Aluminum Conductor XLPE Insulation Aerial Overhead Insulated Cable
Negotiable
Min.Order:1
Henan Kingyear Aluminum Industrial Co., Ltd.
Price XLPE Insulated 1AWG Quadruplex Service Drop Aluminum Aerial Insulated Cables
Aerial Bundle Cable/Service Drop Wire Aluminum Bare Conductor ABC Cable
0.6/1kv abc kabel 120mm2 4core electric cable 3x50mm2 2x16mm2 3*120mm2 2x25mm2 cable xlpe aluminio
Latest 0.6/1kv 2 Core 3 Core 4 Core Overhead Insulation ABC Cable
Low Voltage 0.6/1kv Pvc Xlpe Insulated Aluminum Conductor ABC Cable
Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | ||||||||||||||
Size & No.of wires | Insulation Thick (mm) | Nominal Dia.(mm) | Size & No.of wires | Rated Strength (kg) | XLPE (kg/km) | Al. | ( A ) | |||||||||||
Bare (mm) | OD (mm) | |||||||||||||||||
AAC | ||||||||||||||||||
Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 | |||||||||
Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 | |||||||||
Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 | |||||||||
Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 | |||||||||
Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 | |||||||||
Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 | |||||||||
Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 | |||||||||
Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | - | 56.5 | 233.6 | 158 | |||||||||
Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
AAAC | ||||||||||||||||||
Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 | |||||||||
VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 | |||||||||
Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 | |||||||||
Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 | |||||||||
Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 | |||||||||
Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
ACSR | ||||||||||||||||||
Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 | |||||||||
Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 | |||||||||
Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 | |||||||||
Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 | |||||||||
Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 | |||||||||
Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 | |||||||||
Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 | |||||||||
Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 | |||||||||
Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Duplex Service Drop ABC Cable Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting.For service at 600 volts or lower at a conductor temperature of 75°C maximum. | ||||||||||||||||||
Triplex Service Drop ABC Cable Application: To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation. | ||||||||||||||||||
Quadruplex Service Drop. ABC Cable Applications:Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors. |