Extremely wet 90%~100% RH you need to extract 10 liters for every 50 sq.m, and add 4 liters for every additional 50 sq.m
Wet 80%~90% RH you need to extract 8 liters for every 50 sq.m, and add 3.5 liters for every additional 50 sq.m
Very Damp 70%~80% RH you need to extract 6 liters for every 50 sq.m, and add 3 liters for every additional 50 sq.m
Dampness 60%~70% RH you need extract 5 liters for every 50 sq.m, and add 2.5 liters for every additional 50 sq.m
How do I know the right CMH and ACH that needed for the area?
ACH is that the air exchange times per hour needed for the area,here under is the recommended value that for different conditions.
Extremely wet 90%~100% RH ACH=6
Wet 80%~90% RH ACH=5
Very Damp 70%~80% RH ACH=4
Dampness 60%~70% RH ACH=3
CMH is a parameter to represent the circulating air flow which means cube meter per hour that dehumidifier working in the area, it equals to cube meters of area by ACH needed. For example, 50 sq.m area with floor height 3 meters, in 90%~100% RH condition, it needs 50x3x6=900 CMH.
What’s the application of a TOJJE commercial dehumidifier?
In an idea for coverage of commercial dehumidifier is around 20 sq.m area up to 150 sq.m area with standard floor height 2.6m to 3.5m, so it widely used in home, office, warehouse, electricity room, basement, plant growing workshop and other areas need to be dehumidified.