HY-300D Glass Beads Sterilizer
HY-300D Glass Beads Sterilizer

HY-300D Glass Beads Sterilizer

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Hangzhou Boyn Instrument Co., Ltd.

Business Type: Agent
Main Products: , , ,

Product Details

HY-300D Glass Beads Sterilizer

 

HY-300D Glass Beads Sterilizer

HY-300D Glass Beads Sterilizer

 

Product description: 

HY-300 glass bead sterilizer use a heated glass beads for small lab equipment for fast sterilization products. Sterilizers has compact design and effectively sterilize small solid metal and glassware within ten seconds.When glass beads are heated to about 300 , it can effectively destroy bacteria and spores.The model is usually used for forceps, scissors, forceps, scalpels, needles, ring vaccination and inoculation needle and commonly used in research labs.

 

Product Features

1, Compact appearance design, digital display temperature at real-time. It can be used in ultra clean workbench.

2, Stainless steel inner container, built-in high-performance heating element, high precision of temperature controller and overtemperature protection.
3, Inner temperature of container is equipped with high temperature sterilization bead can be heated to about 300
.
4, Small volume, light weight, simple operation, long working life.
5 Randomly configurate diameter 1.5 ~ 2.0 mm of glass beads.

 

Technical parameters

Model

HY-300

HY-300D

Temp. Control Range

100 ~300

100 ~300

Temp. Stability

≤±5

≤±5

Heating Speed

≤25min

≤25min

Heating Well Volume

40 x 80mm

40 x 150mm

Glass Beads Capacity

150g

150g

Cover Material

Stainless Steel

Stainless Steel

Insulation Material

Green Mineral Wool

Green Mineral Wool

Voltage

AC 220 / AC 110V, 50/60Hz

AC 220 / AC 110V, 50/60Hz

Power

120W

300W

Fuse

250V,2A/3A, 5×20

250V,2A/3A, 5×20

Dimension (WxDxH)

130 x 150 x 200mm

130 x 150 x 240mm

Net Weight

2kgs

2.5kgs

 

Attention:

1, with clean, dry glass beads filled in sterile container.The standard depth below the edge of stainless steel container about 2cm. Please don’t use other fillers or liquid contact to  container.

2. Turn on the power switch and take some time to heat.Then the vessel temperature can reach to the set temperature. Under the conditions of power turning on it will keep the internal temperature.

3. Don’t touch the glass beads or sterilization container before cooling! Avoid burns!

4, Insert the drying equipment needs to be sterilized to sterilized glass beads as much as possible  at least 10s.

5, Turn off the power switch and the closed the cover after finished to prevent dust and foreign matter.

6, Sterilized glass beads must be cleaned at least once per week. Should wait until the instrument cooled completely when getting out the glass beads.

7, Reuse after strictly clean and dry. (Get the glass beads out and clean with mild detergent soap, After rinsing ,it can be dried)

 

Please send inquiry>>

HY-300D Glass Beads Sterilizer

HY-300D Glass Beads Sterilizer

HY-300D Glass Beads Sterilizer

HY-300D Glass Beads Sterilizer

HY-300D Glass Beads Sterilizer

     If you need any detail packing information, please contact us>>

HY-300D Glass Beads Sterilizer

     If you have any question, please contact us>>

HY-300D Glass Beads Sterilizer

HY-300D Glass Beads Sterilizer

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Chemicals > Lab Supplies > Other Lab Supplies
Categories
Hi~