Taijia Low Strain Integrity Testing Foundation Pile Dynamic Detector Pile Tester
Negotiable
Min.Order:1
P8100 Foundation Pile Dynamic Detector is used to assess the integrality of concrete pile and identify the extent and location of the pile detect by using the reflected wave method.
It can be used for testing perfusion pile and hammer pile and also for testing the exposed top surface of constructions such pillars.
The ZBL-P8100 is pile integrity tester provided with 2 channels of data acquisition and can acquire data from an accelerometer or an instrumented hammer or from two accelerometers.
1.High fidelity system design, to ensure that the original waveform distortion
2.True 24 bi A/D data acquisition, the rest waveform is more real, to avoid the noise and signal distortion caused by large floating point amplification
3.1MHz high speed data acquisition, the minimum sampling time resolution of 1μs,can provide more useful information, more conducive to the discovery of shallow defects;
4.Double channel design, allows use the special detection method
5. A new processing method of wavelet analysis, can be more accurate in complex situations of pile integrity judgement
6. Double injection molding, beautiful appearance, small volume, light weight;
7. Waterproof casing, anti shock design, adapt to the harsh environment
8.Semi transparent, high brightness, TFT color LCD screen, more clearly in the sun
Model | ZBL-P8100 |
Control Mode | A8 Embedded Platform |
Screen | 5.7inch, High Brightness, TFT color LCD screen |
Data Storage | ≥4GB |
Operation Mode | Key + touch screen |
Sentinel Magnify(time) | 1,2,5,10,20,50,100 adjustable |
A/D resoulution(bit) | A/D resoulution(bit) |
Sampling time intervals(μS) | 1~64000 adjustable |
Max length of sampling | 4096 |
Trigger | Signal trigger |
Noise voltage of the system(mV) | ≤1 |
Dynarnic Range(dB) | ≥184 |
Amplifier frequency range(Hz) | 10~10K |
Time value error | 4096 |
Time resolving power(us) | ≤10% |
Gain Error(dB) | ≤1% |
Work time(h) | >8 |
Number of channels | 2 |
Interference between the channels | ≤1% |
Transducer/Probe Sensitivity (Acceleration mode) (mv/g) | ≥100 |
Frequency range of Probe (Acceleration probe) (Hz) | 0.5~9000 |
Port | Double USB |
Wi-Fi | Yes |
Internal:Built-in Battery | |
External: 220VAC/DC | |
Temperature(℃): -10~+50 | |
Humidity (RH) :<90% |
ZBL-R630A is used to test the location of rebar in concrete, the thickness of the protective layer, and the diameter, orientationand distribution of rebar by using an electromagnetic induction method. It also can be used to test the distribution of magneticand conductor such as cables and metal pipes in non-magnetic medium and non-conducting medium
ZBL-R800 is a multi-functional integrated rebar detector which can be used for testing the thickness of protective layers, measuring the diameter, location, and distribution of rebar as well as for detecting the corrosion content of a rebar.
HT-225W+ digital test hammer with digital display and voice function, for the quick and easy determinationof the strength of concrete, and hardness of construction materials. Digital and voice functions allow fasterand greater number of test, leading to better quality tests.
Trade terms
1. 18 Month's Warranty.
2. Delivery time:3-7 working days after payments received
3. MOQ:1 set.
4. Service express company:TNT/DHL/FedEX.
5. We accept T/T, Western Union, PayPal & Secure Payment.
NO.5 Shanshui Yuan, High-tech Industrial Zone Dalian, China 116033
E-mail:info at
TEL:86-411-39685079
Whatsapp:+8615998537470
Skype:tmeasurement02
web:/