Drill Pipe Magnetic Flux Leakage Detector MFL-308
USD $8 - $200 /Bag
Min.Order:1 Bag
Specifications: diameter Φ73 / Φ89 mm, length 9.6m or so
Detection speed: 6-20 m / min
Acceptance criteria: American Petroleum Institute API testing standards
The main MFI magnetic flux inspection method principle is that the workpiece is magnetized (close to saturation) to have a certain magnetic flux density to generate a leakage magnetic field at the discontinuity, and the mfl sensor sends the output signal to the operational amplifier.
Due to the magnetic saturation state, the workpiece has a relatively high magnetic field strength and magnetic field density, and the magnetic lines of force are not limited so that the surface of the workpiece has a large magnetic leakage, which is favorable for on-site detection.
The magnetic sensitive sensor scans along the surface of the magnetized ferromagnetic material, pick up the defect leakage magnetic field and forms a defect electrical signal to achieve the purpose of finding the defect position and parameters.
Magnetic pipeline inspection services technology is widely used in the detection of metal materials and the evaluation of related products due to its fast detection speed, high reliability and low surface cleanliness. Different from magnetic particle detection and detection, the signal in magnetic flux leakage detection is not displayed by magnetic powder, and it has no pollution to the environment: due to various sensitive components (such as Hall element and coil method), the detection result is directly output by electric signal, which is easy to connect with computer to realize digital Processing, so the detection results can be stored and reproduced, facilitating the analysis of the detection signal and the trend analysis of the detection results.
Drill Pipe Magnetic Flux Leakage Detector MFL-308 Performance
Drill pipe inspection method | Drill pipe straight ahead, test assembly |
fixed | |
Detection range | F60-F168drill pipe |
transport system speed | 6-20m/min;variable frequency range |
Testing methods | Automatic charging, Automatic testing, |
Automatic sorting | |
The sensitivity of hole detection | F1.6mmthrough hole(calibrated by 8 holes) |
Accuracy of section area | 2-4% |
measurement | |
Position resolution accuracy | 20mm |
Non-detection zone | £100mm(drill pipe body) |
False alarm rate | £0.5% |
Remaining magnetism after | £10GS |
demagnetization | |
The internal and external surface | 100% |
coverage | |
Equipment usage environment | Working temperature:40°-minus50 °; |
Working humidity:0-95%; |