SFS236C
USD $1206 - $2215 /Piece
Min.Order:1 Piece
Temporal Ming sheng automation equipment co., LTD
Brand:BACHMANN
Type:SFS236C
Origin:the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
Spare parts spare parts, the main DCS control system of PLC system and the robot system spare parts,
Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Add Event with Data Blocks (8000, 8001) Block 8000: Add Event with Data for Port 1 Block 8001: Add Event with Data for Port 2 The 8000-series blocks are similar to the 1000 and 2000-series blocks. The 8000-series blocks source the command data from the processor, instead of from the module’s database. Block 8000 or 8001: Request from Processor to Module Offset Description 0 Write Block ID: 8000 for Port 1 or 8001 for Port 2 event command with data request 1 Slave address of Modbus device to reach with the command request 2 Modbus function code to use with command (5, 6, 15 or 16) 3 Modbus address in slave device 4 Count value for operation- bit count for function 15 (1 to 800 points) and word count for function 16 (1 to 50 words or 1 to 25 float values). For functions 5 and 6, the count is assumed to be 1. 5 to 54 Data to be used by command 55 to (n-1) Spare Where n = 60, 120, or 240 depending on the Block Transfer Size parameter. Block 8000 or 8001: Response from Module to Processor Offset Description 0 Read Block ID: 8000 for Port 1 or 8001 for Port 2 event command with data request 1 Write Block ID: To be used by the processor in its next Write block. 2 Error Code for request: 0=no error -1=port is not enabled -2=port is not a master port -3=port is not active (enabled) -4=port busy with previous event command -5=invalid Modbus command -6=invalid point count for command
Get Event with Data Status Block (8100) Block 8100: Get Event with Data Status This block requests status data for Event with Data Commands. Block 8100: Request from Processor to Module Offset Description 0 Write Block ID: 8100 status data request for Event with Data Commands. 1 to (n-1) Spare Where n = 60, 120, or 240 depending on the Block Transfer Size parameter. Block 8100: Response from Module to Processor Offset Description 0 Read Block ID: 8100 status data for Event with Data Commands. 1 Write Block ID: To be used by the processor in its next Write block. 2 Event command status for Port 1: 0=No message active 1=Waiting to execute command 2=Command complete 3 Error code for last command executed for Port 1 4 Event command status for Port 2: 0=No message active 1=Waiting to execute command 2=Command complete 5 Error code for last command executed for Port 2