Yokogawa Analog I/O Module AAI835-S50 With Best Price In Stock
Negotiable /Piece
Min.Order:1 Piece
HONGKONG XIEYUAN TECH CO., LIMITED
Yokogawa Analog I/O Module AAI135-S00 With Best Price In Stock
Yokogawa Analog I/O Module AAI135-S03 With Best Price In Stock
Yokogawa Analog I/O Module AAI135-SE0 With Best Price In Stock
Yokogawa Analog I/O Module AAI135-SE3 With Best Price In Stock
Yokogawa Analog I/O Module AAI135-H00 With Best Price In Stock
Yokogawa Analog I/O Module AAI135-H03 With Best Price In Stock
Yokogawa Analog I/O Module AAI835-S50 With Best Price In Stock
Yokogawa AAI835 Analog input output Module is a 4 channels isolated Analog I/O Module for 4 to 20mA Current Input and output signals of centum VP DCS system.
Yokogawa AAI835 Analog input output Module is a 4 channels isolated Analog I/O Module can be installed on Field Control Unit or ESB bus node unit for 4 to 20mA Current Input signals from field instrument or valve positioners, also output signals from Field Control Unit to field control devices such as valve positioners, mechanic equipments and etc. HART communication function is optional. Three types of connection selectable as Pressure clamp terminal, MIL connector cable or dedicated cable KS1, Dual-redundant communication is available by installing two communication modules on the same unit. It connects to terminal board AEA4D with signal cable KS1 type.
2. Standard Specification
Main Characters | Description |
Number of input channels | 4-channel input/4-channel output, isolated channels |
Input signal | 4 to 20 mA |
Allowable input current | 25 mA |
Withstanding voltage | Between input/output and system: 500 V AC, for 1 minute Between input/output channels: 500 V AC, for 1 minute |
Data update period | 10 ms |
Transmitter power supply | 15.0 V or higher (at 20 mA), 29.3 V or less (at 0 mA) |
Setting of 2-wire or 4-wire transmitter | For each channel by setting pin |
Drift due to ambient temperature change | ±16 μA per 10 ˚C |
Maximum current consumption | 360 mA (5 V DC), 450 mA (24 V DC) |
External connection | Pressure clamp terminal, MIL connector cable, dedicated cable (KS1) |
HART communication | Available |
3. Model Selection of AAI135 Analog Input Module
Model | Suffix Codes | Description | |||
AAI835 | Analog I/O Module (4 to 20 mA, 4-channel input/4-channel output, Isolated channels) | ||||
-S | Standard type | ||||
-H | With digital communication (HART protocol) | ||||
5 | Standard type with no explosion protection | ||||
E | Standard type with explosion protection | ||||
0 | Basic type | ||||
3 | With ISA Standard G3 option and temperature (-20 to 70 °C) option | ||||
Option Code | /B3A00 | With KS Cable Interface Adapter [Model: ATB3A-00] | |||
/K4A00 | With KS Cable Interface Adapter [Model: ATK4A-00] | ||||
/13S00 | With Pressure Clamp Terminal Block for Isolated Analog [Model: ATI3S-00] | ||||
/13S10 | With Pressure Clamp Terminal Block for Isolated Analog (surge absorber) [Model: ATI3S-10] | ||||
/13D00 | With Dual Pressure Clamp Terminal Block for Isolated Analog [Model: ATI3D-00] | ||||
/13D10 | With Dual Pressure Clamp Terminal Block for Isolated Analog (surge absorber) [Model: ATI3D-10] | ||||
/CCC01 | With Connector Cover for MIL Cable [Model: ACCC01] |
4. Typical Order Codes
Typical order codes | Remarks |
AAI835-S50 | Standard type |
AAI835-S53 | Standard type with ISA G3 and wide temperature (-20 to 70 °C) |
AAI835-H50 | Hart type |
AAI835-H53 | Hart type with ISA G3 and wide temperature (-20 to 70 °C) |
AAI835-S50/K4A00 | Standard type with ATK4A terminal block |
AAI835-S53/K4A00 | Standard type with ISA G3 and wide temperature (-20 to 70 °C) with terminal block |
AAI835-H50/K4A00 | Hart type with ATK4A terminal block |
AAI835-H53/K4A00 | Hart type with ISA G3 and wied temperature (-20 to 70 °C) with terminal block |
AAI835-H00/B3A00 | AAI835-S00/B3A00 |
AAI835-H00/K4A00 | AAI835-S00/K4A00 |
AAI835-H00/13S00 | AAI835-S00/13S00 |
AAI835-H00/13S10 | AAI835-S00/13S10 |
AAI835-H00/13D00 | AAI835-S00/13D00 |
AAI835-H00/13D10 | AAI835-S00/13D10 |
AAI835-H00/CCC01 | AAI835-S00/CCC01 |
AAI835-H03/B3A00 | AAI835-S03/B3A00 |
AAI835-H03/K4A00 | AAI835-S03/K4A00 |
AAI835-H03/13S00 | AAI835-S03/13S00 |
AAI835-H03/13S10 | AAI835-S03/13S10 |
AAI835-H03/13D00 | AAI835-S03/13D00 |
AAI835-H03/13D10 | AAI835-S03/13D10 |
AAI835-H03/CCC01 | AAI835-S03/CCC01 |
AAI835-HE0/B3A00 | AAI835-SE0/B3A00 |
AAI835-HE0/K4A00 | AAI835-SE0/K4A00 |
AAI835-HE0/13S00 | AAI835-SE0/13S00 |
AAI835-HE0/13S10 | AAI835-SE0/13S10 |
AAI835-HE0/13D00 | AAI835-SE0/13D00 |
AAI835-HE0/13D10 | AAI835-SE0/13D10 |
AAI835-HE0/CCC01 | AAI835-SE0/CCC01 |
AAI835-HE3/B3A00 | AAI835-SE3/B3A00 |
AAI835-HE3/K4A00 | AAI835-SE3/K4A00 |
AAI835-HE3/13S00 | AAI835-SE3/13S00 |
AAI835-HE3/13S10 | AAI835-SE3/13S10 |
AAI835-HE3/13D00 | AAI835-SE3/13D00 |
AAI835-HE3/13D10 | AAI835-SE3/13D10 |
AAI835-HE3/CCC01 | AAI835-SE3/CCC01 |
5.Dual-redundant System Configuration
Any inquiry,Please feel free to contact: | ||
Windy Wang | ||
windy@hkxytech.com | ||
HONGKONG XIEYUAN TECH CO., LIMITED | ||
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China | ||
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 |