Svg three phase kvar modular power factor correction equipment price
Description
The static var generator,based on voltage type inverter principle,uses IGBT to control the value and phase of AC voltage of inverter, so as to serve the purpose of reactive and harmonic compensation. SVG can realize fast compensation for reactive load, and achieve very high compensation precision.
SVG is currently the best solution in reactive power control filed. SVG is faster (within 10ms), its compensation precision is high (power factor over 0.99), the compensation method is flexible (SVG can compensate both inductive reactive power and capacitive reactive power), and SVG also has the function of active filtration of harmonic current.
Application Site
Advantages
1. Compensate reactive power of system to improve the power factor.
2. Reduce line losses; improve the abolity of the transmission line.
3. With the dynamic compensation of harmonics, to improve power quality.
4. Inhibition of the fluctuation and flicker of voltage.
5. Maintain the receiving end voltage; strengthen the stability of system voltage.
6. Inhibition of the unbalance of three-phase.
7. Efficiency: up to 97.5%.
8. Regular input voltage: 380V±20% Special input voltage such as 480V, 690V and etc can be customized.
9. Up to 8 modules in parallel operation max.
Technical Parameters
Rated voltage | 400V,660v,750v,1250v |
Stand-alone device capacity | 50A-500A |
Instantaneous response speed | <0.1ms |
Full response speed | <10ms |
Voltage flicker suppression ratio | 5:1 |
Current distortion rate after compensation | THDI<4%, can filter out the 30th harmonic |
Voltage distortion rate after compensation | THDV<5% |
Power factor | >0.99, users can set |
Correct three-phase unbalance | Unbalance degree <3% |
Design service life | >20 years |
Efficiency | >99% |
Installation and heat dissipation method | Indoor installation and air cooling |
Overload capacity | 2*Irms peak current overload capability |
Protective function | It is the same as overvoltage, undervoltage, phase loss, short circuit protection, device overcurrent, overheat protection, IGBT protection, etc. |
Electromagnetic Compatibility | Meet the requirements of EU standard EN50121-5:2000 |
Grid frequency | 50/60 Hz |
Noise level | <75dB |
Ambient temperature | -10℃~40℃ |
Protection level | IP31 (please contact manufacturer for higher protection level) |
Humidity | <90% (All circuit boards are coated with three anti-paints) |