PROFIBUS DP-V1 ABCC-DPV1
1032 - 2252 /Piece
Min.Order:1 Piece
Temporal Ming sheng automation equipment co., LTD
Brand: PROFIBUS
Type:DP-V1 ABCC-DPV1
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
Port B is routed (via the module at J10) to the 25-pin DB25 connector marked SERIAL PORT 2 on the MVME162 front panel. Port B is also routed to a DB9 (on the MVME712x) or DB25 (on the MVME712M) connector on the MVME712 series transition module. It is identified there as Port 4. Although both ports are connected to the same Z85230 Port B, there are several considerations to keep in mind: ❏ On the MVME162 front panel, Port 2 can be connected to the TxC and RxC clock signals which may be present on the DB25 connector. These connections are made via header J12 on the MVME162 board (see Figures 2-3, 2-4, and 2-5 in Chapter 2). The TxC and RxC clock lines are also available at Port 4 on MVME712M transition modules. ❏ On MVME712x transition modules, Port 4 is hard-wired as an EIA-232-D DB9 DTE serial port. A ‘‘null modem’’ cable is necessary to use it as a DCE port. ❏ On MVME712M transition modules, Port 4 can be configured as either a DTE or DCE EIA-232-D serial port via jumper headers J19 and J18 on the MVME712M. Port 4 can also be connected to the TxC and RxC clock signals which may be present on the DB25 connector. These connections are made via header J15 on the MVME712M (see Figure 2-3, sheets 3-6 in Chapter 2). ❏ When Port B is configured as an EIA-530 interface, EIA-530 data transfers normally occur through serial port 2 on the MVME162 front panel.
The MVME712 series transition module should be disconnected from the MVME162. Although the signals are present at P2 (see Figure 2-5), the EIA-530 standard calls for a DB25 connector and balanced (not single-ended) lines; these are not supported by the P2 adapter and MVME712 series transition modules. System integrators who wish to use the EIA-530 signals at P2 must provide the appropriate connections. Figure 2-3 (sheets 3-6), Figure 2-4 (sheets 3-4), and Figure 2-5 in Chapter 2 illustrate the factory configurations available for Port B. Note that the port configurations shown in Figure 2-3, sheets 5 and 6 are not recommended for synchronous applications because of the incorrect clock direction.