Grouted Connection Rebar Sleeve with non-grouting end Construion Metal Steel Splicing grouting rebar coupler
Negotiable
Min.Order:1
Metal Building Materials Precast Concrete Mechanical Coupling Threaded Quick Connector
Metal Building Materials And Real Estate Half Bar Sleeve Grout Rebar Coupler
Half Grouting Sleeve Steel Bar Connecting Sleeve Tunnel Subway Construction Grouting Rebar Coupler
Upsetting Straight Thread 12mm 32mm Grout Filled Rebar Steel Sleeve
Building Materials Bridge Semi-Grout Filled Rebar Splicing Coupler
Parameters Of Semi-grouting Sleeve For Steel Bar Connection-Building Specification(mm) | ||||||||||||||||
Grout Sleeve Model | Bar Diameter | Outer Diameter | Length | Grout Hole Center Position | The Hole Location Of The Outflow Slurry | Grout end connecting steel bar Twisting depth | Internal thread pitch | Internal thread profile angle | ||||||||
GTB4J-12 | Φ12 | 34 | 140 | 28 | 94 | 96 -116 | 2 | 75° | ||||||||
GTB4J—14 | Φ14 | 36 | 156 | 30 | 110 | 112 -132 | 2 | 75° | ||||||||
GTB4J-16 | Φ16 | 39 | 174 | 30 | 126 | 128 -148 | 2.5 | 75° | ||||||||
GTB4J-18 | Φ18 | 41 | 193 | 35 | 142 | 144-164 | 2.5 | 75° | ||||||||
GTB4J-20 | Φ20 | 43 | 211 | 40 | !58 | 160-180 | 2.5 | 75° | ||||||||
GTB4J-22 | Φ22 | 46 | 230 | 40 | 174 | 176-196 | 2.5 | 75° | ||||||||
GTB4J-25 | Φ25 | 52 | 260 | 40 | 198 | 200-220 | 3 | 75° | ||||||||
GTB4J-28 | Φ28 | 60 | 292 | 40 | 228 | 224-244 | 3 | 75° | ||||||||
GTB4J-32 | Φ32 | 66 | 330 | 40 | 263 | 256-275 | 3 | 75° | ||||||||
Note: 1. The bottom dimension in the table is the value of the sleeve raw material that meets the mechanical performance requirements of No. 45 steel in GB/T699-2015 (the measured yield strength and ultimate strength should not be less than J355-2015 Rebar Sleeve Grouting Connection Application Technology The standard specified in the regulations), the minimum size that can be selected when the sleeve manufacturer has a good level of quality control. 2. The minimum size of the measured sleeve should be measured in at least two directions, and the minimum value should be used for judgment. 3. The customer's special customized sleeve must meet the mechanical performance parameters (strength requirements) of the sleeve as a premise, and the size can be flexibly controlled. | ||||||||||||||||
Parameters of semi-grouted sleeves- bridge connection | ||||||||||||||||
Semi-grout Sleeve Model | Bar Diameter | Outer Diameter | Inner Diameter | Length | Grout Hole Center Position | The Hole Location Of The Outflow Slurry | On-site Construction Reinforcement Insertion Depth | Factory Installed Rebar Insertion Depth | ||||||||
GTB4J-32 | Φ32 | 70 | 53 | 394 | 28 | 94 | 96 -116 | 12.6 | ||||||||
GTB4J-36 | Φ36 | 78 | 57 | 440 | 30 | 110 | 112 -132 | 14.6 | ||||||||
GTB4J-40 | Φ40 | 89 | 65 | 480 | 30 | 126 | 128 -148 | 16.6 |
After-sales service | On-site service is available |
Product raw materials | No.45 high quality carbon structural steel |
Product application scope | Building, bridge, etc |
Product model | GTJB4 |
Product appearance color | silver |
Product packaging | The wooden case |