IEC Standard Overhead Line AAC Aluminium Power Cable AAC Bare Conductor
Products Description
Applications:
Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized.
The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas.Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are
available for this purpose.
Advantage:
1. High Current Carrying Capacity.
2. Excellent resistance to corrosion.
3. Ideal for use in coastal area.
4. Suitable for low & medium voltage lines in urban area.
Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized.
The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas.Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are
available for this purpose.
Advantage:
1. High Current Carrying Capacity.
2. Excellent resistance to corrosion.
3. Ideal for use in coastal area.
4. Suitable for low & medium voltage lines in urban area.
Standard
ASTM B 231, BS 215, IEC 61089, DIN 48201, BS EN 50182
The technical data of AAC All Aluminum Bare Conductor Cable as below for reference,any customized is available.
Product parameters
IEC 61089 | ||||||||||||
Code Name | Nominal | No./Nominal diameter of wires | Approximate Overall Diameter | Approximate Weight | Nominal Breaking Load | Nominal DC Resistance at 20°C | ||||||
mm2 | No./mm | mm | kg/km | KN | ohm/km | |||||||
10 | 10 | 7/1.35 | 4.05 | 27.4 | 2 | 2.8633 | ||||||
16 | 16 | 7/1.71 | 5.13 | 43.8 | 3 | 1.7896 | ||||||
25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 | ||||||
40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 | ||||||
63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.4 | 0.4545 | ||||||
100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 | ||||||
125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.3 | 0.2302 | ||||||
160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 | ||||||
200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 | ||||||
250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 | ||||||
315 | 315 | 37/3.29 | 23.03 | 867.9 | 52 | 0.0916 | ||||||
400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 | ||||||
450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 | ||||||
500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 | ||||||
560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 | ||||||
630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 | ||||||
710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 | ||||||
800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 | ||||||
900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 | ||||||
1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 | ||||||
1120 | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 | ||||||
1250 | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 | ||||||
1400 | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 | ||||||
1500 | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 |
ASTM B231 | ||||||||||||||
Code Name | Total Area | Stranding and Wire Diameter | Overall Diameter | Liner Mass | Nominal Breaking Load | Max. D.C. Resistance at 20ºC | ||||||||
AWG or MCM | mm² | mm | mm | kg/km | daN | Ω/km | ||||||||
Peachbell | 6 | 13.29 | 7/1.554 | 4.67 | 37 | 249 | 2.1692 | |||||||
Rose | 4 | 21.16 | 7/1.961 | 5.89 | 58 | 396 | 1.3624 | |||||||
Iris | 2 | 33.61 | 7/2.474 | 7.42 | 93 | 597 | 0.8577 | |||||||
Pansy | 1 | 42.39 | 7/2.776 | 8.33 | 117 | 732 | 0.6801 | |||||||
Pappy | 1/0 | 53.48 | 7/3.119 | 9.36 | 147 | 873 | 0.539 | |||||||
Aster | 2/0 | 67.42 | 7/3.503 | 10.51 | 186 | 1100 | 0.4276 | |||||||
Phlox | 3/0 | 85.03 | 7/3.932 | 11.8 | 234 | 1347 | 0.339 | |||||||
Oxlip | 4/0 | 107.23 | 7/4.417 | 13.26 | 296 | 1698 | 0.2688 | |||||||
Valerian | 250 | 126.71 | 19/2.913 | 14.57 | 349 | 2062 | 0.2275 | |||||||
Sneezewort | 250 | 126.71 | 7/4.80 | 14.4 | 349 | 2007 | 0.2275 | |||||||
Laurei | 266.8 | 135.16 | 19/3.01 | 15.05 | 373 | 2200 | 0.2133 | |||||||
Dalsy | 266.8 | 135.16 | 7/4.96 | 14.9 | 373 | 2141 | 0.2133 | |||||||
Peany | 300 | 152 | 19/3.193 | 15.97 | 419 | 2403 | 0.1896 | |||||||
Tulip | 336.4 | 170.45 | 19/3.381 | 16.01 | 470 | 2695 | 0.1691 | |||||||
Daftodil | 350 | 177.35 | 19/3.447 | 17.24 | 489 | 2804 | 0.1625 | |||||||
Canna | 397.5 | 201.42 | 19/3.673 | 18.36 | 555 | 3184 | 0.1431 | |||||||
Goldentufl | 450 | 228 | 19/3.909 | 19.55 | 629 | 3499 | 0.1264 | |||||||
Syringa | 477 | 241.68 | 37/2.882 | 20.19 | 666 | 3849 | 0.1193 | |||||||
Cosmos | 477 | 241.68 | 19/4.023 | 20.12 | 666 | 3708 | 0.1193 | |||||||
Hyacinth | 500 | 253.35 | 37/2.951 | 20.65 | 698 | 4035 | 0.1138 | |||||||
Zinnia | 500 | 253.35 | 19/4.12 | 20.6 | 698 | 3888 | 0.1138 | |||||||
Dahlia | 556.5 | 282 | 19/4.346 | 21.73 | 777 | 4327 | 0.1022 | |||||||
Mistletoe | 556.5 | 282 | 37/3.114 | 21.79 | 777 | 4362 | 0.1022 | |||||||
Meadowsweet | 600 | 304 | 37/3.233 | 22.63 | 838 | 4703 | 0.0948 | |||||||
Orchid | 636 | 322.25 | 37/3.33 | 23.31 | 888 | 4985 | 0.0894 | |||||||
Heuchera | 650 | 329.35 | 37/3.366 | 23.56 | 908 | 5095 | 0.0875 | |||||||
Flag | 700 | 354.71 | 61/2.72 | 24.48 | 978 | 5146 | 0.0813 |
BS 215 Part 1 | ||||||||||||||
Code name | Nominal | No./Nominal diameter of wires | Sectional Area | Overall | Weight | Calculated Breaking Load | Max.D.C. Resistance at 20ºC | |||||||
mm² | No./mm | mm² | mm | kg/km | daN | Ω/Km | ||||||||
Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 | |||||||
Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 | |||||||
Gnat | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 | |||||||
Weevil | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 | |||||||
Mosquito | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 | |||||||
Ladybird | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 | |||||||
Ant | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 | |||||||
Fly | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 | |||||||
Bluebottle | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 | |||||||
Earwig | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 | |||||||
Grasshopper | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 | |||||||
Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 | |||||||
Wasp | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 | |||||||
Beetle | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 | |||||||
Bee | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 | |||||||
Cricket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 | |||||||
Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 | |||||||
Caterpillar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 | |||||||
Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 | |||||||
Spider | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 | |||||||
Cockroach | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 | |||||||
Butterfly | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 | |||||||
Moth | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 | |||||||
Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 | |||||||
Locust | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 | |||||||
Centipede | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 | |||||||
Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 | |||||||
Scorpion | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 | |||||||
Cicada | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 | |||||||
Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
DIN 48201 Part 5 | ||||||||||||
Nominal Area | Calculated Area | Stranding and Wire Diameter | Overall Diameter | Weight | Calculated Breaking Load | Max.DC Resistance at 20° C | ||||||
mm2 | mm2 | No.xmm | mm | kg/km | daN | Ω/Km | ||||||
16 | 15.89 | 7/1.70 | 5.1 | 44 | 290 | 1.8018 | ||||||
25 | 24.25 | 7/2.10 | 6.3 | 67 | 425 | 1.1808 | ||||||
35 | 34.36 | 7/2.50 | 7.5 | 94 | 585 | 0.8332 | ||||||
50 | 49.48 | 7/3.00 | 9 | 135 | 810 | 0.5786 | ||||||
55 | 48.35 | 19/1.80 | 9 | 133 | 860 | 0.595 | ||||||
70 | 65.81 | 19/2.10 | 10.5 | 181 | 1150 | 0.4371 | ||||||
95 | 93.27 | 19/2.50 | 12.5 | 256 | 1595 | 0.3084 | ||||||
120 | 116.99 | 19/2.80 | 14 | 322 | 1910 | 0.2459 | ||||||
150 | 147.11 | 37/2.25 | 15.8 | 406 | 2570 | 0.196 | ||||||
185 | 181.62 | 37/2.50 | 17.5 | 501 | 3105 | 0.1587 | ||||||
240 | 242.54 | 61/2.25 | 20.3 | 670 | 4015 | 0.1191 | ||||||
300 | 299.43 | 61/2.50 | 22.5 | 827 | 4850 | 0.0965 | ||||||
400 | 400.14 | 61/2.89 | 26 | 1105 | 6190 | 0.0722 | ||||||
500 | 499.83 | 61/3.23 | 29.1 | 1381 | 7600 | 0.0578 | ||||||
625 | 626.2 | 91/2.96 | 32.6 | 1733 | 9690 | 0.04625 | ||||||
800 | 802.1 | 91/3.35 | 36.8 | 2219 | 12055 | 0.03611 | ||||||
1000 | 999.71 | 91/3.74 | 41.1 | 2766 | 14845 | 0.02897 |
Company Profile
Exhibition
Certificate
Transport
FAQ
Q:I didn't find the IEC Standard Overhead Line AAC Aluminium Power Cable AAC Bare Conductor which I need in this page?
A:If you didn't find the species of cables you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:How to ensure quality ?
A:For any quality problems, we will arrange the technical personnel to solve or return the goods as soon as possible, and bear the corresponding customer losses.
Q:What if the cable which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include cable, color, material, processing requirement etc.