Improving efficiency power factor correction control increases power factor load harmonic distortion filter
Improving efficiency power factor correction control increases power factor load harmonic distortion filter
Improving efficiency power factor correction control increases power factor load harmonic distortion filter
Improving efficiency power factor correction control increases power factor load harmonic distortion filter
Improving efficiency power factor correction control increases power factor load harmonic distortion filter

Improving efficiency power factor correction control increases power factor load harmonic distortion filter

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Strong Power Electric Co.,Ltd.

Business Type: Distributor/Wholesaler
Main Products: , , ,

Product Details

Product Description

 

Improving efficiency power factor correction control increases power factor load harmonic distortion filter

 

 

Improving efficiency power factor correction control increases power factor load harmonic distortion filter

 

Improving efficiency power factor correction control increases power factor load harmonic distortion filter 

Description

Power factor controller is one of the most important components of the power factor correction equipment. As such, it plays a key role in the control and monitoring of the power factor and the system power quality. Can offers power factor control, measurements, monitoring and communication etc function.

 

Power Factor Control Relays automatically detects the amount of kVAR needed to meet a target power factor and switches in the proper amount. The auto-commissioning feature identifies the current and kVAR requirements of normal loads and avoids over-compensation at light loads. minimizes the wear of the power factor correction system and reduces disturbances on the electrical system.

 

Application Site

Power factor controller range of controllers can be used to control industrial and commercial networks. Application examples include power factor control in buildings,electricity, petroleum, steel, coal, chemical industry, ports, rural and urban power grids, mining steel industry, pulp and paper, cement, plastics, printing, smelters, hospitals, automotive industry and food industries. or fixed power factor corrections individual (eg. motors, transformers, lighting), group fixed power factor correction (several equipmentsconnected in a group), harmonics trap applications (eg. UPS, VFDs, converters, etc.).

 

Advantages

Technical Parameters

High voltage control system

Model

ZBWKG-5000

ZBWKG-3500B

ZBWKG-3500

ZBWKG-3000

ZBWKG-2000

ZBWKG-1000

Line NO YES NO YES NO YES
Concentrated NO NO YES YES YES NO
Substation YES NO NO NO NO NO
485 YES YES YES YES YES NO
232 YES YES YES YES YES NO
Wireless Communication NO  YES NO NO NO NO
GPRS NO YES NO YES NO NO
Data Storage YES YES NO YES NO NO
Wall-mounted NO YES NO YES NO NO
Embedded YES NO YES YES YES YES
Background Software YES YES YES YES NO NO
Voltage  AC/DC85~250 AC220 AC/DC85~250  AC/DC85~250 AC220 AC220
Sampling Voltage  0-150 100/220 0-150 0-150 100/220 220
Sampling Current  0~5 0~5 0~5 0~5 0~5 0~5
Frequency  50±5% 50±5% 50±5% 50/60 50±5% 50±5%
Responding Speed 1 1 1 1 1 1
Shape 265*200*220 230*125*80 270*165*75 270*140*80 144*144*105 168*108*118
Perforation 247*124 220*65 242*152 258*65 138*138 162*102

 

 

Low voltage control system

Model

ZBWN-3500

ZBWKF-18C/12C

ZBWKE

ZBWKD

ZBWKC

ZBWKA

Line

N Y Y Y N Y

Concentrated

Y Y Y Y Y N

Substation

N N N N N N

485

Y Y Y Y Y N

232

Y Y Y Y Y N

Wireless Communication

N Y N N N N

GPRS

N Y N Y N N
Data Storage N Y N Y N N
Wall-Mounted N N N N N N
Embedded Y  Y Y Y Y Y
Co-Complement Y N N N Y Y

Hybrid Compensation

N Y Y Y N N

Digital Display

N N N N N Y

LCD

Y Y Y Y Y N

Background Software

Y Y Y Y N N

Voltage

220±20% 220±20% 220±20% 220±20% 380±20% 380±20%
Sampling Voltage 380 220 220 220 380 380
Sampling Vurrent 0~5 0~5 0~5 0~5 0~5 0~5

Frequency

50±5% 50±5% 50±5% 50/60 50±5% 50/60

Responding Speed

20ms 1s 20ms 20ms 20ms 1s

Shape

270*165*75 144*144*105 144*144*105 144*144*105 144*144*105 168*108*118
Perforation 242*152 138*138 138*138 138*138 138*138 162*102

 

 

Related products

Improving efficiency power factor correction control increases power factor load harmonic distortion filter

Company Information

 

Improving efficiency power factor correction control increases power factor load harmonic distortion filter

Improving efficiency power factor correction control increases power factor load harmonic distortion filter

Improving efficiency power factor correction control increases power factor load harmonic distortion filter

Improving efficiency power factor correction control increases power factor load harmonic distortion filter

Packaging & Shipping

 

Improving efficiency power factor correction control increases power factor load harmonic distortion filter