Portable HVDC Generator,DC voltage Withstand Tester,Leakage Current Test of HV Electrical Equipments
Negotiable
Min.Order:1
Anti-fatigue Anti-vibration Maintenance Free Low Noise Lab Oil Liquids Vibration Test Instrument
GC Transformer Oil Testing/Transformer Oil Dissolved Gas Analyzer
New condition TP-2100 Automatic oil water content Karl Fischer Coulometric titrator
VST-2000 ASTMD445 Automatic Digital LCD Kinematic Viscosity Tester/Portable Dynamic Viscometer
Portable HVDC Generator,DC voltage Withstand Tester,Leakage Current Test of HV Electrical Equipments
Application:
HIPOT tester is applied to test the insulation ability of electric power equipment and insulation materials at power
frequency high voltage. The insulation test result of the tester is go or not go. Also the HIPOT tester is a universal
power source in HV test. The maximum output voltage and capacity could be customized according the requirements
of custom.The tester is consists of single HV transformer and main control box. There are three kinds of HV transformer according to the insulation materials of the HV transformer. They are dry HV transformer,oil HV
transformer and SF6 gas HV transformer. For the dry HV transformer the insulation material is epoxy resin.
For oil HV transformer the insulation material is insulation oil. For SF6 HV transformer the insulation material
is SF6 gas.The dry HV transformer has a smaller size and less weight than oil HV transformer. But the
maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are
voltage output regulation, protection in emergency and voltage/current value indication.
Technical parameter:
1) Power supply:
AC 220V 50Hz/60Hz for transformers which the capacity less than 10kva
AC 380V 50Hz/60Hz for transformers which the capacity more than 10kva
2) HV transformer mode: single phase
3) Maximum output voltage: 50kv/100kv/150kv/200kv/250kv optional
4) Output capacity: 3kva/5kva/10kva/20kva/30kva/50kva/100kva/150kva/200kva optional
5) Voltage read mode: analog or digital, direct HV voltage reading form voltmeter
6) Current read mode: analog or digital, direct LV circuit current reading from amp meter
7) Protection mode: LV circuit over current protection
8) Voltage adjust mode: manual regulation
9) Rated frequency: 50Hz/60Hz
10) Automatic zero position lock unit to avoid wrong operation in HV output
11) Work temperature: 0~50degree
12) Work humidity: <80%
Model selection table:
Type | Capacity KVA | Low Voltage Input | High Voltage Output | No Load Current % | Impedance Voltage % | Weight max Kg | ||
Voltage V | Current | Voltage KV | Current mA | |||||
YD –1.5/50 | 1.5 | 200 | 7.5 | 50 | 30 | 4 | 10 | 22 |
YD –3/50 | 3 | 200 | 15 | 50 | 60 | 4 | 10 | 33 |
YD –6/50 | 6 | 200 | 30 | 50 | 120 | 4 | 10 | 53 |
YD –10/50 | 10 | 200 | 50 | 50 | 200 | 4 | 10 | 79 |
YD–10/100 | 10 | 400 | 25 | 100 | 100 | 4 | 10 | 98 |
Notice:
1) If the maximum voltage is less than 100kv we will offer dry HV transformer for the tester, otherwise we will offer oil HV transformer for the tester
2) The capacity and maximum voltage output could be customized according to the requirements of customer if you can not find the right one in this table
3) The weight listed in the table is HV transformer only
it does not include the weight of main control box.
Please confirm the total weight of the tester with our sales engineer before order
Reliable packaging &Prompt shipping:
Our service:
Main testers:
1.Transformer oil Breakdown voltage Tester ( BDV test kit) series IIJ-II
2. Acidity tester model ACD-3000I
3. Karl Fischer Water content Tester Model TP-6A / model TP-2100
4. Fully automatic Interfacial Tension Analyzer model IT-800
5.Gas-Chromatography transformer oil gas analyzer model DGA2013-1
6. Kinematic Viscosity tester model VST-8 /model VST-2000
7. Flash point tester (open cup) model TPO-3000
8. Flash point tester (close cup) model TPC-3000
9.TAN-DELTA TESTER,10kV Capacitance and Dissipation Factor Test Set model CDEF
10. CT/PT tester model TPVA-404
11.Transformer turn ratio tester model HYG-II
12. Relaying Protection Tester model TPJB-III