Impulse voltage generator test system,impulse current generator system,lightning impulse test
Impulse voltage generator test system,impulse current generator system,lightning impulse test

Impulse voltage generator test system,impulse current generator system,lightning impulse test

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
1 Piece / Pieces per Month

Shanghai Launch Electric. Ltd

Business license
Business Type: Other
Shanghai China
Main Products: Non-standard complete set of equipment ,complete set of impulse voltage generatorapplications ,Hydraulic Parts ,high voltage capacitive voltage divider ,resonant testing equipment ,complete set of gas&oil-gas test equipment ,complete set of DC high voltage generator ,complete set of impulse current generator ,test equipment for training on-line operation on analog grid ,high voltage reactor ,special test equipment

Product Details

Contact US

Email:info@launch-electric.com

Products Description


Components and accessories

1.Impulse Generator main body
2.Charging Rectifier
3.Impulse Voltage Divider
4.Control System
5.Impulse Analyzer –oscilloscope
6. Shunts
7.Chopping Gaps



Main Feature

1.Easy to configure 2.Fast & unique grounding system 3.Mobile on castors 4.Fiber optic connection to the HV section 5.Maximum reduction of risk. High safety

Application

The system can be used to generate impulse voltages simulating lightning strokes and switching surges according to IEC,ANSI/IEEE as well as other national standards

Technical Parameters

1.Capacitance per stage: 0.5μF 10kJ/stage or customized 2.Voltage per stage: 100kV or customized 3.Output waveform (when the load is less than 3000pF): ±1.2/50μs standard lightning impulse voltage full wave, with efficiency above 90% 2-6μs chopping wave (equipped with multi-stage chopping equipment) 4.Synchronization range: above 20% 5.Duration: Continuous work is allowed when it is running at less than 80% of its rated operational voltage It can work at intervals when it is running at more than 80% of its rated operational voltage 6. Amplitude adjustment deviation is less than 1%, and the minimum output voltage is not more than 10% of the nominal voltage. 7.Synchronization difference: less than 1%


Contact Supplier

Mr. wang ceo Chat Now
Mobile
86-15821234022
Skype
info@launch-electric.com
Address
hongkou Shanghai

You May Like