33kv automatic outdoor circuit breaker intelligent power reclosing switch
Negotiable
Min.Order:1
Power transmission system control and protection solutions 25ka 35kv outdoor vacuum circuit breaker
15kv 800a solid insulated pole mount outdoor automatic recloser vacuum circuit breaker
MV smart distribution recloser single phase 11kv 300a controlled recloser vacuum circuit breaker
New type high voltage auto vacuum recloser smart remote control earth leakage switch
New technology high voltage 33kv outdoor automatic circuit breaker
Description
Vacuum circuit breaker is a special type of electrical circuit breaker that is designed to rapidly open and close. Unlike circuit breakers, which are designed to “trip” and stay in the open state, it can rapidly transition states from closed, to open and back. These devices aim to stop network faults from causing long outages, by quickly restoring power.
Vacuum circuit breaker is the automatic configuration of a circuit breaker to close after opening due to a protection operation. It is used in both Medium Voltage distribution and High Voltage Transmission, although in slightly different ways. Distribution VCB uses standalone autoreclosers, such as the Recloser product, which has an integrated control system, an HV Reclosing Circuit Breaker and a Remote SCADA FTU.
Application
Advantages
1.Vacuum circuit breaker can greatly improve the reliability of overhead distribution networks by mitigating the impact of momentary faults.
2.Vacuum circuit breaker reduce outages from these transient sources, increasing uptime of power supply.
3.Utilities that deploy reclosers for their overhead distribution networks experience significant reliability improvements.
4.Longer product service life and more resilience to bad weather.
Technical Parameters
serial number | Project | Unit | Value |
1 | Rated Maximum Voltage | kV | 15.5-38 |
2 | Rated frequency | Hz | 50-60 |
3 | Rated Continuous Current | A | 800 |
4 | Fault Make Capacity (RMS) | kA | 12.5/16 |
5 | Fault Make Capacity Peak | kA | 31.5/40 |
6 | Fault Break Capacity | kA | 12.5/16 |
7 | Fault Break Capacity Operations | 70-140 | |
8 | Short Time Current Withstand | secs | 16kA/3 |
9 | Mainly Active Breaking Capacity | A | 800 |
10 | Cable Charging Current | A | 25/40 |
11 | Impulse Withstand Phase to Earth & Phase to Phase | kV | 110-200 |
12 | Impulse Across the Interrupter | kV | 110-170 |
13 | Power Frequency Across the Interrupter | kV | 50-70 |
14 | Ambient Temperature | °C | -40°C to +55°C |
15 | Humidity | 0-100% | |
16 | Altitude | m | 3000 |
17 | Weight | kg | 100-150 |