Latvia turkey uruguay electrical cable and wire aaac 25mm2 bare all aluminum alloy conductor price
Negotiable
Min.Order:1
Henan Kingyear Aluminum Industrial Co., Ltd.
AAC | ||||||||||||||||||
Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 | |||||||||
Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 | |||||||||
Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 | |||||||||
Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 | |||||||||
Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 | |||||||||
Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 | |||||||||
Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 | |||||||||
Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | - | 56.5 | 233.6 | 158 | |||||||||
Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
AAAC | ||||||||||||||||||
Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 | |||||||||
VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 | |||||||||
Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 | |||||||||
Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 | |||||||||
Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 | |||||||||
Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
ACSR | ||||||||||||||||||
Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 | |||||||||
Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 | |||||||||
Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 | |||||||||
Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 | |||||||||
Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 | |||||||||
Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 | |||||||||
Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 | |||||||||
Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 | |||||||||
Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Applications of aaac 240mm2 | To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum. | |||||||||||||||||
Applications of conductor aaac 240mm2 | To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation. | |||||||||||||||||
Applications of conductor aaac 240mm2 | Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors |