High Quality Knx Bus Control Cable 2x2x0.8mm Bare Copper Pe Insulation Pvc Jacket 100m KNX Cable
Negotiable
Min.Order:1
Product name: | KNX/EIB European bus cable | |
Model specification: | BUS EIB 2*2*0.8|J-Y(st)Y 2*2*0.8|YCYM 2*2*0.8 | |
Product standard: | KNX/EIB DIN VDE 0815 | |
Conductor: | 0.8mm BC, solid, oxygen-free copper (99.99% grade), low resistance, to ensure that the cable voltage is reduced; | |
Insulation: | PVC material, core wire color: red, black, white, yellow; | |
Stranded: | 4-core insulated stranded, wrapped with moisture-proof plastic tape; | |
Shielding: | drain wire (0.4mm) BC bare copper wire + aluminum foil 100% shielding; | |
Sheath: | environmentally friendly light green polyvinyl chloride material, the outer diameter of the finished product does not exceed 6.7mm, and the color refers to the RAL 6017 color spectrum; | |
Packing: | 100m/roll | |
product description: Electrical performance (at 20℃), conductor resistance, maximum 73.2Ω/km; Insulation resistance, minimum 100MΩ·km; Capacitance, line to line, normal value 100nF/km at 800Hz; Inductance, the normal value is 0.65mH/km at 800Hz; Capacitive coupling, the maximum value is 300k pF/100m at 800Hz; Characteristic impedance, the normal value is 85Ω at 100kHz; The normal value is 75Ω attenuation at 1MHz, and the normal value is 3.5dB/km at 10kHz; The normal value is 8dB/km at 100k Hz. Working voltage (not used by power system), peak value, 300V; Test voltage, between conductors, 1 000V; Conductor pair shielding, 1 000V; water immersion test, 5min, 4 000V. | ||
Mechanical and physical properties: Minimum bending radius (fixed installation), 10 times the diameter of the finished product; The maximum allowable tension is 100N (about 98kg); Allowable temperature range (fixed installation), -30℃~+70℃; Flame retardant performance, refer to IEC 60332-1-2 requirements The use of KNX/EIB bus control cable BUS EIB 2X2X0.8 | J-Y(st) Y 2X2X0.8: It is widely used in intelligent building management/control systems, such as distributed lighting control, heating, air conditioning, exhaust, energy management, blinds, time management, and locking systems. The cable can be laid up and down in the plaster, in the plaster, in the pipecable and in the cable tube, and is suitable for dry and humid indoors. EIB installation mainly includes: sensors (transmitting signals), such as light barriers, switches, humidistats, infrared, anemometers, timers, etc.; actuators, such as engines, heaters, ventilation, lighting, shading plates, etc. | ||