Lab scientific research pH EC conductivity ISE DO Temp orp portable multiparameter water analyzer
Negotiable
Min.Order:1
Lab pH EC conductivity ISE DO Temp orp portable multiparameter water analyzer
Multi-parameter water quality meter is one meter with several measuring unit. It can measure simultaneously pH/pX, Ion concentration, ion electrode potential (mV) value, Condutive (conductivity, TDS, salinity), DO (concentration and saturation) and temperature, etc.
It is suitable in the field of disease control, environmental protection, water quality analysis, biological agriculture, scientific research and higher education, etc.
We Can Supply All Kinds Of Water Analysis Instrument To Meet Different Demands. Inquiry us to chooes the best one for you.
Features For M510T-A portable multiparameter water quality meter
* Color High contrast LCD touchscreen, 4.3 inches.
* Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management, Log Management and etc.
* Multi-reading feature allows auto-read, timed-read and continuous-read.
* Automatic/Manual temperature compensation ensures accurate results.
* Auto-hold feature senses and locks the measurement endpoint.
* Data Storage 1000 sets for each parameter (GLP-compliant).
* Data analysis feature helps user review, compare and recalculate results.
* Support for USB communication.
* Auto-power off feature effectively extends the battery service life.
* Reset feature automatically resumes all settings back to factory default options.
* IP65 waterproof.
pH
* 1-8 points calibration with Standard Recognition.
* Selectable pH buffer groups, including USA, NIST, DIN, GB, MERK, JIS.
* User-defined pH buffer or buffer group is supported.
* Automatic electrode diagnosis with pH slope and offset display.
Ion
* 1-6 points calibration.
* Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.
* Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
* Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.
Conductivity
* 1-5 points calibration automatically recognizes the standard solutions.
* Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.
* Temperature compensation type (none, linear, pure water).
Model |
M510T-A |
|
Parameters |
pH/EC/ISE/Temp. (mV/ORP/pX/Resistivity/TDS/Sal.) |
|
pH
|
Range |
-2.000 to 20.000 pH |
Resolution |
0.1, 0.01, 0.001pH |
|
Accuracy |
±0.002 pH |
|
Calibration Points |
Up to 8 |
|
Standard Customization |
Yes |
|
Calibration Reminder |
Yes |
|
Standard Recognition |
USA, NIST, MERK, JIS, GB and DIN buffers |
|
Slope Limit |
Yes |
|
mV/ORP
|
Range |
-2000.00 to 2000.00 mV |
Resolution |
0.1, 0.01 mV |
|
Accuracy |
±0.1 mV or ±0.03% |
|
EH ORP Mode |
Yes |
|
ORP Calibration Points |
1 custom point (relative mV) |
|
pX
|
Range |
-2.000 to 20.000 pX |
Resolution |
0.1, 0.01, 0.001 pX |
|
Accuracy |
±0.002 pX |
|
Calibration Points |
Up to 6 |
|
ISE
|
Range |
1E-9 to 9.999E9 |
Units |
mol/L, mmol/L, g/L, mg/L, μg/L |
|
Resolution |
Up to 4 significant digits |
|
Accuracy |
±0.3% |
|
Calibration Points |
Up to 8 |
|
Conductivity
|
Range |
0.000 μS/cm to 3000 mS/cm |
Resolution |
0.001 μS/cm minimum, various with range selection |
|
Accuracy |
±0.5% FS |
|
Reference Temperature |
5, 10, 15, 18, 20, 25 ºC |
|
Calibration Points |
Up to 5 |
|
Calibration Reminder |
Yes |
|
Standard Recognition |
10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm |
|
Resistivity
|
Range |
5.00 Ω·cm~100.00 MΩ·cm |
Resolution |
0.01 Ω·cm minimum |
|
Accuracy |
±0.5% FS |
|
TDS
|
Range |
0.000mg/L~1000g/L |
Resolution |
0.001mg/L minimum, changed with range |
|
Accuracy |
±0.5% |
|
Salinity
|
Range |
(0.00~8.00)% |
Resolution |
0.01% |
|
Accuracy |
±0.1% |
|
Temperature
|
Range |
-10 to 135 ºC, 14 to 275 ºF |
Unit |
ºC, ºF |
|
Resolution |
0.1 |
|
Relative Accuracy |
±0.1 |
|
Measurement
|
Reading Mode |
Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts |
Reading, Stable, Locked |
|
Temp. Compensation |
ATC, MTC |
|
Data management
|
Data Storage |
1000 Groups |
GLP Features |
Yes |
Inquiry Us For More Details