HYDRAN M2 GE Online transformer monitoring equipment
HYDRAN M2 GE Online transformer monitoring equipment
HYDRAN M2 GE Online transformer monitoring equipment
HYDRAN M2 GE Online transformer monitoring equipment
HYDRAN M2 GE Online transformer monitoring equipment

HYDRAN M2 GE Online transformer monitoring equipment

USD $100 - $200 /Pound

Min.Order:100 Pounds

Supply Ability:
100 Pound / Pounds per Month
Payment Terms:
T/T

Quick Details View All >

Brand Name:
GE
Model Number:
HYDRAN M2

Xiamen xiongba e-commerce Co., Ltd. Zhangzhou Branch

Business license
Xiamen Fujian China
Main Products: ABB ,GE ,BENTLY ,TRICONEX ,HIMA ,HONEYWELL ,EMERSON ,REXROTH

Product Details

HYDRAN M2 GE Online transformer monitoring equipment

HYDRAN M2 GE Online transformer monitoring equipment

Our Email: 2235954483@qq.com

contact number:13313705507

contacts:HE


Setting current for overload, locked rotor etc. Setting I

e 9,0 ...1207 A divided into 19 overlapping ranges. See table, page 40

Time for start ramp Start Ramp 1 ... 30 s, 1 ... 120 s (Range depends on Start Range) 10 s

Time for stop ramp Stop Ramp 0 ... 30 s, 0 ... 120 s (Range depends on Stop Range) 0 s

Initial voltage for start ramp Init Volt 30 ... 70 % 30 %

End voltage for stop ramp End Volt 30 ... 70 % 30 %

Step down voltage Step Down 30 ...100 % 100 %

Level of the current limit. Current Lim 1.5 ... 7.0 x Ie 4.0 x I

e

Selection of Kick start Kick Start Yes, No No

Level of Kick start if selected Kick Level 50 ... 100 % 50 %

Time for Kick start if selected Kick Time 0.1 ... 1.5 s 0.2

Selectable range for start ramp Start Range 1 ... 30 s, 1...120 s 1 ... 30 s

Selectable range for stop ramp Stop Range 0 ... 30 s, 0 ... 120 s 0 ... 30 s

Overload protection Overload No, Normal, Dual Normal

Overload Class OL Class 10 A, 10, 20, 30 10

Overload Class, Dual type, Start Class OL Class S 10A, 10, 20, 30 10

Overload Class, Dual type, Run Class OL Class R 10A, 10, 20, 30 10

Type of operation for overload protection OL Op Stop-M, Stop-A, Ind Stop-M

Locked rotor protection Locked Rotor Yes, No No

Trip level for locked rotor protection Lock R Lev 0.5 ... 8.0 x Ie 4,0 x I

e

Trip time for locked rotor protection Lock R Time 0.2 ... 10 s 1.0 s

Type of operation for locked rotor protection Lock R Op Stop-M, Stop-A, Ind Stop-M

Underload protection Underload Yes, No No

Trip level fo

Contact Supplier

Ms. HE 2235954483@qq.com Chat Now
Mobile
86-13313705507
Address
Siming District Xiamen,Fujian

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~