Product Description
Mitsubishi ElectricMelsec iQ-F Series
iQ Platform-compatible PLC FX2N
FX Series in the compact body built in superior performance, and strive to operate simple.
In addition, rich options can meet the various needs of customers.
In the virtual factory will be rich in the function of a part of the introduction.
It is easy to control the analog quantity of the application.
Can be extended to all models in the FX series analog devices.
Function extension board, special adapter without programming can be used for communication.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V.
The number of connection points depends on the basic unit and the expansion unit.
In addition, rich options can meet the various needs of customers.
In the virtual factory will be rich in the function of a part of the introduction.
It is easy to control the analog quantity of the application.
Can be extended to all models in the FX series analog devices.
Function extension board, special adapter without programming can be used for communication.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V.
The number of connection points depends on the basic unit and the expansion unit.
Specification
Model : | FX2N-8EYT | FX5U-32MR/ES | |
Type: | Transistor output module | CPU module | |
Total input and output points: | 8 points | 32 points | |
Output points: | 8 points. | ||
Output type: | transistor output. |
Selecting the FX5UC Model
Type | Details | Connection details, model selection |
CPU module | PLC with built-in CPU, power supply,input/output and program memory. | Various expansion devices can be connected. |
I/O module | Product for expanding I/O. Some products are powered. | Input/output can be expanded to up to 256 points. (Expansion module: Max. 16 modules (excluding extension power supply module)).The total with CC-Link remote input/output is max. 512 points. |
FX5 extension power supply module | Module for expanding power supply if CPU module’s internal power supply is insufficient. Extension cable is enclosed. | Power can be supplied to I/O module, intelligent function module, and bus conversion module. Up to 2 modules can be connected. |
I/O module | Product for expanding I/O. Some products are powered. | Input/output can be expanded to up to 256 points. (Expansion module: Max. 16 modules (excluding extension power supply module)).The total with CC-Link remote input/output is max. 512 points. |
FX5 intelligent function module | Module with functions other than input/output. | Up to 16 expansion modules including the I/O module can be connected (excluding the extension power supply module). |
Bus conversion module | Conversion module for connecting FX3 Series expansion module. | FX3 Series expansion module can be connected only to the right side of the bus conversion module |
FX5 expansion board | Board connected to front of CPU module to expand functions. | Up to 1 module can be connected to the front of the CPU module. (Expansion adapter can also be used.) |
FX5 expansion adapter | Adapter connected to left side of CPU module to expand functions. | Up to 6 modules can be connected to the left side of the CPU module |
FX3 extension power supply module | Module for expanding power supply if CPU module’s internal power supply is insufficient. | The bus conversion module is required for use. Up to 2 modules can be connected. |
FX3 intelligent function module | Module with functions other than input/output. | The bus conversion module is required for use. When using the FX3 extension power supply module, up to 8 modules 4 can be used.When not using the FX3 extension power supply unit, up to 6 modules 4 can be used. |
Model options
FX5U CPU Modules | FX5U-32MR/ES | FX5U-32MT/ES | FX5U-32MT/ESS | ||
FX5U-64MR/ES | FX5U-64MT/ES | FX5U-64MT/ESS | |||
FX5U-80MR/ES | FX5U-80MT/ES | FX5U-80MT/ESS | |||
Communication | FX5-232ADP | FX5-485ADP | |||
Analog | FX5-4AD-ADP | FX5-4DA-ADP | |||
FX5 Expansion Boards | FX5-232-BD | FX5-485-BD | FX5-422-BD-GOT | ||
Powered I/O Modules | FX5-32ER/ES | FX5-32ET/ES | FX5-32ET/ESS | ||
FX5-8EX/ES | FX5-16EX/ES | FX5-8EYR/ES | |||
FX5-8EYT/ES | FX5-8EYT/ESS | FX5-16EYR/ES | |||
FX5-16EYT/ES | FX5-16EYT/ESS | ||||
Intelligent Function Modules | FX5-40SSC-S | ||||
Extension Power Supply Module | FX5-1PSU-5V | ||||
Bus Conversion Module | FX5-CNV-BUS | ||||
Battery | FX3U-32BL | ||||
NZ1MEM-2GBSD (2 GB) | |||||
NZ1MEM-4GBSD (4 GB) | |||||
Programming software | GX Works3 | ||||
Extension Power Supply Module | FX3U-1PSU-5V | ||||
Analog | FX3U-4AD | FX3U-4DA | |||
Positioning | FX3U-1PG | ||||
Network | FX3U-64CCL | FX3U-16CCL-M | |||
Temperature control | FX3U-4LC | ||||
High Speed counter | FX3U-2HC |