Product Description
Feature:
Large LCD screen(480*272 Dots) with 65 thousand true color and support U disk data saving
Imported & Environmental Deuterium lamp, preventing from Ozone inhalation
Data output: Data can be exported to U disk (USB Output)
Print port: Instrument can connect PCL printer for printing A4 paper (USB Port)
Adopted high-class grating with wholly hermetic light path design, to ensure the instrument has the super low stray light
Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system
Pre-aligned design ensures the user can change lamps conveniently
With GLP self-check function, check the wavelength accuracy and Photometry accuracy, can provide test report and power-off
protection
Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
With Si02 coating optical mirror, reducing the pollution from outside fully
Imported & Environmental Deuterium lamp, preventing from Ozone inhalation
Data output: Data can be exported to U disk (USB Output)
Print port: Instrument can connect PCL printer for printing A4 paper (USB Port)
Adopted high-class grating with wholly hermetic light path design, to ensure the instrument has the super low stray light
Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system
Pre-aligned design ensures the user can change lamps conveniently
With GLP self-check function, check the wavelength accuracy and Photometry accuracy, can provide test report and power-off
protection
Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
With Si02 coating optical mirror, reducing the pollution from outside fully
Specification
Model | BK-UV1800 BK-UV1800PC | BK-UV1600 BK-UV1600PC | BK-V1800 BK-V1800PC | BK-V1600 BK-V1600PC | |||||||||||
Optical System | Single Beam, Grating 1200 lines/mm | ||||||||||||||
Wavelength Range | 190~1100nm | 320-1100nm | |||||||||||||
Spectral Bandwidth | 2nm | 4nm | 2nm | 4nm | |||||||||||
Wavelength Accuracy | ± 0.5nm | ||||||||||||||
Wavelength Repeatability | ≤ 0.3nm | ||||||||||||||
Photometric Accuracy | ± 0.002A (0~0.5Abs), ± 0.004A (0.5~1.0Abs), ± 0.5% T (0~100% T) | ||||||||||||||
Photometric Repeatability | 0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤ 0.2% T (0~100% T) | ||||||||||||||
Stray Light | ≤ 0.05% T 360nm; 220nm | ≤ 0.05% T 360nm;220nm | |||||||||||||
Stability | ± 0.001A / h 500nm | ||||||||||||||
Baseline Flatness | ± 0.002A | ||||||||||||||
Noise | ± 0.0005A | ||||||||||||||
Display | 480 * 272 65 thousand true color TFT LCD | ||||||||||||||
Photometric Mode | T, A, C, E | ||||||||||||||
Photometric Range | 0~200% T, -0.301~3.0A | ||||||||||||||
Detector | Silicon Photodiode | ||||||||||||||
Light Source | Deuterium Lamp, Tungsten Lamp | ||||||||||||||
Input | Membrane Keypad | ||||||||||||||
Output | USB Print and data output, Connect PC | ||||||||||||||
Standard Accessories | 10mm glass cuvette *4 units 10mm quartz cuvette *2 units | 10mm glass uvette *4 units | |||||||||||||
Optional Accessories | Single cell holder,General cell holder,Test tube holder,Solid sample holder,Deuterium lamp,Halogen lamp,4-place Cell holder,Printer,Water-jacketed cell holder,Reflection accessory 5°,Auto 8-cell changer,Micro cell holder,Water-jacketed cell holder,Constant-temperature system | 4-place Cell holder,Printer, Test tube holder,Deuterium lamp,Halogen lamp | |||||||||||||
Power Supply | AC110V/220±10% ,60/50Hz | ||||||||||||||
Packing Size(mm) | 620*500*370 | 620*500*370 | 620*500*370 | 620*500*370 | |||||||||||
Gross Weight(kg) | 18 | 18 | 16.5 | 16.5 |