Better Stability Automobile Exhaust Emission Tester Gas Analyzer Cleanable NDIR Gas Chamber
Negotiable /Piece
Min.Order:1 Piece
Cubic Sensor and Instrument Co.,Ltd.
Introduction
Gasboard—5020 emission gas analyzer is used for measuring the concentration of automobile emission gases CO ,CO2 ,HC ,O2 and NOx (optional). It is designed based on dual beam non-dispersion infrared (NDIR) principle, complied with latest national standard GB 18285, as well as ISO 3930 or OIML R99 Class 1, 0, 00 standards, applicable to the measurement of engine exhaust gas composition fueled by gasoline, LPG, CNG, etc.
Features
1. NDIR gas bench with regulated temperature system, high accuracy, better stability
2. Extended O2 and NOx sensors
3. Cleanable NDIR gas chamber
4. Built-in printer for real data printing
5. User-friendly PC software
Specifications
Measurements | HC CO CO2 NOx O2 |
Range | HC: (0~20000) ppm ; CO: (0.00-15.00) %; CO2: (0.00-20.00) %; NOx: (0~5000)ppm; O2: (0.00-25.00)% |
Accuracy | HC: (0~5000) ppm:Abs. error: ±10ppm;Rel. error:±5%; (5001~20000)ppm:Rel. error:±10% CO: (0~10.00) %:Abs. error: ±0.03 %;Rel. error:±3%; (10.01~14.00) %:Rel. error:±10% CO2: (0~20.00)%:Abs. error:±0.4×%;Rel. error:±4%;NOx: (0~4000) ppm:Abs. error:±25ppm;Rel. error:±4%; (4001~5000) ppm:Rel. error:±8% O2: (0~25.00) %:Abs. error:±0.1%;Rel. error:±3% *Remark:Abs. error or rel. error whichever is greater |
Warm-up Time | 10min |
Communication | RS-485/RS-232 |
Power supply | 100~240VAC,80W |
Display | LCD display |