FRP GRP SMC Fire Fighting Sectional Water Storage Tank
FRP GRP SMC Fire Fighting Sectional Water Storage Tank
FRP GRP SMC Fire Fighting Sectional Water Storage Tank
FRP GRP SMC Fire Fighting Sectional Water Storage Tank
FRP GRP SMC Fire Fighting Sectional Water Storage Tank

FRP GRP SMC Fire Fighting Sectional Water Storage Tank

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Hengshui Aoliande Trading Co., Ltd.

Business Type: Trading Company
Main Products: , , ,

Product Details

Product Description

 FRP GRP SMC Fire Fighting Sectional Water Storage Tank

 

FRP GRP SMC tank Fiberglass Water Storage Tank Water Tanks Suppliers

SMC fiberglass water tank is also called SMC storage tank, FRP/GRP water tank, SMC panel tanks. It is a new type of tank. It is made of high qualified SMC panels. Sheet molding compound (SMC) is a kind of fiberglass reinforced plastic, which is a mixture of unsaturated polyester resin with impregnating augmentation material, filling material and glass fiber. SMC water tank is nontoxic, durable, lightweight, corrosion resistant and good-looking. Meanwhile, it's easy to maintain and long-life. It is widely used in water storage in residential buildings, schools, hotel. SMC water tanks are used both for domestic water as well as medicine and health where needs good water supply quality.

 

 FRP GRP SMC Fire Fighting Sectional Water Storage Tank

 

FRP GRP SMC Fiberglass Water Storage Tank Water Tanks / Sectional Water Tank Specifications


1. SMC moulded singal board specifications(If need other specifications we can chatting)
1000x1000mm ,1000x 500mm ,500x 500mm
2. Thickness:5mm, 8mm, 10mm ,12mm, 14mm,,16mm ,The thinkness is 5mm signal board is used for water tank cover plate
3. SMC moulded water tank is measure up GB5749-85
4. Capacity: 0.125m3 ~ 5000m3

 FRP GRP SMC Fire Fighting Sectional Water Storage Tank

SMC moulded signal baord specifications:

Tensile strength Mpa ≥70MPa
Bending strength  ≥100 Mpa
Barcol hardness ≥60  
Water absorption  ≤ 1.0%
Fiber glass content ≥25% 
Flexural Modulus of Elasticity ≥ 5900MPa

 

Installation Instructions of FRP GRP SMC Fiberglass Water Storage Tank Water Tanks

1 Based on the first plane leveling cement, on the same plane so that the error should not exceed ± 0.5cm.
Welding channel: channel according to the size of the tank welding good match its size and the tank floor size, channel steel welding complete, the diagonal measurements, error of ± 0.5cm, and all welds to connect uniform row seam line.
2 Install the end state: water tank according to the board printed number and description of the arrangement, the connection of the tank bottom, while between two boards add sealing tape, bolted ¢ 10's. Securely sealed bottom plate, bolt afterburner afterburner to a uniform, one-time can not be too much force, otherwise due to uneven force caused by the split plate phenomenon.
3 Is connected with a fixed angle iron and channel steel base plate, so that the tank housing more firmly fixed on the basis of the channel.
4 Install states: water tank according to the board printed number and description to identify the layers BOND NO tank state body, and previously separate state body assembled with bolts.
5 Install stretch: Stretch inner tank according to the size, number and find internal reinforcement length. Measuring stretch of wire reinforcement plate fastening parts, Indian painting, drilling, on to the wire, tighten to make a flat stretch in balance with the tank housing. If there is a large error between the casing and reinforcement, can be adjusted by adjusting the size of the error bolt tightness, until the error is adjusted to a minimum so far.
6 Install the cover: the final installation of the tank top cover, and even fastening bolts can not force too large or too small. After all the fasteners tank adjusted, according to the drawing hole location, a good all pipes, having a good valve flange for docking.
7 Tanks fully installed, unified inspection, adjustment, test the water does not leak in compliance.

 FRP GRP SMC Fire Fighting Sectional Water Storage TankFRP GRP SMC Fire Fighting Sectional Water Storage Tank

How to correctly use fiberglass tanks?

 

1. Fiberglass tanks for the storage of drinking water at room temperature and the design and manufacture, please do not store hot water and other liquids (chemicals, oil, etc.)
2. On-site construction: pre-construction, install the stay requested by the foundation. Providing power and construction inspection seal with water.
3. To avoid water tank next to the fire: When welding operations, to take protective measures, not to splash the water tank panels Mars.
4. To prevent contaminants from flowing into the tank from the outside: for the convenience and safety of maintenance and inspection, the tank must leave some space around.
5. The molded fiberglass boards do not touch on the corners, do not beat something with hard tools.
6. In order to prevent expansion of the pipe, shrinkage, partial load and shock, glass steel water tank, outlet pipe must be of rubber around the streets (expansion joints), to take over the additional weight should be supported, not acting on the tank.

Welcoming your visit and customized design inquiry. We are professional Group Factory. We have completely service team and technical support team. Overseas help are available too. Any request freely inform me.

 

FRP GRP SMC Fire Fighting Sectional Water Storage TankFRP GRP SMC Fire Fighting Sectional Water Storage TankFRP GRP SMC Fire Fighting Sectional Water Storage Tank

Production line

FRP GRP SMC Fire Fighting Sectional Water Storage Tank

Company Information

Hengshui Aoliande Trade Co., Ltd. is professional company which to market & sell FRP Pipe, FRP storage tank, FRP molded products, FRP pultrused products and FRP production machines, through the continuous development and introduction of professionality and technology, the company rely on advanced technology, exquisite craftsmanship, reliable quality and perfect service, passed ISO9001, ISO14001, OHSAS18001 management system certification, now we have 50+ staff, annual sales of glass fiber reinforced plastic series products achieved 5,000,000 USD, products have been sold to all over the world, USA, Brazil, Japan, Germany, India, Malaysia, Egypt etc, and won the support and trust from new & old customers.FRP GRP SMC Fire Fighting Sectional Water Storage TankOur customers and certificates

FRP GRP SMC Fire Fighting Sectional Water Storage TankFRP GRP SMC Fire Fighting Sectional Water Storage Tank

FAQ

 

1. Q: Are you Trading Company or Manufacturing Factory?

A: We are both manufacturer and trading company. We have our own factory for almost 10 years, and we have better service of overseas customers. Welcome to send your inquiry!

 

2. Q: How about the Delivery time?

A: Normally, 10-15 days to finish the order for a 20ft container. Welcome to ask for the detailed delivery time according to your order quantity!

 

3. Q: How can you guarantee the product quality?

A: We have the quality control system ISO9001:2015, and it's been followed strictly. We also have the professional QC team, and each our package worker will be in charge of the final inspection according to the QC instruction before packing.

 

4. Q: What is about the payment terms.

A: Basically, the payment terms are paypal, T/T, L/C at sight. Western Union, Alipay.

 

5. Q: Can you do OEM for me?

A: We accept all OEM orders, just contact us and give me your design,we will offer you a reasonable price ASAP.

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Environment > Water Treatment
Categories
Hi~