CZ3000 Temperature Converter Signal Conditioner

CZ3000 Temperature Converter Signal Conditioner

CNY 200 - 2000 /Piece

Min.Order:1 Piece

Supply Ability:
2147483647 Piece / Pieces per Month
Payment Terms:
T/T
Delivery Detail:
7 days

Shanghai Chenzhu Instrument Co., Ltd.

Business license
Shanghai China
Main Products: low voltage surge protection device ,safety automation system ,galvanic isolation barrier

Product Details

CZ3000 Temperature Signal Conditioner

Thermal resistance type signal isolators, the two-wire or three-wire system resistance signal is converted into 0/4~20mA current signal isolation or 0/1~5V voltage signal output. It is intelligent, can through the computer scope of heat resistance index number range and configuration.

 

This 5v to 24v signal converter should be supplied power independently. Input circuit, output circuit and power supply are each galvanically isolated.

 

Advantages of CZ3000 Temperature Converter Signal Conditioner

24V DC independent/ loop power supply

 

Line fault detection(LFD)

 

Configurable by software

 

Integral CJC on terminals/TC input terminals

 

Parameter of CZ3000 Temperature Converter Signal Conditioner


CZ3076

CZ3079


CZ3071

1/2

2/2


1/1




Input Signal

Pt100Cu100Cu50

Pt100Cu100Cu50

Pt100Cu100Cu50

Output Current/Load Resistance

0~20mA4~20mA / RL ≤300Ω

0~20mA4~20mA / RL ≤300Ω

0~20mA4~20mA / RL ≤300Ω

Output Voltage/Load Resistance

0~5V1~5V / RL ≥20kΩ

0~5V1~5V / RL ≥20kΩ

0~5V1~5V / RL ≥20kΩ

Fault Current of Overrange/Underrange

IH≈20.8mA/IL≈3.8mA

IH≈20.8mA/IL≈3.8mA

IH≈20.8mA/IL≈3.8mA

Fault Current of Line Break

I≈20.8mA

I≈20.8mA

I≈20.8mA

Supply Voltage

20~35V DC

20~35V DC

20~35V DC

Power Reverse Protection

Support

Support

Support

Current Consumption(Supply voltage:24V)

≤35mA

≤55mA

≤55mA

Temperature Drift

0.01%F.S./℃

0.01%F.S./℃

0.01%F.S./℃

Response Time (0~90%)

≤1s

≤1s

≤1s

Dielectric Strength

1500V AC;1min

1500V AC;1min

1500V AC;1min

Insulation Resistance

≥100MΩ; 500V DC

≥100MΩ; 500V DC

≥100MΩ; 500V DC

EMC Standards

GB/T 18268(IEC 61326-1)

GB/T 18268(IEC 61326-1)

GB/T 18268(IEC 61326-1)

Ambient Temperature

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

Suitable Field Apparatus

2-or 3-wire RTD

2-or 3-wire RTD

2-or 3-wire RTD






CZ3072

CZ3074

CZ3079.TC

1/1

1/2

2/2

Input Signal(Customized mV signal)

TEJKNRSB

TEJKNRSB

TEJKNRSB

Internal CJC Temperature Range

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

CJC Precision

±1℃

±1℃

±1℃

Output Current/Load Resistance

0~20mA4~20mA / RL≤300Ω

0~20mA4~20mA / RL≤300Ω

0~20mA4~20mA / RL≤300Ω

Output Voltage/Load Resistance

0~5V1~5V / RL ≥20kΩ

0~5V1~5V / RL ≥20kΩ

0~5V1~5V / RL ≥20kΩ

Fault Current of Overrange/Underrange

IH≈20.8mA/IL ≈3.8mA

IH≈20.8mA/IL ≈3.8mA

IH≈20.8mA/IL ≈3.8mA

Fault Current of Line Break

I≈20.8mA

I≈20.8mA

I≈20.8mA

Supply Voltage

20~35V DC

20~35V DC

20~35V DC

Power Reverse Protection

Support

Support

Support

Current Consumption(Supply voltage:24V)

≤35mA

≤55mA

≤55mA

Temperature Drift

0.01%F.S./℃

0.01%F.S./℃

0.01%F.S./℃

Response Time (0~90%)

≤1s

≤1s

≤1s

Dielectric Strength

1500V AC;1min

1500V AC;1min

1500V AC;1min

Insulation Resistance

≥100MΩ; 500V DC

≥100MΩ; 500V DC

≥100MΩ; 500V DC

EMC Standards

GB/T 18268(IEC 61326-1)

GB/T 18268(IEC 61326-1)

GB/T 18268(IEC 61326-1)

Ambient Temperature

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

Suitable Field Apparatus

TC and mV signal sensor

TC and mV signal sensor

TC and mV signal sensor






1/1CZ3077

1/1CZ3177

1/1CZ3277

2/2CZ3078

2/2CZ3178

2/2CZ3278

Input Signal

Pt100Cu100Cu50

TEJKNRSB

Pt100Cu100Cu50

(Customized mV signal)

TEJKNRSB

Internal CJC Temperature Range


-20~+60℃

-20~+60℃

CJC Precision


±1℃

±1℃

Output Current

4~20mA

4~20mA

4~20mA

Load Resistance

RL ≤(Ue -12)/0.021Ω

RL ≤(Ue -12)/0.021Ω

RL ≤(Ue -12)/0.021Ω

Fault Current of Overrange/Underrange

IL ≈20.8mA/IL ≈3.8mA

IL ≈20.8mA/IL ≈3.8mA

IL ≈20.8mA/IL ≈3.8mA

Fault Current of Line Break

I≈20.8mA

I≈20.8mA

I≈20.8mA

Loop Supply Voltage(Ue)

12~30V DC

12~30V DC

12~30V DC

Power Reverse Protection

Support

Support

Support

Temperature Drift

0.01%F.S./℃

0.01%F.S./℃

0.01%F.S./℃

Response Time (0~90%)

≤1s

≤1s

≤1s

Dielectric Strength

1500V AC;1min

1500V AC;1min

1500V AC;1min

Insulation Resistance

≥100MΩ; 500V DC

≥100MΩ; 500V DC

≥100MΩ; 500V DC

EMC Standards

GB/T 18268(IEC 61326-1)

GB/T 18268(IEC 61326-1)

GB/T 18268(IEC 61326-1)

Ambient Temperature

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

Suitable Field Apparatus

2-or 3-wire RTD

TC sensormV signal

RTDTC sensor

 

Signal conditioners are electrical devices, which are connected between the industrial field instrument and the control room. CHENZHU's signal conditioner complete in specifications.

 


Contact Supplier

Ms. Danping Li Director Chat Now
Telephone
86-021-64513350
Mobile
86-18121270322
Address
8F, Bldg.6, No. 201, Minyi Road, Songjiang Dis Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~