1.5kw 2kw 3kw 3.6kw 5kw wind power on grid inverter
Negotiable
Min.Order:1
1.5KW 2kw 3kw 3.6kw 5kw Grid tie inverter for wind turbine
Single phase output
Challentec type, Germany technical
With inside isolation transformer
Width DC voltage input range
Low start up voltage
1.5kw wind power grid tie inverter price is US$750.00/set
For other model price, pls contact with us.
1.) 1.5kw 2kw wind power grid tie inverter, single phase to grid
Model |
1.5KW |
2KW |
Input Parameter |
|
|
Range of MPPT Voltage (DC) |
40V - 450V |
|
Maximum Power of Turbine |
1600W |
2100W |
DC Voltage VPP |
VPP < 10 % |
|
Output Parameter |
|
|
Power Rating |
1500W |
2000W |
Range of Grid Voltage |
196 – 253V AC |
|
Range of Grid Frequency |
Choice of either 50Hz or 60Hz |
|
Power Factor |
> 0.99 |
|
Maximum Efficiency |
94% |
|
Standby Consumption |
< 11 W |
|
Protections |
Anti-island, Over Temperature,Over Load, Over Current,Over Voltage |
|
Total Harmonic Distortion (THD) |
< 4 % |
|
Mechanical Characteristics |
|
|
Dimensions W×H×D in mm |
555/420/125 |
|
Weight |
30kg |
32.5kg |
Protection Level |
IP20 |
|
Installation Method |
Wall-mounted |
|
Working Environment Temperature |
-20℃ ~+40℃ |
|
Storage Temperature |
-20℃ ~+50℃ |
|
Inverter Characteristics |
|
|
Cooling Method |
Cooling Fan |
|
Display |
LCD & Signal Lamps |
|
Communication |
RS485 |
|
Points of Power Curve |
Minimum 5,Maximum 20. |
|
EMC |
EN61000-6-1:2007 |
|
Safety Standard |
IEC 62103:2003(1st Edition) |
|
|
EN50178:1997 |
|
Grid Connecting Standard |
DIN VDE 0126-1-1:2006 |
2.) 3kw 3.6kw 5kw wind power grid tie inverter, single phase to grid
Model |
3KW |
3.6KW |
5KW |
Input Parameter |
|
||
Range of MPPT Voltage (DC) |
60V - 550V |
||
Maximum Power of Turbine |
3300W |
4000W |
5500W |
DC Voltage VPP |
VPP < 10 % |
||
Output Parameter |
|
||
Power Rating |
3000W |
3600W |
5000W |
Range of Grid Voltage |
190 – 260V AC |
||
Range of Grid Frequency |
Choice of either 50Hz or 60Hz |
||
Power Factor |
> 0.99 |
||
Maximum Efficiency |
94% |
||
Standby Consumption |
< 11 W |
||
Protections |
Anti-island, Over Temperature,Over Load, Over Current,Over Voltage |
||
Total Harmonic Distortion (THD) |
< 4 % |
||
Mechanical Characteristics |
|
||
Dimensions W×H×D in mm |
480/680/235 |
||
Weight |
56kg |
60kg |
67kg |
Protection Level |
IP65 |
||
Installation Method |
Wall-mounted |
||
Working Environment Temperature |
-25℃ ~+60℃ |
||
Storage Temperature |
-40℃ ~+70℃ |
||
Inverter Characteristics |
|
||
Cooling Method |
Fan & Convection |
||
Display |
LCD & Signal Lamps |
||
Communication |
RS485 |
||
Points of Power Curve |
Minimum 5,Maximum 20. |
3.) Wind generator on grid system simple diagram
4.) working shop
wind grid connecting inverter inside photo
Grid tie inverter packed with plywood case.
Safety packing: carton + plywood case
Provide professional technical support;
Provide system design;
Wind turbine type, model, capacity selection professional support;
Tower design, foundation design support;
Completely system provider and designer;
Support paypal payment, TT payment;
We started to manufacture wind turbine in 1994. In 2004, there are only 4 small wind turbine manufactures
in China. We keep improving and develop in the small wind turbine field. We are not the leading small wind
turbine exporter, but we are the leading wind turbine manufacture and designer now.
We manufacture 300w-30kw fixed pitch wind turbine;
2kw, 3kw, 5kw, 10kw, 20kw, 30kw, 50kw, 60kw pitch controlled wind turbine;
On grid system/off grid system, wind solar hybrid system; Water heating system;
For more details, pls contact with us via e-mail.
1. Wind turbine model selection
It depends your local annual average wind speed, daily/monthly home power consumption.
Low average wind speed place, select larger blades rotor, higher rated working voltage;
Rich wind place select speed limited wind turbine: variable pitch wind turbine, stall out vertical axis wind turbine.
The safety and steady working system is the first choice.
2. Wind turbine tower selection
Now we have guy wire tower, stand alone tower, tilting up tower, hydraulic tower.
Guy wire tower cost is lower, easy to delivery. But the installation area is larger;
Tilting up tower is for 500w-5kw wind turbine. Easy installation, small installation area. But the delivery cost is higher.
Hydraulic tower: It is used for no crane place. Easy installation and put down. The cost is higher.
Stand alone tower for the installation place with crane.
The tower height: Make sure blades rotor is higher than wind turbine surrounding barrier height.
3. Working system selection
On grid system: wind turbine with tower + PWM controller with dump load + grid tie inverter;
Off grid system: wind turbine with tower + PWM charge controller with dump load + battery group + inverter;
Wind solar hybrid on/off grid system: Safety and reliable than only wind or solar system.
Wind turbine water heating system: work in rich wind place. Average wind speed higher than 8m/s.
For more question, pls contact with us directly. We will give you a professional response.
Why select us:
We are the wind turbine designer and manufacture. We know our wind turbine advantage and disadvantage in different wind condition.
I have more than 10 years wind turbine sales experience. We provide the right wind turbine and working system to different user according to their different situation and request.
In 2004, there are 4 small wind turbine manufacture. Now there are so much trading company and manufacture, we know Chinese small wind turbine market well and can provide user more useful advise.