aaac mulberry aaac concentric cable 35mm2 aluminum alloy electrical wire cable
aaac mulberry aaac concentric cable 35mm2 aluminum alloy electrical wire cable
aaac mulberry aaac concentric cable 35mm2 aluminum alloy electrical wire cable
aaac mulberry aaac concentric cable 35mm2 aluminum alloy electrical wire cable
aaac mulberry aaac concentric cable 35mm2 aluminum alloy electrical wire cable

aaac mulberry aaac concentric cable 35mm2 aluminum alloy electrical wire cable

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Henan Kingyear Aluminum Industrial Co., Ltd.

Business Type: Distributor/Wholesaler
Main Products: , , ,

Product Details


aaac mulberry aaac concentric cable 35mm2 aluminum alloy electrical wire cable
Products Description
Applications:
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics. Aluminum-alloy 6201-T81 gives AAAC higher resistance to corrosion than ACSR.
Advantage:
1. AAAC exhibits excellent corrosion resistance specially in sea coast areas and in polluted industrial areas due to absence of steel core.
2. Since AAAC is homogeneous (with all strands of Aluminium Alloy) with no steel component the resistance of AAAC is lower as compared to ACSR.
3. Higher Ampacity: AAAC can carry atleast 15-20% extra current as compared to ACSR of equal size.
4. Experience in foreign countries shows that All Aluminium Alloy Conductors are in service for over 60 years, which is about double the life of ACSR Conductors.
Standard
ASTM B399, IEC61089, BS 3242, BS EN 50182, DIN 48201, AS 1531

The technical data of AAAC All Aluminum Alloy Bare Conductor Cable as below for reference,any customized is available.

Product parameters
ASTM B 399/B 399M
Code Name
Total Area
1350 Grade Equivalent
No./Dia.
of Wire
Approx. Overall Diameter
Approx. Weight
Calculated Breaking
Load
Max.DC Resistance at 20° C
AWG or MCM
mm2
(Approx.)
AWG or MCM
No. / mm
mm
kg/km
kN
Ohm/km
Akron
30.6
15.5
6
7/1.68
5.04
43
4.9
2.1588
Alton
48.7
24.7
4
7/2.12
6.36
68
7.8
1.3557
Ames
77.5
39.2
2
7/2.67
8.01
108
12.4
0.8547
Azusa
123.3
62.4
1
7/3.37
10.11
171
18.9
0.5365
Anaheim
155.4
78.6
2/0
7/3.78
11.34
216
23.8
0.4264
Amherst
195.7
99.3
3/0
7/4.25
12.75
272
30
0.3373
Alliance
246.9
125.1
4/0
7/4.77
14.31
343
37.8
0.2678
Butte
312.8
158.6
266.8
19/3.26
16.3
435
46.5
0.2112
Canton
394.5
199.9
336.4
19/3.66
18.3
548
58.6
0.1676
Cairo
465.4
236.4
397.5
19/3.98
19.9
649
69.3
0.1417
Darien
559.5
283.6
477
19/4.36
21.8
778
83.1
0.1181
Elgin
652.6
331
556.5
19/4.71
23.55
908
97
0.1012
Flint
740.8
374.5
636
19/3.59
25.13
1028
107.4
0.0894
Greeley
927.2
469.6
795
19/4.02
28.14
1289
134.6
0.0713
IEC 61089
Code Name
Nominal
No./Nominal
diameter of
wires
Approximate
Overall
Diameter
Approximate
Weight
Nominal
Breaking
Load
Nominal DC
Resistance
at 20°C
mm2
No./mm
mm
kg/km
KN
ohm/km
10
10
7/1.35
4.05
27.4
2
2.8633
16
16
7/1.71
5.13
43.8
3
1.7896
25
25
7/2.13
6.39
68.4
4.5
1.1453
40
40
7/2.70
8.1
109.4
6.8
0.7158
63
63
7/3.39
10.17
172.3
10.4
0.4545
100
100
19/2.59
12.95
274.8
17
0.2877
125
125
19/2.89
14.45
343.6
21.3
0.2302
160
160
19/3.27
16.35
439.8
26.4
0.1798
200
200
19/3.66
18.3
549.7
32
0.1439
250
250
19/4.09
20.45
687.1
40
0.1151
315
315
37/3.29
23.03
867.9
52
0.0916
400
400
37/3.71
25.97
1102
64
0.0721
450
450
37/3.94
27.58
1239.8
72
0.0641
500
500
37/4.15
29.05
1377.6
80
0.0577
560
560
37/4.39
30.73
1542.9
89.6
0.0515
630
630
61/3.63
32.67
1738.3
100.8
0.0458
710
710
61/3.85
34.65
1959.1
113.6
0.0407
800
800
61/4.09
36.81
2207.4
128
0.0361
900
900
61/4.33
38.97
2483.3
144
0.0321
1000
1000
61/4.57
41.13
2759.2
160
0.0289
1120
1120
91/3.96
43.56
3093.5
179.2
0.0258
1250
1250
91/4.18
45.98
3452.6
200
0.0231
1400
1400
91/4.43
48.73
3866.9
224
0.0207
1500
1500
91/4.58
50.38
4143.1
240
0.0193
DIN 48201 Part 5
Nominal Area
Calculated Area
Stranding and Wire Diameter
Overall
Diameter
Weight
Calculated Breaking Load
Max.DC Resistance at 20° C
mm2
mm2
No.xmm
mm
kg/km
daN
Ω/Km
16
15.89
7/1.70
5.1
44
290
1.8018
25
24.25
7/2.10
6.3
67
425
1.1808
35
34.36
7/2.50
7.5
94
585
0.8332
50
49.48
7/3.00
9
135
810
0.5786
55
48.35
19/1.80
9
133
860
0.595
70
65.81
19/2.10
10.5
181
1150
0.4371
95
93.27
19/2.50
12.5
256
1595
0.3084
120
116.99
19/2.80
14
322
1910
0.2459
150
147.11
37/2.25
15.8
406
2570
0.196
185
181.62
37/2.50
17.5
501
3105
0.1587
240
242.54
61/2.25
20.3
670
4015
0.1191
300
299.43
61/2.50
22.5
827
4850
0.0965
400
400.14
61/2.89
26
1105
6190
0.0722
500
499.83
61/3.23
29.1
1381
7600
0.0578
625
626.2
91/2.96
32.6
1733
9690
0.04625
800
802.1
91/3.35
36.8
2219
12055
0.03611
1000
999.71
91/3.74
41.1
2766
14845
0.02897
COMPANY STRENGTH

COMPANY PROFILE

HENAN KINGYEAR GROUP was founded in 2006,located in the Gongyi industry area of Henan Province.Occupies more than 1200,000 square meters,more than 800 employees.Our company consists of 3 main subsidiaries,Business specialized in development,manufacture and distribution of aluminum and cable products.Mainly including aluminum plate,aluminum coil,bare aluminum conductor,aerial bundled cable,Low voltage and medium voltage power cable,Electrical wire,control cable,etc... CLICK MORE
PLANT AND OFFICE SHOWN:
3 workshops of AAC/ACSR/AAAC Bare Conductor/Power Cable, 1 office building of international trade.
TESTING MACHINE SHOWN: aac/aaac/acsr stranded bare cable testing :
CERTIFICATE SHOWN:
ISO,CE,CCC,ROHS,UL,VDE
CUSTOMER
After more than 20 years of development, our customers have spread to more than 40 countries and regions around the world, And more than 50% are old customers.The power cable,control cable,ABC cable,bare conductor(AAC/AAAC/ACSR) are more favorited by them.We are proud of our good quality---KINGYEAR CABLE.
PACKAGE
PACKAGING FLOW of aac/aaac/acsr stranded bare conductor and abc power cable as below, customized is accepted.
Some of our products packaging records shown:
They are about aaac mulberry aaac concentric cable 35mm2 aluminum alloy electrical wire cable price.
FAQ
Q:I didn't find the aaac mulberry aaac concentric cable 35mm2 aluminum alloy electrical wire cable which I need in this page?
A:If you didn't find the species of cables you need, please contact us directly, we will reply you quickly.

Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.

Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.

Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us,we will send you the free sample, but the freight charge should be paid.

Q:How to ensure quality ?
A:For any quality problems, we will arrange the technical personnel to solve or return the goods as soon as possible, and bear the corresponding customer losses.

Q:What if the cable which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include cable, color, material, processing requirement etc.

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electric Cable
Categories
Hi~