CLCYDS730 Digital Dissolved Ozone Sensor Electrode principle characteristics:Constant voltage principle electrode is used to measure dissolved ozone or hypochlorous acid in water. The constant voltage measurement method is to maintain a stable potential at the electrode measuring end, and different measured components produce different current intensities under this potential. It consists of two platinum electrodes and a reference electrode to form a micro current measurement system. The dissolved ozone or hypochlorous acid in the water sample flowing through the measuring electrode will be consumed. Therefore, the water sample must be kept flowing continuously through the measuring electrode during measurement.The constant voltage measurement method uses a secondary instrument to continuously and dynamically control the potential between the measuring electrodes, eliminating the inherent resistance and oxidation-reduction potential of the measured water sample, so that the electrode can measure the current signal and the measured water sample concentration A good linear relationship is formed between them, with a very stable zero point performance, ensuring accurate and reliable measurement.The constant voltage electrode has a simple structure and a glass appearance. The front end of the online residual chlorine electrode is a glass bulb, which is easy to clean and replace. When measuring, it is necessary to ensure that the water flow rate through the dissolved ozone measuring electrode is stable.This product is a digital sensor that integrates electronic circuits and microprocessors inside the sensor, referred to as digital electrode.Constant voltage residual chlorine digital electrode sensor (RS-485) Features1. Power supply and output isolation design to ensure electrical safety2. Built-in protection circuit for power supply and communication chip, strong anti-interference ability3. With comprehensive protection circuit design, it can work reliably without additional isolation equipment4. The circuit is built inside the electrode, which has good environmental tolerance and easier installation and operation5. RS-485 transmission interface, MODBUS-RTU communication protocol, two-way communication, can receive remote commands6. The communication protocol is simple and practical and extremely convenient to use7. Output more electrode diagnostic information, more intelligent8. The internal integrated memory can still memorize the stored calibration and setting information after power off9. POM shell, strong corrosion resistance, PG13.5 thread, easy to install.Application:Drinking water: ensuring reliable disinfectionFood: to ensure food safety, sanitary bag and bottle methodsPublic works: detection of residual chlorinePool water: efficient disinfectant No additional instrument is required, 485 signal transmission, no interference on site, easy to integrate into various systems, and effectively reduce related use costs.The electrodes can be calibrated in the office or laboratory, and replaced directly on site, without additional on-site calibration, which greatly facilitates later maintenanceCalibration information record is stored in electrode memory.
CLCYDS730 Digital Dissolved Ozone Sensor Electrode
Model No.: CLCYDS730
Power/Outlet: 12VDC/RS485 MODBUS RTU
Measurement method: Potentiostatic
Housing material: Glass+POM
Waterproof rating: IP68
Measurement range: 0-2mg/L;0-10mg/L;0-20mg/L
Accuracy: ±1%F.S
Pressure resistance: ≤0.3Mpa
Temperature compensation: NTC10K
Temperature range: 0-80ºC
Measuring/Storage Temperature: 0-45ºC
Calibration: Sample calibration, standard liquid calibration
Connection methods: 4 core cable
Cable length: Standard 5m cable, can be extended to 100m
Installation thread: PG13.5
Application: Drink water, pool water, etc.