(Aluminum Alloy Strand Conductor) AASC Conductor 120mm2 185mm2 240mm2 BS EN 50183
(Aluminum Alloy Strand Conductor) AASC Conductor 120mm2 185mm2 240mm2 BS EN 50183
(Aluminum Alloy Strand Conductor) AASC Conductor 120mm2 185mm2 240mm2 BS EN 50183
(Aluminum Alloy Strand Conductor) AASC Conductor 120mm2 185mm2 240mm2 BS EN 50183
(Aluminum Alloy Strand Conductor) AASC Conductor 120mm2 185mm2 240mm2 BS EN 50183

(Aluminum Alloy Strand Conductor) AASC Conductor 120mm2 185mm2 240mm2 BS EN 50183

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Henan Kingyear Aluminum Industrial Co., Ltd.

Business Type: Distributor/Wholesaler
Main Products: , , ,

Product Details

(Aluminum Alloy Strand Conductor) AASC Conductor 120mm2 185mm2 240mm2 BS EN 50183
PRODUCT DESCRIPTION
Application:
* Used as bare overhead conductor for primary and secondary distribution.
* Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag
characteristics.
* Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.

Features:
* Large span and long crossing is possible. Tensile strength is much higher than All Aluminum Conductor.
* Lower tower is possible. Light in weight and better sag characteristic approx 1.3-1.4 times better than AAC.
* Better Ampacity and Overload safely as well as its corrosion resistance.
* Excellent and comprehensive performance could save your cost and time in tower construction, installation and maintenance.
Standard:  BS EN50183 ,IEC 61089, ASTM B399, BS 3242, DIN 48204, GB/T1179-2008 Construction:
* Concentric-lay stranded.
* The AAAC Conductor is manufactured from a heat-treated, magnesium-silicide high-strength 6201-T81 aluminum alloy.
* Popular Aluminum alloy Strands 7, 19, 37, 61 or more wires.

ASTM B399


Code Name
Area
Size & Stranding of ACSR with Equal Diamete
No. & Diameter of wires
Overall Diameter

Weight
Nominal Breaking Load
Nominal
Actual
MCM
mm2
AWG or MCM
Al/Steel
mm
mm
kg/km
kN
Akron
30.58
15.48
6
6/1
7/1.68
5.04
42.7
4.92
Alton
48.69
24.71
4
6/1
7/2.12
6.35
68.0
7.84
Ames
77.47
39.22
2
6/1
7/2.67
8.02
108
12.45
Azusa
123.3
62.38
1/0
6/1
7/3.37
10.11
172
18.97
Anaheim
155.4
78.65
2/0
6/1
7/3.78
11.35
217
23.93
Amherst
195.7
99.22
3/0
6/1
7/4.25
12.75
273
30.18
Alliance
246.9
125.1
4/0
6/1
7/4.77
14.31
345
38.05
Butte
312.8
158.6
266.8
26/7
19/3.26
16.30
437
48.76
Canton
394.5
199.9
336.4
26/7
19/3.66
18.30
551
58.91
Cairo
465.4
235.8
397.5
26/7
19/3.98
19.88
650
69.48
Darien
559.5
283.5
477.0
26/7
19/4.36
21.79
781
83.52
Elgin
652.4
330.6
556.5
26/7
19/4.71
23.54
911
97.42
Flint
740.8
375.3
636.0
26/7
37/3.59
25.16
1035
108.21
Greely
927.2
469.8
795.0
26/7
37/4.02
28.14
1295
135.47
BS EN50183
Code Name
Calculated
Cross Section
No..Dia.of Wires
Overall Diameter
Weight
Rated Strength

mm²
No./mm
mm
kg/km
kN
Box
18.8
7/1.85
5.55
51.4
5.55
Acacia
23.8
7/2.08
6.24
64.9
7.02
Almond
30.1
7/2.34
7.02
82.2
8.88
Cedar
35.5
7/2.54
7.62
96.8
10.46
Deodar
42.2
7/2.77
8.31
115.2
12.44
Fir
47.8
7/2.95
8.85
130.6
14.11
Hazel
59.9
7/3.30
9.90
163.4
17.66
Pine
71.6
7/3.61
10.8
195.6
21.14
Holly
84.1
7/3.91
11.7
229.5
24.79
Willow
89.7
7/4.04
12.1
245,0
26.47
Oak
118.9
7/4.65
14.0
324.5
35.07
Mulberry
150.9
19/3.18
15.9
414.3
44.52
Ash
180.7
19/3.48
17.4
496.1
53.31
Elm
211.0
19/3.76
18.8
579.2
62.24
Poplar
239.4
37/2.87
20.1
659.4
70.61
Sycamore
303.2
37/3.23
22.6
835.2
89.40
Upas
362.1
37/3.53
24.7
997.5
106.82
Yew
479.0
37/4.06
28.4
1319.6
141.31
Totara
498.1
37/4.14
29.0
1372.1
146.93
Rubus
586.9
61/3.50
31.5
1622.0
173.13
Sorbus
659.4
61/3.71
33.4
1822.5
194.53
Araucaria
821.1
61/4.14
37.3
2269.4
242.24
Redwood
996.2
61/4.56
41.0
2753.2
293.88
DIN 48201
Code number
Calculated area
Number of wires
Diameter of wire
Overall diameter of conductor
Linear mass
Rated tensile strength
Max. DC resistance at 20℃
mm2
mm2

mm
mm
kg/km
daN
Ω/km
16
15.89
7
1.70
5.1
43
444
2.0910
25
24.25
7
2.10
6.3
66
677
1.3703
35
34.36
7
2.50
7.5
94
960
0.9669
50
49.48
7
3.00
9.0
135
1382
0.6714
50
48.35
19
1.80
9.0
133
1350
0.6905
70
65.81
19
2.10
10.5
181
1838
0.5073
95
93.27
19
2.50
12.5
256
2605
0.3579
120
116.99
19
2.80
14.0
322
3268
0.2854
150
147.11
37
2.25
15.8
406
4109
0.2274
185
181.62
37
2.50
17.5
500
5073
0.1842
240
242.54
61
2.25
20.3
670
6774
0.1383
300
299.43
61
2.50
22.5
827
8363
0.1120
400
400.14
61
2.89
26.0
1104
11176
0.0838
500
499.63
61
3.23
29.1
1379
13960
0.06709
625
626.20
91
2.96
32.6
1732
17490
0.0540
800
802.09
91
3.35
36.9
2218
22402
0.0418
1000
999.71
91
3.74
41.1
2767
27922
0.0335
PACKAGING&TRANSPORT
PACKAGING FLOW of AASC Conductor 120mm2 185mm2 240mm2
Different cable drum of AASC Conductor 120mm2 185mm2 240mm2
RELATED PRODUCTS
Similar Products(Different structure; Different size)
AAC(All Aluminum Conductor)
AAAC(All Aluminum Alloy Conductor)
ACSR(Aluminun Conductor Steel Reinforced)
ACSR/AW ACSR/AS ACSR/AC
AACSR TACSR TACSR/AW
ACAR(Aluminum Conductor Aluminum Alloy Reinforced)
ACCC(Aluminum Composite Core Conductor)
Galvanized Steel Wire /Strand(GSW,SC/GZ)
Aluminum Clad Steel Wire(Alumoweld,ACS,SC/AC)
Aluminum Rod
COMPANY STRENGTH


HENAN KINGYEAR GROUP was founded in 2006,located in the Gongyi industry area of Henan Province.Occupies more than 1200,000 square meters,more than 800 employees.Our company consists of 3 main subsidiaries,Business specialized in development,manufacture and distribution of aluminum and cable products.Mainly including aluminum plate,aluminum coil,bare aluminum conductor,aerial bundled cable,Low voltage and medium voltage power cable,Electrical wire,control cable,etc... CLICK MORE
PLANT AND OFFICE SHOWN:
3 workshops of AASC Conductor 120mm2 185mm2 240mm2
TESTING MACHINE SHOWN: AASC Conductor 120mm2 185mm2 240mm2
CERTIFICATE SHOWN:
ISO,CE,CCC,VDE of AASC Conductor 120mm2 185mm2 240mm2
CUSTOMER
After more than 20 years of development, our customers have spread to more than 40 countries and regions around the world, And more than 50% are old customers.The power cable,control cable,ABC cable,bare conductor(AAC/AAAC/ACSR) are more favorited by them.We are proud of our good quality---KINGYEAR CABLE.
FAQ
Q:I didn't find the cable which I need in this page?
A:If you didn't find the species of cables you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us,we will send you the free sample, but the freight charge should be paid.
Q:How to ensure quality ?
A:For any quality problems, we will arrange the technical personnel to solve or return the goods as soon as possible, and bear the corresponding customer losses.
Q:What if the cable which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include cable, color, material, processing requirement etc.
WHY CHOOSE US

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electric Cable
Categories
Hi~