10000kVA/600kV Variable Frequency Resonant (VF) Test System-Solution Brief

10000kVA/600kV Variable Frequency Resonant (VF) Test System-Solution Brief

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
1 Piece / Pieces per Month

Shanghai Launch Electric. Ltd

Business license
Business Type: Other
Shanghai China
Main Products: Non-standard complete set of equipment ,complete set of impulse voltage generatorapplications ,Hydraulic Parts ,high voltage capacitive voltage divider ,resonant testing equipment ,complete set of gas&oil-gas test equipment ,complete set of DC high voltage generator ,complete set of impulse current generator ,test equipment for training on-line operation on analog grid ,high voltage reactor ,special test equipment

Product Details

Contact US

Email:info@launch-electric.com

Product Overview

Test Object and Requirement

The system is specially designed for AC withstand voltage test for below items, with below specifications and requirements.

Test Object

Specifications

Test Frequency

Test Voltage

Test Time

Power cable

170kV/2000mm2/10km

Capacitance ≤2μF

30-300Hz

150kV

15 mins

Power cable

400kV/2000mm2/5km

Capacitance ≤0.6μF


30-300Hz

220kV

15 mins

GIS

400kV and below Capacitance ≤0.02μF

30-300Hz

Max. 750kV



Features

Capacity Determination of the equipment:

4pcs Reactors will be designed, each reactor is 2500 kVA/150kV. Capacity amount is 10000kVA.

Determination:

1) When to do AC withstand voltage testing on 170kV 2000mm2 10kM power cable.

Using 4pcs reactors in paralleled.

Output 150kV/66.6A, testing current is calculated as below:

I=U×103×ω×C×106=66A (U:150kV,C:2uF,ω=2πf (f=35Hz))

2) When to do AC withstand voltage testing on 400kV 2000mm2 5kM power cable,

Using 2pcs reactors in series and then these two groups in paralleled.

Output 300kV/33.3A, testing current is calculated as below:

I=U×103×ω×C×106=29A (U:220kV,C:0.6uF,ω=2πf (f=35Hz))

3) When to do AC withstand voltage testing on 400kV and below voltage degree GIS and etc. equipment, the capacitance is 0.02 uF,

Using 4pcs reactors in series, output 600kVA/16.6A, resonant frequency and testing current is calculated as below:

I=U×103×ω×C×10-6=3.3A (U:512kV,C:0.02uF,ω=2πf (f=50Hz))


REACTORS


TEST OBJECT

Testing Voltage (kV)

REACTOR 2500KVA/150kV

OUTPUT VOLTAGE OF EXCITING TRANSFORMER

170KV Power Cable

150

4 pcs reactors in paralleled

7.5KV

400KV Power Cable

220

2 pcs reactors in series, then two groups in parralled

15kV

400kV GIS

512

4 pcs in series

30kV

Specifications

No.

Name

Module No. & Specs

Quantity

1

Exciting Transformer

SXJB-500kVA/7.5kV/15kV/30kV/

1 set


2

Variable frequency power supply

SXBP-500kW/380V/220V

1 set

3

HV Reactor

SXDK-2500kVA/150kV

4 pcs

4

Capacitive Divider

SXFR-150 kV -1000 pF

1 set

5

Connecting Cable

Accessories are as Table I.

1 set

6

Factory Test Report


1 copy

7

User's Guide


1 copy


Contact Supplier

Mr. wang ceo Chat Now
Mobile
86-15821234022
Skype
info@launch-electric.com
Address
hongkou Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Measuring & Analysing Instrument Design Services
Categories
Hi~