China Factory Redefining solar PV Connector For Solar Panel
Negotiable
Min.Order:1
Solar Connector
*Photovoltaic cable coupler.
*Due to highly robustness,UV-Resistance,the touch protection a high grade connection is guaranteed for 25 years.
*Acc.to DIN V VDE V 0126-3/12.06,UL1703 standard.
Technical Data of Solar Connector:
Type:R4 | |
Electrical Features: | |
Rated Current | 22A(2.5mm2), 35A(4mm2),40A(6mm2) |
Withstanding Voltage | 1500V DC(IEC),1000V/1500V DC(UL) |
Contact Resistance | ≤0.3mΩ |
Protection Class | Class II |
Mechanical Features: | |
Temperature Range | -40 ºC~+90ºC |
Protection Degree | IP2X,unmated;IP68,mated |
Wire Size Range | 2.5/4/6mm2(14AWG,12AWG,10AWG) |
Unmating Force | 200 Newton |
Material Features: | |
Insulation Material | PC |
Contact Material | Copper,Tin plated |
Flame Class | UL94-V0 or UL94-5VA |
Advantages of Solar Connector:
•Simple,quick,safe and effective filed assembly
• Develop independently,innovative design,have independent intellectual property rights,adaptive to solar connector directly
•High mechanical endurance
•Low transition resistance
•Innovative sealed,waterproof,dust resistance design:IP68
•Excellent plastic material ,UL 94-V0,wide temperature range:-40°c to 90°c,weather and UV resistant for long-time outdoor application
•Approved by TUV
Assembly instructions for connector of PV-R4C/...Especially
•During self assembly ,parts and tools other those stated by R&X are used or if the preparation and assembly instructions described here are disregarded then neither safety nor compliance with the technical data can be guaranteed.
•For protection against electric shock ,PV Connectors must be isolated from the power supply while being assembled or disassembled
•The end product must provided protection from electric shock
•Unplugging under load:PV plug connections must not be unplugged while under load.They can be placed in a no load state by switching off the DC/AC converter or breaking the AC circuit interrupter.Plugging and unplugging while under voltage is permitted
•Disconnected connectors should be protected from dirt and water with sealing caps.
•Plugged parts are watertight IP68
Touch Protection,mated/unmated IP68/IP2X | Rated Current 22A(2.5mm2) ,35A(4mm2) ,40A(6mm2) | |
Amblient temperature -40°c ~85°c | Roted voltage 1500V DC | |
Safety class ll | ||
Type | Crimping Ranges | |
mm2 | AWG | |
PV-R4C/F-1 | 2.5/4.0 | 14/12 |
PV-R4C/M-1 | 2.5/4.0 | 14/12 |
PV-R4C/F-2 | 4.0/6.0 | 12/10 |
PV-R4C/M-2 | 4.0/6.0 | 12/10 |
Assemble the cable and connector
(Picture 1&2)
Push the crimped contact into the socket resp.Plug insulator until it engages .
Pull lightly on the lead to check that the metal part has engaged.
Screw on the cable gland ,hand-light,with the tools PV-STX,tightening torque about:2.2Nm.
Plugging
(Picture3)
Mount the connector together until they engage.
Check correct engagement by Pulling on the coupling.
Unplugging
(Picture 4&5)
Compress the two snap-in springs by hand or with PV-STX tool and separate the coupling