+、Rx-、GND
Serial communication parameters
Check bits: none, even, odd, space, mark
Data bits: 7, 8
Stop position: 1, 2
Flow control: RTS / CTS, Xon / XOFF, DTR / DSR
Transmission rate: 50 bps to 921.6 kbps
Serial port protection
Provide 15 kV ESD linear protection and surge protection for all signals
Power linear protection
4 KV Burst (EFT),EN61000-4-4
2 KV Surge,EN61000-4-5
Power demand
Power input: 12 ~ 48 VDC, dual power redundant input.
Power interface type: terminal block
Tel: 13336062152 / 13867426148 (same wechat number);
EMAIL: ffy@anyfbus.com Welcome to inquire.