Simulate Environment Adhesive Tape Xenon Lamp Aging Test Equipment
Negotiable
Min.Order:1
Lab Large Plastic Xenon Lamp Aging Test Equipment For Adhesive
Climatic Constant Temperature Humidity Chamber Programmable Constant Temperature And Humidity Box
Large Xenon Lamp Accelerated Weathering Environment Aging Test Equipment Machine
Stability Laboratory Xenon Lamp Aging Test Equipment Machine Chamber
Simulate Environment Large Xenon Lamp Aging Test Chamber Machine Chambers
Inner size(cm):D×W×H | 50×60×50 | ||
Temperature range | RT+10℃~80℃ | ||
Performance specification | Humidity range | 30~98%R.H(adjustable) | |
Rain falling time | 0~9999min (adjustable) | ||
Rain falling period | 1~240minutes,interval(break),adjustable | ||
Spectral wavelength | 300nm~400nm(0.55w/m²) | ||
Light source | Full spectrum xenon lamp | ||
Xenon lamp total power | 1KW(air cooling), 6KW(air cooling),(lifetime:1200hours) | ||
Temperature and humidity control system | Time Controller | Imported programmable time computer integrated controller | |
Accuracy range | Setting accuracy: temperature ±0.1℃,humidity±1%R.H, Indicate accuracy:temperature,±0.1℃,humidity,±1%R.H | ||
Temperature Humidity Sensor | PTR Platinum Resistance,PT100Ω/MV | ||
Heating system | autonomous system,nichrome electric heating heater | ||
Humidification System | isolated type, SUS steel surface evaporative humidifier. | ||
Blackboard temperature | thermometal blackboard thermometer 55℃~75℃ | ||
Water supply system | Automatic control for humidification system, recycling water for xenon lamp cooling. | ||
Temperature controller | Imported microcomputer temperature humidity integration controller | ||
Cyclic system | low noise,air-condition type motor, multiple-pin Centrifugal rotor | ||
Material | Outside chamber material | SUS304 stainless steel. | |
Inner chamber material | SUS304 stainless steel plate | ||
Sample shelf material | SUS304 stainless steel plate | ||
Doorframe heat insulation | good heat and cold resistance, aging silicone rubber door and sealing strips | ||
Standard configuration | non-browning glass observing window 1pcs,rack shelf 1 set, xenon lamp 1pcs | ||
Safeguard protection | leakage,short circuit,over temperature,short of water,motor overheating, over-current protection, Backup data for power fail | ||
Voltage power | AC380V±10% 50±0.5Hz 3 phase 5 lines | ||
Using temperature | 5℃~+30℃≤85%R.H | ||
Testing standards | ASTM G 155-04a, ASTM G 151, SAE J2527,GB/T2423.24-1995 GB/T16422.2 GB9344 GB/T1865-97 |