China manufacture smart circuit breaker outdoor 27kv vcb electric circuit
Negotiable
Min.Order:1
Medium voltage switchgear 3 phases encapsulated automatic recloser control unit
High voltage substation and electric pole 22kv 50/60hz 3 phase auto recloser smart controller
Outdoor 3 phases automatic recloser medium voltage ac vacuum smart circuit breaker controller
Automatic vacuum circuit breaker recloser switch unit recloser controller line protection relay
11kv 27kv 38kv pole mounted vacuum auto recloser controller unit ftu
Vacuum circuit breaker recloser controller protective relay senses faults and clear the fault
China manufacture smart circuit breaker outdoor 27kv vcb electric circuit
Description
Vacuum circuit breaker is a special type of electrical circuit breaker that is designed to rapidly open and close. Unlike circuit breakers, which are designed to “trip” and stay in the open state, it can rapidly transition states from closed, to open and back. These devices aim to stop network faults from causing long outages, by quickly restoring power.
Vacuum circuit breaker is the automatic configuration of a circuit breaker to close after opening due to a protection operation. It is used in both Medium Voltage distribution and High Voltage Transmission, although in slightly different ways. Distribution VCB uses standalone autoreclosers, such as the Recloser product, which has an integrated control system, an HV Reclosing Circuit Breaker and a Remote SCADA FTU.
Application
Advantages
1.Vacuum circuit breaker can greatly improve the reliability of overhead distribution networks by mitigating the impact of momentary faults.
2.Vacuum circuit breaker reduce outages from these transient sources, increasing uptime of power supply.
3.Utilities that deploy reclosers for their overhead distribution networks experience significant reliability improvements.
4.Longer product service life and more resilience to bad weather.
Technical Parameters
serial number | Project | Unit | Value |
1 | Rated Maximum Voltage | kV | 15.5-38 |
2 | Rated frequency | Hz | 50-60 |
3 | Rated Continuous Current | A | 800 |
4 | Fault Make Capacity (RMS) | kA | 12.5/16 |
5 | Fault Make Capacity Peak | kA | 31.5/40 |
6 | Fault Break Capacity | kA | 12.5/16 |
7 | Fault Break Capacity Operations | 70-140 | |
8 | Short Time Current Withstand | secs | 16kA/3 |
9 | Mainly Active Breaking Capacity | A | 800 |
10 | Cable Charging Current | A | 25/40 |
11 | Impulse Withstand Phase to Earth & Phase to Phase | kV | 110-200 |
12 | Impulse Across the Interrupter | kV | 110-170 |
13 | Power Frequency Across the Interrupter | kV | 50-70 |
14 | Ambient Temperature | °C | -40°C to +55°C |
15 | Humidity | 0-100% | |
16 | Altitude | m | 3000 |
17 | Weight | kg | 100-150 |