Multi-parameter Patient Monitor for Infant

Multi-parameter Patient Monitor for Infant

Negotiable /Piece

Min.Order:10 Pieces

Supply Ability:
2000 Piece / Pieces per Month
Payment Terms:
T/T

Quick Details View All >

Place of Origin:
China
Model Number:
NIC-YD801
Type:
Infant Care Equipments

Henan Xingda Medical Equipment Manufacture CO., LTD

Business license
Business Type: Manufacturer
Main Products: Hospital Bed ,NICU Product ,Hospital Trolley ,Hospital Cabinet ,Operating table ,Examnation bad ,infant bed

Product Details

Features

Core

● Newly advanced A9 main board with Linux OS

● Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events review

Body

● 12.1 inches high-brightness TFT LED

● Support display 9~13 waveforms

● Support 7 channel ECG waveform display simultaneously

● Optional HDMI output


Printer

● Built-in high-speed 50mm thermal printer

Central System

● Wired or wireless connection


Alarm

● Three-level acousto-optic alarm

● Sensor-off alarm

● Paper out alarm

● Support alarm review

● Support alarm pause


 Linux OS


● Support operation with USB mouse and computer keyboard (option)

● Multi-display mode

● NIBP self-test mode

● Support medical history search by patient ID, name and mobile number

● 13 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection

● Drug calculation and titration table

● Multi-language display

● Online software upgrading by net/USB


Performance Specifications

 

Dimension and Weight

● Dimension: 310mm*290mm*150mm

● Weight: 3.4 kg (excluding accessories)


Power Supply

● Voltage: AC100~240V, 50/60HZ, Power≤60W


Display

● 12.1" color TFT LED resolution: 800*600 pixels


Battery

● Type: Rechargeable lithium battery 12V/2200mAh

● Charge Cycle: ≥500 times

● Working time: 2 hours


Recorder (Option)

● Method: Thermal printer

● Paper width: 50 mm (1.97 in)

● Printing speed: 12.5/ 25/ 50 mm/s

● Trace: Max. 3 tracks

● Recording way: Real-time Recording, Review Printing, Periodic Recording, Alarm Recording


Alarm

● Level: Low, medium and high

● Indication: Auditory and visual

● Alarm volume adjustable

● Alarm pause time: 1min, 2min

● Parameter alarm type: Latch/ Unlatch


Input Device

● Standard: Knob /Keypress

● Option: USB Mouse / USB Keyboard / Touch screen

 


System Output & Extensible Interface

● Ethernet Network: standard RJ45 socket * 1pc


● USB Port: 1pc


● Video Output: HDMI port (option) * 1pc


 

Operating Environment


● Temperature: 5 ~ 40  ℃


● Humidity: 15% ~ 90% (non-condensing)


● Atmosphere pressure: 86 KPa ~ 110 KPa

 

Transportation and Storage

● Temperature:   -20~50  ℃

● Humidity:    10%~90%   (non-condensing)

● Atmosphere pressure:   86 KPa ~ 110 KPa


Safety

● IEC60601- 1 Approved, CE marking according to MDD93/42/EEC

● With reference to RoHS Directive 2011/65/EU recasting



Trend & Reviewing

● Trend: 2160 hours

● ARR events: 128 groups of ARR events and associated waveform

● NIBP measurement reviewing: 2000 groups

● Waveform review: 2 hours

● Alarm event: 2000 groups of parameter alarms events and associated parameter


SpO2

● Measurement Range: 0 ~ 100 %

● Resolution: 1 %

● Accuracy:   ±2% (70% ~ 100%)


                       ±3 % (40% ~ 69%)


                     Unspecified (0 ~ 39%)


● Support Pitch tone and multi-level volume


● User-selectable waveform speed:6.25, 12.5, 25, 50 mm/s


● PI range (Option):0.075%-20%


 Pulse Rate


● Measuring and Alarm Range: 20~250bpm

● Accuracy: ±1% or ±1 bpm, whichever is greater

● Resolution: 1bpm

Respiration

● Method: Impedance between RA-LL, RA-LA

● Gain: ×0.25, ×0.50, ×1, ×2, ×4

● Respiration Rate: 0bpm, 6 ~ 150 BrPM

● Sweep speed:   6.25 mm/s, 12.5 mm/s, 25mm/s

● Resolution: 1 BrPM

Accuracy:±2BrPM or ±2% whichever is greater (7~ 150BrPM)


                 Unspecified (0%~ 6BrPM)


● Apnea Alarm: 10 ~ 40 s

 

Temperature

● Technique: Thermistor probe (2.25K)

● Channel: Dual-channel, provide T1; T2; ΔT

● Measuring and Alarm Range: 0.0  ℃~ 50  ℃ (32℉~ 122℉)

● Unit: Celsius (℃), Fahrenheit (  ℉)

● Resolution: 0.1℃or 1℉

● Accuracy: ±0.1℃(exclusive probe)

ECG


● Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V


● Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof


● Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto


● Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s


● ECG signal range:   ±5 mV p-p


● Accuracy: ±1bpm/ ±1%, whichever is greater


● Resolution: 1 bpm


● Leakage Current <10 μA


● Baseline Recovery:≤ 3s after defibrillation (Monitor mode) 


                                      ≤ 1s after defibrillation (Surgery mode)


● Bandwidth:  Surgery 1 ~ 20 Hz           Monitor 0.5 ~ 40 Hz        Diagnostic 0.05 ~ 130 Hz 


● Indication of Electrode Separation: Every electrode (exclusive of RL)


 Heart Rate


● Measure range: Adult:15~300bpm  Neo/Ped15~350bpm


● Resolution: 1 bpm


● Accuracy: ±1%


 

ST Measurement

● Range: -2.0 ~ +2.0 mV

● Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is - greater

● Other range: unspecified

● Resolution: 0.01mV



NIBP

● Method: Oscillometric                                                         -

● Measure mode: Manual, Auto, STAT

● Measure Interval in AUTO Mode 1~480 min

● STAT mode cycle time: Keep 5 minutes, at 5 seconds interval

● Measure and Alarm Range:


                       Adult:  SYS:       40 ~ 280 mmHg


                                   DIA:       10 ~ 220 mmHg


                                   MEAN:   20 ~ 240 mmHg


                 Pediatric:   SYS:       40 ~ 220 mmHg


                                   DIA:       10 ~ 160 mmHg

                                   MEAN:   20 ~ 170 mmHg


                 Neonate:   SYS:        30 ~ 135 mmHg


                                   DIA:       10 ~ 110 mmHg


                                   MEAN:   20 ~ 1 10 mmHg


● Static pressure accuracy: ±3mmHg


● Resolution: 1mmHg


● Accuracy: Maximum Mean error ±5mmHg            


                   Maximum Standard deviation ≤8mmHg


● Over pressure Protection: Dual protection via software & hardware


EtCO2 (Mainstream/ Sidestream) (Option)

● Measure method: Non-dispersive infrared (NDIR)

● Measure Range: 0 ~19.7% (0 ~ 150 mmHg)

                             0 ~ 20 kPa

● Resolution: 0.1 mmHg

● CO2 Accuracy:   0 ~ 40 mmHg, ±2 mmHg

                              41 ~ 70 mmHg, ±5% of reading

                              71 ~ 100 mmHg, ±8% of reading

                              101~ 150 mmHg, ±10% of reading

                              at 760 mmHg, ambient temperature of 25℃)

● Respiratory Rate: Range: 3 ~150 BrPM

                               Accuracy: ±1 bpm

 

EtCO2 (Micro-stream) (Option)

● Measure method: Non-dispersive infrared (NDIR)

● Measure Range: 0 ~19.7% (0 ~150 mmHg)

                             0 ~ 20 kPa

● Sample Rate: 50 mL/min ±10mL/min

● Resolution: 0.1 mmHg (0 ~ 50 mmHg)

                      0.25 mmHg (50 ~ 114 mmHg)

● CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg

                             41 ~ 70 mmHg, ±5% of reading

                             71 ~ 100 mmHg, ±8% of reading

                             101~ 150 mmHg, ±10% of reading

                              at 760 mmHg, ambient temperature of 35℃)

● Respiratory Rate: Range: 3 ~120 BrPM

                               Accuracy: ±1 bpm

 

IBP (Option)

● Max Channel: 2

● Measurement way: Thermal resistance way

● Press Sensor: Sensitivity 5 uV/V/mmHg, ±2%

                         Impedance 300 to 3000Ω

● Resolution: 1 mmHg

● Unit: mmKg, kPa, cmH2O

● Transducer sites:   Arterial Pressure (ART)

                                Pulmonary Arterial (PA)

                                Left Arterial (LAP)

                                Right Arterial (RAP)

                                Central Venous Pressure (CVP)

                                Intracranial Pressure (ICP)

                                P1/ P2

● Measuring and alarm range:   ART   0 ~ +350mmHg

                                                  PA       -10 ~ +120 mmHg

                    CVP/ RAP/ LAP/ ICP     -10 ~ +40 mmHg

                                             P1/ P2     -50 ~ +350mmHg

● Accuracy: Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer)

                               ±4mmHg or ±4%, whichever is greater (inclusive of transducer)

              Dynamic: ±4mmHg or ±4%, whichever is greater

 


Contact Supplier