11kv ht outdoor vacuum circuit breaker auto recloser manufacturers
Negotiable
Min.Order:1
China sichuan outdoor high voltage 15kv ac vacuum circuit breaker
China 33kv outdoor high voltage vacuum circuit breaker price
Smart grid 35kv 2500a three phase 50hz ac vacuum circuit breaker recloser
7.2 kV to 36 kV 240v ac motor for 3ah3 vaccum circuit breaker
Outdoor ac high voltage vacuum circuit breaker 10kv 11kv 24kv vcb
Three-phase ac 50hz rated voltage 10kv high voltage outdoor vacuum circuit breaker autorecloser
11kv ht outdoor vacuum circuit breaker auto recloser manufacturers
Description
Vacuum circuit breaker is a special type of electrical circuit breaker that is designed to rapidly open and close. Unlike circuit breakers, which are designed to “trip” and stay in the open state, it can rapidly transition states from closed, to open and back. These devices aim to stop network faults from causing long outages, by quickly restoring power.
Vacuum circuit breaker is the automatic configuration of a circuit breaker to close after opening due to a protection operation. It is used in both Medium Voltage distribution and High Voltage Transmission, although in slightly different ways. Distribution VCB uses standalone autoreclosers, such as the Recloser product, which has an integrated control system, an HV Reclosing Circuit Breaker and a Remote SCADA FTU.
Application
Advantages
1.Vacuum circuit breaker can greatly improve the reliability of overhead distribution networks by mitigating the impact of momentary faults.
2.Vacuum circuit breaker reduce outages from these transient sources, increasing uptime of power supply.
3.Utilities that deploy reclosers for their overhead distribution networks experience significant reliability improvements.
4.Longer product service life and more resilience to bad weather.
Technical Parameters
serial number | Project | Unit | Value |
1 | Rated Maximum Voltage | kV | 15.5-38 |
2 | Rated frequency | Hz | 50-60 |
3 | Rated Continuous Current | A | 800 |
4 | Fault Make Capacity (RMS) | kA | 12.5/16 |
5 | Fault Make Capacity Peak | kA | 31.5/40 |
6 | Fault Break Capacity | kA | 12.5/16 |
7 | Fault Break Capacity Operations | 70-140 | |
8 | Short Time Current Withstand | secs | 16kA/3 |
9 | Mainly Active Breaking Capacity | A | 800 |
10 | Cable Charging Current | A | 25/40 |
11 | Impulse Withstand Phase to Earth & Phase to Phase | kV | 110-200 |
12 | Impulse Across the Interrupter | kV | 110-170 |
13 | Power Frequency Across the Interrupter | kV | 50-70 |
14 | Ambient Temperature | °C | -40°C to +55°C |
15 | Humidity | 0-100% | |
16 | Altitude | m | 3000 |
17 | Weight | kg | 100-150 |
Related products