Supercritical Co2 extractor for oil production line
Negotiable
Min.Order:1
Sino Pharmaceutical Equipment Development (Liaoyang) Co., Ltd.
Model | HA120-50-01 |
Max. extract pressure | 50MPa |
Single extract cylinder volume | 1L |
Extraction temperature | Room temp – 75℃ |
Max. flow | 0-50L/h(adjustable) |
Kettle material | 1Cr18Ni9Ti |
Separation kettle volume | 600ml * 2sets |
Separation kettle pressure | 30MPa |
CO2 store tank volume | 3L |
CO2 store tank pressure | 16MPa |
Dimension | 1700*1520*1000mm |
Weight | 300KG(Approximate) |
NO | MAIN CONFIGURATION | PARAMETER | ||
1 | Extraction Kettle | 1L, 2L, 5L/50Mpa, 10L, 24L/40Mpa, 50-200L/32Mpa, Dual purpose for solid and liquid, equipped with water jacket for circulated heating with adjustable temperature. | ||
2 | Separation Kettle | 0.3-10L/Mpa, 50-100L/16-22Mpa, Equipped with water jacket for circulated heating with adjustable temperature. | ||
3 | Fine Distillation Column | inner diameter 25X2-3m/30Mpa,35X2-3m/30Mpa, 48X4-6m/30Mpa, 78X4-6m/30Mpa According to technological requirement, 4-section, 6-section or 8-section temperature control are available and relative stuffing can be selected and loaded by customer according to technological requirement. | ||
4 | High Pressure Pump | 20L/40Mpa.h double-plunger, 50L/50Mpa.h double-plunger frequency-modulating, 400L/40Mpa.h three-plunger frequency-modulating, 800l/40Mpa.h three-plunger frequency-modulating, the pump head application. | ||
5 | Take Pump | in the course of extraction, the entraner is used to change polarities of CO2 so as to extend range of application. | ||
6 | Cooling System | equipped with semi-sealed or full-sealed compressor to meet technological requirement. | ||
7 | Heat Exchange and Temperature Control System | according to technological requirement, the heat exchange and temperature control system are equipped for extraction kettle, separtion kettle and fine distillation column respectively to control the temperature of water circulation at -85℃ and the temperature pf oil circulation at -150℃; the digital display double-screen is used to control the temperature of water bath and to measure the temperature of CO2 fluid with accuracy of temperatire control at ±1℃. | ||
8 | Pressure Control (Protection) | equipped with the electro connecting pressure gauge at the outlet of the high pressure pump and set the working prssure to release pressure and make automatic protection in case overpressure occurs; equipped with safety valves for high pressure pump, extraction kettle, separtio kettle, fine distillation column according to their maximum working pressure to release pressure and make automatic protection in case overpressure occurs; equipped with back-pressure valve system at the outlet of the extraction kettle which has stable pressure and is easy to make adjustment. The control accuracy of pressure (dynamic) is ± 0.1MPa. | ||
9 | Display of Flow | the metal rotor flow meter with remote transferable digital display for instant flow and accumulated flow respectively. | ||
10 | Pipelines | all containers, valves, pipe fittings and pipelines contacting with fluid are all made of stainless steel. | ||
11 | Others | three-phase-four-wire power supply with 380V/50Hz and CO2 with foodstuff grade ≥99.5% are prepared by customer itself. |
Model | Extraction Capacity | Pressure | Combined Type | Dimension(mm) |
HA 120-50-01 | 1L | 50Mpa | one extracting pot-two separating pot | 2600*2600*1800 |
HA 120-50-05 | 5L | 50Mpa | one extracting pot-two separating pots-one column | 2600*2600*1800 |
HA 120-50-10 | 10L | 50Mpa | one extracting pot-two separating pots-one column | 3200*2600*1800 |
HA 120-50-20 | 10L*2 | 50Mpa | one extracting pot-two separating pots-one column | 3200*2600*1800 |
HA 120-50-48 | 24L*2 | 50Mpa | two extracting pot-two separating pots-one column | 5500*3500*4500 |
HA 120-50-100 | 50L*2 | 50Mpa | two extracting pot-two separating pots-one column | 6000*6000*4500 |