Kingyear VV32 YJV32 4C 70mm2 4 Core 50mm2 5x16mm XLPE Insulated Armored Electrical Power Cable
Negotiable
Min.Order:1
Henan Kingyear Aluminum Industrial Co., Ltd.
XLPE Insulated 6mm 25mm2 50mm2 500mm2 600mm2 33kv Single Core Power Cable
Armoured 1x240 1x500mm2 1x630mm2 240mm XLPE Insulated HV Power cable
medium voltage 11KV up to 35KV XLPE insulated and PVC sheathed armored MV power cable
Kingyear 630mm2 800mm2 Underground Aluminum Copper Xlpe Insulated High Voltage Power Cable
The detail technical data of VV32 YJV32 4C 70mm2 4 Core 50mm2 5x16mm XLPE Insulated Armored Electrical Power Cable as below for reference,any customized is available. | ||||||||||||||||||
Rated Voltage, No. of Core and Range of Sectional Area | ||||||||||||||||||
Rated voltage (kv) Sectional area (mm2) No. of core | 1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 | |||||||||
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | - | 26/35 | ||||||||||
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | ||||||||||
2 Core | 1.5-185 | 25-185 | ||||||||||||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | ||||||||||
4 Core | 2.5-400 | 25-400 | ||||||||||||||||
5 Core | 2.5-400 | 25-400 |
The detail technical data of VV32 YJV32 4C 70mm2 4 Core 50mm2 5x16mm XLPE Insulated Armored Electrical Power Cable as below for reference,any customized is available. | ||||||||||||||||||
Rated Voltage, No. of Core and Range of Sectional Area | ||||||||||||||||||
Rated voltage (kv) Sectional area (mm2) No. of core | 1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 | |||||||||
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | - | 26/35 | ||||||||||
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | ||||||||||
2 Core | 1.5-185 | 25-185 | ||||||||||||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | ||||||||||
4 Core | 2.5-400 | 25-400 | ||||||||||||||||
5 Core | 2.5-400 | 25-400 |
DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values. | ||||||||||
Nominal section area (mm2) | Copper core | Aluminum core | Nominal section area (mm2) | Copper core | Aluminum core | |||||
1.5 | 12.1 | 18.1 | 95 | 0.193 | 0.32 | |||||
2.5 | 7.41 | 12.1 | 120 | 0.153 | 0.253 | |||||
4 | 4.61 | 7.41 | 150 | 0.124 | 0.206 | |||||
6 | 3.08 | 4.61 | 185 | 0.099 | 0.164 | |||||
10 | 1.83 | 3.08 | 240 | 0.0754 | 0.125 | |||||
16 | 1.15 | 1.91 | 300 | 0.0601 | 0.1 | |||||
25 | 0.727 | 1.2 | 400 | 0.047 | 0.778 | |||||
35 | 0.524 | 0.868 | 500 | 0.0366 | 0.0605 | |||||
50 | 0.387 | 0.641 | 630 | 0.0283 | 0.0469 | |||||
70 | 0.268 | 0.443 | 800 | 0.0221 | 0.0367 |