Economical type 2-21th harmonic digital modbus RS485 3 phase 4 wire lcd smart ethernet kwh meter
Negotiable
Min.Order:1
Multifunction power monitoring device 3 phase electric power meter
Selling Solar Smart Electrical Power Meter KPM53-Z RS485 Interface Modbus-TCP
KPM51 Single-phase Smart Power Meter for Cost Center Analysis Needs
Selling Wifi Power Quality Analyzer Meter KPM75-K with High Quality
Multifunctioaln Power Meter KPM53E 3 Phase Digital Multimeter RS485 Communication
KPM 10 Economical type 2-21th harmonic digital modbus RS485 3 phase 4 wire lcd smart ethernet kwh meter
Application occasion
1.Measurement&Monitor energy parameter of distribution system.
2.Collect energy consumption data that cost center analysis needs.
3. Limit monitoring alarm(such as overvoltage, power consumption).
4.DC/Green building or DC.
Click Here Send Inquiry Now
KPM10 RS485 3 phase 4 wire lcd smart ethernet kwh meter | ||
Working Power Source | Operating Voltage | AC85~265V/DC80~300V |
Rated Power | <3VA | |
Input Voltage | Rated Voltage | 57.7/100V,220/380V, 380/660A (needs customization) |
Sill Value | 5V | |
Overload Capacity | 1.2 times rated voltage allowed,continuous work; 2 times the rated voltage allowed 1 second | |
Power Consumption | <0.5VA/phase(rated) | |
Measurement Range | 5~260VAC, | |
Frequency Range | 45~65Hz | |
Input Current | Rated Current | Default 5A,Input range 1-6A;Optional 1A,Input range 1-1.2A |
Sill Value | 5A Configuration,5mA;1A Configuration,0.8mA | |
Overload Capacity | 1.2 times rated current allowed,continuous work; 20 times the rated current allowed 1 second | |
Power Consumption | <0.75VA/phase(Rated current 5A);<0.25VA/phase(Rated current 1A) | |
Frequency Range | 45~65Hz | |
Input/Output | Switch Value Input | 2-way passive main line contact DI input, internal supply DC24V power source |
Relay Output | 2-way DO output, Contact capacity 250VAC/5A,30VDC/5A | |
Power Quality Monitor | Harmonic Measurement | Voltage/current2~21th harmonic distortion rate, total harmonic distortion rate. |
Harmonic Distortion Rate | Phase voltage,line voltage | |
Imbalance Rate | Voltage. current | |
Measurement Accuracy | Voltage | ±0.2%(0.01V) |
Current | ±0.2%(0.01A) | |
Active Power | ±0.5%(0.1W) | |
Reactive Power | ±2.0%(0.1kvar) | |
Active Energy | ±0.5%(0.1kWh) | |
Reactive Energy | ±2.0%(0.1kvarh) | |
Power Factor | ±0.5%(0.001) | |
Frequency | ±0.02Hz(0.01Hz) | |
Temperature | ±1℃(1℃) | |
Communication | Communication Interface | RS485,Photoelectric isolation interface |
Communication Protocol | Modbus-RTU,1200~38400bps | |
Electrical Insulation | Power Frequency Withstand Voltage | AC2kV/min~1mA Input-output-power source (GB/T 13729) |
Insulation Resistance | >50MΩ (GB/T 13729) | |
Impact Voltage | 5kV(Peak)1.2/50us (GB/T 13729) | |
Working Environment | Operating Temperature | -25℃ ~ +70℃ |
Relative Humidity | 5%~95% No condensation | |
Storage Temperature | -30℃ ~ +75℃ | |
Altitude | No more than 4000m |