Insulating Oil GB / T5654-2007 Dielectric Loss And Resistivity Tester TP-6100A
Insulating Oil GB / T5654-2007 Dielectric Loss And Resistivity Tester TP-6100A
Insulating Oil GB / T5654-2007 Dielectric Loss And Resistivity Tester TP-6100A

Insulating Oil GB / T5654-2007 Dielectric Loss And Resistivity Tester TP-6100A

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Chongqing Top Oil Purifier Co., Ltd

Business Type: Association
Main Products: , , ,

Product Details

Product Description

         Insulating Oil Dielectric Loss And Resistivity Tester TP-6100A (Automatic-cleaning)

Power Voltage
AC 220V±10%
Power Frequency
50Hz/60Hz ±1%
Measurement Range
capacitance
5pF~200pF
relative permittivity
1.000~30.000
dielectric dissipation factor
0.00001~100
DC Resistivity
2.5 MΩm~20 TΩm
Measurement Accuracy
capacitance
±(1%reading+0.5pF)
relative permittivity
±1% reading
dielectric dissipation factor
±(1% reading +0.0001)
DC Resistivity
±10% reading
Resolution Ratio
capacitance
0.01pF
relative permittivity
0.001
dielectric dissipation factor
0.00001
Temperature Range
0~125℃
Thermometric Error
±0.5℃
AC testing voltage
500 ~ 2200V adjustable, frequency 50 HZ
DC testing voltage
0 ~ 500V adjustable
Power Dissipation
100w
Boundary Dimension
500mm*360mm*420mm
Weight
22kg

1. Oil cup uses a three-electrode structure in line with GB / T5654-2007, the inter-electrode spacing of 2mm, can eliminate the impacts of stray capacitance and leakage impact on the dielectric loss test results. It has a drain solenoid switch, you can drain all the sample oil in the oil cup without removing the oil cup and rinse the oil cup with sample oil.

2. The instrument uses mid-frequency induction heating, PID temperature control algorithm. This heating method has some advantages, eg, oil cup and heating body non-contact, heating evenly and quickly, also easy to control, thus the temperature strictly controlled within the preset temperature range of error.

3. Internal standard capacitors for SF6 inflatable three-pole impact of capacitors, the capacitor dielectric loss and electrical capacity are not affected by ambient temperature, humidity, etc., to ensure that the instrument is still consistent accuracy after prolonged use.

4.AC Test Power Supply with AC-DC-AC conversion, effectively prevent affecting of the dielectric loss test accuracy for the mains voltage and frequency fluctuations, even the generator generate electricity, the instrument can also run properly.

5. Complete protection. When there is over-voltage, over-current, short-circuit for high-voltage, the instrument can be quickly cut off the voltage and warning. When the temperature sensor fails or is not connected, the instrument will give a warning message.

6.There is a limiting temperature relay amounted in the mid-frequency induction heating furnace, when the temperature exceeds 120 degrees, the relay release, then the heating stop.

7. easy to set the parameters. Temperature setting range 0 ~ 125 ℃, the AC voltage setting range 500 ~ 2200V, the DC voltage setting range 0 ~ 500V.

8.Large-screen LCD display with backlight, clear display. Friendly interface, simply follow the English menu prompt, enter the command, the instrument can be automatically tested. And automatically store and print test results.

9. With real-time clock, test date and time can be saved with the test results, display and print.

10. Empty electrode cup calibration. measuring capacitance and dielectric loss factor of empty electrode cup to determine the status of empty electrode cleaning and assembly of the cup. Calibration data is automatically saved, conducive to calculate the relative permittivity and DC resistivity precisely.
Related Products

     1. Water Content Tester TP-2100

     2. Digital Karl Fischer Water Content Tester TP-6A

     3. Kinematic Viscosity Tester VST-2000

     4. Kinematic Viscosity Tester TPV-8

     5. Kinematic Viscosity Tester VST-3000

     6. Fully Automatic Oil Acidity Tester (6 cups) ACD-3000I

     7. Automatic Surface/Interface Tension Tester IT-800

     8. Automatic Open Cup Flash Point Tester TPO-3000

     9.Closed Cup Flash Point Tester TPC-3000

     10.Digital Open Cup Flash Point Tester TPO-100

11.Digital Closed Cup Flash Point Tester TPC-100

12.Cloud Point & Pour Point Tester PT-2000

13.Multi-functional Vibration Tester VBT-2000

14.Automatic Potentiometric Titrator TP668

15.Petroleum Products Density Tester DST-3000

16.Karl Fischer Volumetric Water Content Titrator TPD

17.Distillation Range Tester DIL-201

18.Online Oil Quality Tester PTT-002

19.Copper Corrosion Tester TP-113

20.Dew Point Tester DPME-P

Packing & Delivery
MOQ
1 Set
Trade Terms
EXW, FOB, CIF, CFR
Payment Terms
T/T, L/C
Port of Loading
Any Port of China
Packing Method
Internaional Standard Wooden Case
Transportation Method
By Sea, By Land, By Air, By Express
Supply Capability
100 Sets/Month

* The warranty period is 24 months from commissioning acceptance date on. After the warranty period is over we provide lifelong maintenance and technical service.
* We guarantee the maintenance time no more than 3 working days and response time within 1 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.

Chongqing TOP Oil Purifier Co., Ltd

Located at Chongqing city--a southwest electromechanical manufacturing center as well as national municipality, Chongqing TOP is a professional leading manufacturer and supplier of oil purifiers and various related testers. Our company consists of departments respectively for technological development, machinery manufacture, instrument manufacture and quality control etc.

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Other Measuring & Analysing Instruments
Categories
Hi~