Syringe Needle Cone Joint Performance Comprehensive Test Instrument

Syringe Needle Cone Joint Performance Comprehensive Test Instrument

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Fuzhou Smartell Technology Co., Ltd.

Business Type: Distributor/Wholesaler
Main Products: , , ,

Product Details

Syringe Needle Cone Joint Performance Comprehensive Test Instrument

 

Syringe Needle Cone Joint Performance Comprehensive Test Instrument

Syringe needle cone joint performance comprehensive test instrument is based on "GB/T1962.1-2015 syringes, needles and other medical equipment 6% (the Luer) cone joint part one: general requirements" of the relevant terms and conditions and the design and manufacture, specially used for testing taper joint leakage, leakage, separation force, stress cracking performance of special test equipment, etc.

Syringe needle cone joint performance comprehensive test instrument is based on "GB/T1962.2-2001 (98) idt ISO594 - the syringes, needles and other medical equipment 6% the second part (the Luer) cone joint locking joint" relative clauses in the design and manufacturing, 6% (the Luer) specially used for testing taper joint leakage, leakage, separation of power, unscrew the torque, easy assembly, resistance wire, such as stress cracking performance of special test equipment.

The tester is composed of intelligent controller, LCD screen, stepping motor, stepping motor driver, transmission mechanism, sensor, fixture, printer, etc.

The screen adopts full Chinese/English menu display, double operation with touch screen and buttons, more convenient operation, more stable performance, setting, real-time display test force value, holding time, with full functions, clear display and other advantages.

 

Syringe Needle Cone Joint Performance Comprehensive Test Instrument Environment:

 

Working Temperature 5~40℃
Relative Humidity 45-80%
Power Supply: 220V ± 22V
Frequency : 50 HZ ± 1HZ

 Axial Force Range:20N~40N,The verification error shall not be greater than ±2% of the reading;

Torque Range:0.02N·m~0.16 N·m,The verification error is not greater than ±2.5% of the reading;

Internal pressure: 300kPa ~ 330kPa, verification error no more than ±2% of the reading.

 

 

 

Syringe Needle Cone Joint Performance Comprehensive Test Instrument

 

 Syringe Needle Cone Joint Performance Comprehensive Test InstrumentSyringe Needle Cone Joint Performance Comprehensive Test Instrument

Syringe Needle Cone Joint Performance Comprehensive Test InstrumentSyringe Needle Cone Joint Performance Comprehensive Test InstrumentSyringe Needle Cone Joint Performance Comprehensive Test InstrumentSyringe Needle Cone Joint Performance Comprehensive Test InstrumentSyringe Needle Cone Joint Performance Comprehensive Test InstrumentSyringe Needle Cone Joint Performance Comprehensive Test InstrumentSyringe Needle Cone Joint Performance Comprehensive Test Instrument

 