BIOBASE GROUP adheres to the mission of “SERVICE FOR HEALTH FOR THE FUTURE”
We provide with high quality products and best service!
Product Show
BK6500 Auto 5 parts Hematology analyzers are used to run tests on blood samples. They are used in the medical field to do white blood cell counts, complete blood counts, reticulocyte analysis.
Features:
1.Laser scatter technology.
2.Constant linear sheath flow.
3.3-D topographic technology.
4.Auto-loader, 60 samples/hour.
5.Integral titanium incubation system.
6.28 parameters, 2 histograms, 2 scattergrams.
7.Random direction tube barcode scanning technology (optional).
2.Constant linear sheath flow.
3.3-D topographic technology.
4.Auto-loader, 60 samples/hour.
5.Integral titanium incubation system.
6.28 parameters, 2 histograms, 2 scattergrams.
7.Random direction tube barcode scanning technology (optional).
Technical Parameters
Model | BK-6500 | ||||||
Throughput | 60Tests/hour | ||||||
Assay Items | 5 parts, 28 parameters, 2 histograms, 2 scattergrams | ||||||
Test mode | CBC+5DIFF, CBC | ||||||
Measuring Principle | Laser Scatter Technology | ||||||
Sample Modes | Autoloader: 50 tubes, auto mixing, random direction tube barcode scanning technology | ||||||
Close tube: STAT priority, support both whole blood and capillary blood samples | |||||||
Testing Items | Regular Parameters:WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, EOS#, EOS%, BAS#, BAS% Research Parameters:ALY#, ALY%, IG#, IG% | ||||||
Linearity Range | Item | Linear range | Carry over | CV | |||
WBC | 1.0~99.9x10^9/L | ≤0.5% | ≤2.0% | ||||
RBC | 0.3~7.0x10^12/L | ≤0.5% | ≤1.5% | ||||
HGB | 20~240g/L | ≤0.5% | ≤1.5% | ||||
PLT | 20~999x10^9/L | ≤1.0% | ≤4.0% | ||||
Storage | 100,000 results storage including histogram and scattergram | ||||||
LIS Interface | Support HL7 protocol | ||||||
QC and Calibration | Multiple QC rules,including L-J,X-B etc. Auto and manual calibration funtion | ||||||
Incubation | Integral titanium incubation system | ||||||
Multi-warning | Reagent inventory check; Abnormal original data warning; Multi warning flags | ||||||
Power supply | AC220V±10% 50/60Hz; 110V±10% 60Hz; 600VA | ||||||
Computer | External optional | ||||||
Package Size | 712*587*730mm(W*D*H) | ||||||
Gross Weight | 104kg | ||||||
ReagentPackage Size | 320*320*300mm (W*D*H);340*290*280mm (W*D*H) | ||||||
ReagentGross Weight | 24kg |