Lab petroleum equipment flash point tester
Negotiable
Min.Order:1
SYD-261A |
SYD-261D |
SYD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester
Summary
This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.
Main technical features
1. Simulation tracking displays function curves of heating up and test time.
2. Equipped with the English prompt function of mis-operation.
3. Equipped with prompt function of test date,test time and other parameters.
4. Automatically calibrate the effect of atmospheric pressure to test and calculate the corrected value.
5. Differential coefficient detection.Automatically correct the system deviation.
6. Automatically open the lid,detect the flash point and print test data.
7. The test arm rises up and lowers down automatically.
8. Igniting with electric igniting gun,forced air cooling
Main technical specifications
1. Power supply:AC(220±10%)V, 50Hz.
2. Temperature measurement:Range: Room temperature~300℃.
Repeatability: ≤ 2℃
Reproducibility: ≤ 4℃
Accuracy: 0.1℃
3. Heating rate: Procedure A: (5~6)℃/min
Procedure B:(1~1.6)℃/min
Automatic control and manually adjustable.
4. Stirring rate:(1) Procedure A: (90~120)RPM
(2) Procedure B: (250±10)RPM
Automatic control and manually adjustable.
5. Igniting mode: (1) Igniting source: gas(or other civilian fuels,the same below)
(2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
6. Ambient temperature:≤ 40℃
7. Relative humidity:≤ 80%
8. Maximum power consumption: 350W
SYD-261D Fully-automatic Pensky-Martens Closed Cup Flash Point tester
Summary
This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.
Main technical features
1. It adopts LCD screen to display. Full English man-machine dialog interface. It can preset the parameters of expected flash point,sample mark number, atmospheric pressure, test date,etc.It has menu to prompt and input function of guide type.
2. It adopts simulation tracking display the function curve of temperature rising and test time.It has prompt functions of English mis-operation,test date and test time.
3. It is equipped with standard RS-323,485 computer port.The lower computer can save 100 groups of historical data. The test data can be saved for a long time, transmitted and modified if the instrument being connected with computer.
4. It can correct the influence of atmospheric pressure and calculate the correction automatically.
5. Differential detection.Automatically correct the systematic deviation.
6. Automatically open the lid,ignite,detect and print test data.The test arm lifting up and down automatically.
7. It adopts electric ignition to fire light the gas flame.It will light only need to press the button.
8. Humanized design,beautiful and safe. Easy to operate.
Main technical specifications
1. Power supply:AC(220±10%)V, 50Hz
2. Temperature measurement:Range: room temperature~300℃
Repeatability: ≤3℃
Reproducibility:≤6℃
Accuracy:0.1℃
3. Heating rate:Procedure A:(5~6)℃/min
Procedure B:(1~1.6)℃/min
Automatic control and manually adjustable.
4. Stirring rate:(1) Procedure A: (90~120)RPM
(2) Procedure B: (250±10)RPM
Automatic control and manually adjustable.
5. Igniting mode:Electric ignition. Gas flame diameter:3.2mm~4.8mm
6. Working condition:ambient temperature:(10~40)℃
relative humidity:≤80%
7. Maximum power consumption:500W
8. Dimension: 520mm×360mm×310mm
SYD-3536D |
SYD-3536A |
Summary
This instrument is designed and made as per GB/T3536-2008 Petroleum Products - Determination of Flash and Fire Points - Cleveland open cup method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points above 79℃ and below 400℃ except fuel oils.
Main technical features
1. This instrument is a kind of fully-automatic instrument wich can do determination for both flash point and fire point.
2. This instrument adopts technology of single chip microcomputer and LCD screen.Full English man-machine dialog interface. It can preset the parameters of expected flash point,sample mark number, atmospheric pressure, test date,etc.It has menu to prompt and input function of guide type.
3. This instrument adopts desktop structure and advanced design.The man-machine interface make it easy to use.And the test result is accurate.It can be widely used in railway,aviation,electric power, petroleum industry and colleges,scientific research institutes,measurement departments to do determination of flash point and fire point for petroleum products.
Main technical specifications
1. Power supply: AC(220±10%)V, 50Hz
2. Temperature measurement: Range:room temperature~400℃
Repeatability: ≤8℃
Reproducibility:≤17℃
Accuracy:0.1℃
3. Heating rate: Correspond with GB/T3536 and ASTM D92
4. Igniting mode: Electric ignition,
Gas flame diameter: 3.2mm~4.8mm
5. Ambient temperature:(10~40)℃
6. Relative humidity:≤80%
7. Maximum power consumption:500W
8. Dimension:520mm×380mm×310mm Weight:13kg
Summary
This instrument is designed and made as per GB/T3536-2008 Petroleum Products - Determination of Flash and Fire Points - Cleveland open cup method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points above 79℃ and below 400℃ except fuel oils.
Main technical features
1. This instrument adopts LCD screen to display and full English man-machine interface. It can preset expected flash point temperature, sample mark number, barometric pressure and other parameters.It has menu prompt and input guide.
2. It adopts simulation tracking to display the function curve of temperature rising and test time. It has the functions of English mis-operation prompt,test date,test time and other parameters.
3. Automatically calibrate the effect of atmospheric pressure to test and calculate the corrected value.
4. Differential coefficient detection.Automatically correct the system deviation.
5. Automatically open the lid,detect the flash point and print test data.The test arm automatically rise up and lower down.
6. Beautiful design,safe and convenient to operate.
Main technical specifications
1. Power supply:AC220(-10%~+5%)V, 50Hz
2. Temperature measurement:Range:room temperature~400℃
Repeatability:≤8℃
Reproducibility:≤17℃
Accuracy:0.1℃
3. Heating rate:Correspond with GB/T3536 and ASTM D92
4. Ignition mode:Electric ignition. Gas flame diameter is 3.2mm~4.8mm
5. Ambient temperature:(10~40)℃
6. Relative humidity:≤80%
7. Maximum power consumption:400W
8. Dimension:410mm×360mm×310mm
SYD-3536-1 |
SYD-3536 |
Summary
This instrument is designed and made as per GB/T3536-2008 Petroleum Products - Determination of Flash and Fire Points - Cleveland open cup method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points above 79℃ and below 400℃ except fuel oils.
Main technical features
1. It adopts technology of single chip microcomputer and LCD screen. English man-machine interface.The heating device is continuously stepless adjustable.Easy to set parameters.
2. The LCD screen has prompt menu, prompt type input for operation interface. It shows set parameters and real-time display sample temperature and other parameters. Press the record key when flash point appearing. The screen will display and save flash point value.
3. It is newly design,having small structure. Stainless steel working table make it elegant and beautiful. The operator can do determination as long as connecting with coal gas or other civil gas. Easy to use and results are exact.
4. It is equipped with wind-shelter and flame extinguishing cover which are accord with requirements of test.
Accurate heating rate.The instrument can do test automatically.
5. Operator only need to observe the flash point appearing. The cost performance is high.
Main technical specifications
1. Power supply: AC(220±10%)V, 50Hz.
2. Heating device: Electric furnace heating, no naked fire, explosion prevented.The power is adjustable from 0W to 600W. The max heating temperature can reach 400℃.
3. Temperature control: Single chip microcomputer.The heating rate can meet requirements of standards GB/T 3536-2008 and ASTM D92.
4. Temperature display: LCD screen shows temperature parameters. The range is 0℃~400℃, accuracy is 0.1℃.
5. Flash point detecting device: scanning the flash point automatically.
6. Temperature sensor: RTD, PT100
7. Igniting device: (1) Ignition source: coal gas (or civil gas,the same below)
(2) Flame diameter is 3.2mm~4.8mm
8. Ambient temperature: (-10∼50)℃
9. Relative humidity: ≤85%
10.Maximum power consumption: 650W
11.Dimension: 340mm*320mm*450mm (Temperature sensor is included)
Summary
This instrument is designed and made as per standards GB/T3536-2008 Petroleum Products - Determination of Flash and Fire Points - Cleveland open cup method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points above 79℃ and below 400℃ except fuel oils.
Main technical features
1. It adopts special heating furnace to ensure the safety of test. The heating power is continuously adjustable.It can meet requirements of test.
2. The instrument adopts desktop structure.The stainless steel working table and furnace shell make it beautiful and elegant.
3. The instrument is fully self-contained complete.The operator can do determination as long as connecting with coal gas or other civil gas.
4. It equipped with flame extinguishing cover which accord with requirements of test.
Main technical specifications
1. Power supply: AC(220±10%)V, 50Hz.
2. Heating device: Quartz tube furnace heating, no naked fire, explosion prevented.The power is adjustable from 0W to 600W.
3. Test flame applicator: It applies the test flame automatically.
4. Thermometer: (-6~400)℃. It is the same as thermometer ASTM 11C.
5. Igniting device: (1) Ignition source: coal gas(or civil gas,the same below)
(2) Flame diameter is 3.2mm~4.8mm
6. Ambient temperature: (-10∼50)℃
7. Relative humidity: ≤85%
8. Maximum power consumption: 650W
9. Dimension: 350mm×290mm×350mm (thermometer is not included)
SYD-261-1 |
SYD-261 |
Summary
This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.
Main technical features
1. Single chip microcomputer control technique.LCD screen displays.English man-machine interaction interface.The heating power is continuously step-less adjustable.The rate of heating up is exact.Easy setting for parameters.
2. The LCD screen has prompting menu,prompting input operation interface.It shows the setted parameters,real-time temperatures and other test parameters.Press the “record”button when the flash point appears.The screen will show and reserve the flash point.
3. The structure is newly design and small.Stainless steel table-board looks clean and beautiful.It can be used as long as equipped with gas or other civilian fuels.It is easy to use and test results exact.
Main technical specifications
1. Power supply:AC( 220±10% )V, 50Hz.
2. Heating device:(1) The furnace is silicon carbide material. Power is 600W.
(2) The heating power is adjustable from 0 W to 600W.
3. Heating rate:Procedure A: (5~6)℃/min
Procedure B :(1~1.6)℃/min
Automatically controlled
4. Stirring device:(1)Stirring motor: BYGH101 stepping motor
(2) Driving mode: flexible shaft
(3) Shaft size: 8mm×40mm
5. Stirring rate:(1) Procedure A: (90~120)RPM
(2) Procedure B: (250±10)RPM
6. Igniting device: (1) Igniting source: gas(or other civilian fuels,the same below)
(2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
7. Temperature testing probe:PT100
8. Ambient temperature:≤ 35℃
9. Relative humidity:≤ 85%
10.Maximum power consumption:650W
Summary
This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.
Main technical features
1. This instrument is designed as per GB/T261 and ASTM D93.
2. The heating power is continuously and steplessly adjustable. The power is shown visually by voltmeter.The temperature control mode is advanced and reasonable.
3. The structure is designed small and exquisite.The stainless-steel table board is beautiful and easy to clean.
4. Operation is easy.Test results are precise.It has been chosen as the instrument to test the closed cup flash point by many metering and detecting institutes.
Main technical specifications
1. Power supply:AC (220±10%)V, 50Hz.
2. Heating device::The heating power is continuously adjustable from 0 W to 600W.
3. Heating rate::(1~12)℃/min;Controllable and adjustable.
4. Stirring rate:(1) Procedure A: (90~120)RPM
(2) Procedure B: (250±10)RPM
5. Standard oil cup:(1) Inner diameter: 50.7mm~50.8mm.
(2) Depth: 55.7mm~56.0mm
(3) The scribed line depth of capacity of testing oil: 33.9mm~34.3mm.
(4) Capacity of testing oil:about 70ml
6. Igniting device:(1) Igniting source: gas(or other civilian fuels,the same below)
(2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
7. Thermometers:Mercury-in-glass thermometer.Specifications are as below:
(1)Scale -5℃~110℃, division 0.5℃.
(2)Scale 20℃~150℃, division 1℃.
(3)Scale 90℃~370℃,division 2℃.
8. Ambient temperature:≤ 35℃
9. Relative humidity:≤ 85%
10.Maximum power consumption:650W
Pre-sale service
Contract execution
After-sale service
1. How can I choose the suitable one?
Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
2. Does your price is competitive?
Dear customer, we make sure to offer you the best quality with competitive price.
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union…
4. When I receive it after pay?
Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.
5. How to deliver?
Dear customer, we can send by Express, by Sea and by Air.
6. Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.
7. What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.
8. What should I do if some parts broken?
Dear customer, please do not worry, we have 12months warranty except wear parts. You can also buy parts from us after 12months.