Impulse voltage generator test system,impulse current generator system,lightning impulse test
Negotiable /Piece
Min.Order:1 Piece
Contact US
Email:info@launch-electric.com
Products Description
1.Easy to configure 2.Fast & unique grounding system 3.Mobile on castors 4.Fiber optic connection to the HV section 5.Maximum reduction of risk. High safety
The system can be used to generate impulse voltages simulating lightning strokes and switching surges according to IEC,ANSI/IEEE as well as other national standards
Technical Parameters
1.Capacitance per stage: 0.5μF 10kJ/stage or customized 2.Voltage per stage: 100kV or customized 3.Output waveform (when the load is less than 3000pF): ±1.2/50μs standard lightning impulse voltage full wave, with efficiency above 90% 2-6μs chopping wave (equipped with multi-stage chopping equipment) 4.Synchronization range: above 20% 5.Duration: Continuous work is allowed when it is running at less than 80% of its rated operational voltage It can work at intervals when it is running at more than 80% of its rated operational voltage 6. Amplitude adjustment deviation is less than 1%, and the minimum output voltage is not more than 10% of the nominal voltage. 7.Synchronization difference: less than 1%