GC-2010MD Insulating Oil Dissolved Gas Chromatograph


Application

This Power System Dedicated transformer oil dissolved gas analyzer and Gas Chromatography Analysis System runs by computer automatic control, all-keyboard operation and large-screen liquid crystal display according to the requirements of power system«dissolved gas component determination in insulation oil (chromatography) ,and is characterized by high-precision temperature control, stable and reliable performance, high sensitivity, good reproducibility and so on.The analyzer adopts double-pillar parallel shunt system ,equipped with TCD, double FID and methane conversion oven, and could achieve total analysis of nine components (H2,O2,N2,CH4,C2H2,C2H4,C2H6,CO, CO2)of dissolved gas in insulation oil by one time. 


The analyzer can be employed for internal fault detection of power system oil and gas equipment, cooling medium analysis of hydrogen-cooled generators, impurity analysis of sulfur hexafluoride, the boiler flue gas analysis, gas analysis and environmental monitoring analysis. Due to its employment not only for special analysis, but also for general analysis, the analyzer becomes the most effective gas analytical instrument in petroleum, chemical engineering, mining and other systems.

Features

1. Large-screen LCD display; rich and intuitive displaying content; convenient to set parameters.
2. Unique microcomputer automatic ignition device.
3. Stable and reliable digital zero setting to avoid baseline instability caused by the zero setting of potentiometer.
4. Have analysis acquisition automatic start function to seriously guarantee the synchronization of analysis and acquisition.
5. Sample injector adopts ration card to guarantee accurate sample injection and good repeatability.
6. Intelligent back pullout automatic cooling system with frequency conversion function; with fast cooling speed; achieve real near room temperature operation.
7. Column adopts unique tracking temperature rising to avoid detector contamination caused by rapid heating of column chamber .
8. With gas stopping/leaking protection and prompts functions; maximize the protection for TCD tungsten and column from damage.
9. Temperature control adopts Multichannel Integration Solid-State Relay to make temperature control stable and reliable.
10. Fault self-diagnosis function. At any time to show failure cause and alarm indication.
11. Adopt microcomputer control, keyboard setting, LCD display, with memory function.
12. High performance detector and methanator. The detection capability completely meet the Electric Power Ministry's determination of gas component content in transformer oil.
13. Adopt one injection, second diffluence column with quick analysis speed and good repeatability.
14. Double hydrogen flame design to make low content hydrocarbons and high content CO, CO2 separately detected to avoid mutual interference.
15. Adopt new type column packing material, double column temperature flow to make the C2H2 detection time quicker, sensitivity higher and analysis period shorter.

Technical parameters

1. Column chamber temperature: room temperature +5℃~420℃, temperature control accuracy ±0.1
2. Detection chamber temperature: room temperature+15℃~420℃, temperature control accuracy ±0.1
3. Reburner temperature: room temperature+15℃~420℃, temperature control accuracy ±0.1℃
4.TCD sensitivity, min detection concentration for H2<2ppm, O2<5ppm, N2<10ppm
5.FID detection concentration for hydrocarbons such as methane, ethylene, acetylene<0.1ppm; detection concentration for CO,CO2<2ppm.
6.TCD sensitivity, S>3000mv.ml/mg (benzene) 


Detailed Images

This transformer oil dissolved gas analyzer comes as a complete system.

Related Certificates
Packing & Delivery

Packing: standard export wooden case.
Delivery method: GC2010MD gas chromatography system is sually delivered by air freight, other way are available if need.

Other testers

FAQ

What is the mini order quantity?
MOQ: generally 1 unit/piece/set

What payment methods are supported?
Payment method: By T/T, L/C, Alibaba Trade Assurance etc.
Payment terms: Generally, T/T 40% advanced, the balance paid by T/T when the machine is ready; or 100% irrevocable L/C at sight.

What are the available delivery methods?
Our port location: Chongqing, Shanghai or other main port of China
Delivering to: Worldwide
Delivering method: by sea, by air, by truck, by express, combined transportation

How long is the product date of delivery probably?
Delivery date differs with product type, order quantity, special requirement etc. Usually our big machine delivery date is around 10 ~ 20 days; test equipment or analyzer delivery date is around 5~10 days. Some products have stock, contact us anytime to get more information.

How long is the warranty period?
We warrants the plant supplied under agreed specification against defects in material and workmanship under normal use and service for a period of 2 years after start up of the system.

How is the technical services on the product?
Engineer available to service machinery overseas. If you have any technical question, you are welcome to contact us any time. We will response promptly and answer to your satisfaction. If required and necessary, we can send our engineer to your place to provide technical support.

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Testing Equipment
Categories
Hi~